← Back
Miscellaneous utility property
1 AVENUE
BROOKLYN · BIN 3429155
💬 Discuss this project
0Year Built
—Stories
U9Building Class
M3-1Zoning
0 sfGross Floor Area
0Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Miscellaneous utility property · Owner of record: NYC DEPARTMENT OF SMALL BUSINESS SERVICES · 700,047 sf lot · 0 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionCivilGeneral
Roof21p · 2 filings · 20 docs
Bulkhead8p · 1 filing · 20 docs
Floor 71p · 1 filing · 20 docs
Floor 62p · 1 filing · 20 docs
Floor 55p · 2 filings · 20 docs
Floor 47p · 2 filings · 20 docs
Floor 314p · 2 filings · 20 docs
Floor 216p · 2 filings · 20 docs
Floor 115p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC ECONOMIC DEVELOPMENT CORP2203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AMA CONSULTING ENGINEERS, PC603/07/2024
DATTNER ARCHITECTS209/12/2023
SEVERUD ASSOCIATES307/20/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DOMANI CONSULTING1103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DELTA TESTING LABS687803/07/2024
Building Lifecycle
All (65)Filed (11)Objection (24)Special Inspection (30)
03/18/2024
Special inspection requirement — Standpipe Systems
RICHARD GREENWALD
03/18/2024
Special inspection requirement — Sprinkler Systems
RICHARD GREENWALD
03/07/2024
Filed — Alteration
B00661213-P1
01/23/2024
Special inspection requirement — Standpipe Systems
RICHARD GREENWALD
01/23/2024
Special inspection requirement — Sprinkler Systems
RICHARD GREENWALD
09/12/2023
Filed — New Building
Herewith filing SOE
B00616429-P3
09/12/2023
Objection raised — Other
09/12/2023
Objection resolved — Addressed
08/17/2023
Special inspection requirement — Energy Code Compliance Inspections
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Lowest Floor Elevation
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Air barrier continuity plan testing
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Protection of exposed foundation insulation
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Air barrier — testing
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Fenestration areas
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Air barrier - visual inspection
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Fenestration air leakage
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Vestibules
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Fire-Resistance Rated Construction
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Sprayed fire-resistant materials
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
RICHARD GREENWALD
08/17/2023
Special inspection requirement — Insulation placement and R values
RICHARD GREENWALD
08/04/2023
Special inspection requirement — Structural Steel - Welding
RICHARD GREENWALD
08/04/2023
Special inspection requirement — Concrete - Precast
RICHARD GREENWALD
08/04/2023
Special inspection requirement — Final
RICHARD GREENWALD
08/04/2023
Special inspection requirement — Structural Cold-Formed Steel
RICHARD GREENWALD
08/04/2023
Special inspection requirement — Structural Steel - High Strength Bolting
RICHARD GREENWALD
08/04/2023
Special inspection requirement — Masonry
RICHARD GREENWALD
08/04/2023
Special inspection requirement — Structural Steel - Details
RICHARD GREENWALD
08/04/2023
Special inspection requirement — Concrete – Prestressed
RICHARD GREENWALD
08/04/2023
Special inspection requirement — Concrete - Cast-In-Place
RICHARD GREENWALD
07/24/2023
Objection raised — Other
07/24/2023
Objection resolved — Addressed
07/20/2023
Filed — New Building
Herewith filing SOE
B00616429-P2
06/29/2023
Objection resolved — Addressed
06/29/2023
Objection resolved — Addressed
06/28/2023
Objection raised — Other
06/28/2023
Objection raised — Other
06/19/2023
Special inspection requirement — Structural Cold-Formed Steel
RICHARD GREENWALD
03/20/2023
Objection resolved — Addressed
03/08/2023
Objection resolved — Addressed
03/06/2023
Objection raised — Other
02/27/2023
Objection resolved — Addressed
10/12/2022
Objection resolved — Addressed
10/12/2022
Objection resolved — Addressed
02/15/2022
Objection resolved — Addressed
02/15/2022
Objection resolved — Addressed
02/09/2022
Objection resolved — Addressed
02/08/2022
Objection raised — Other
02/08/2022
Objection raised — Other
02/08/2022
Objection raised — Energy
02/08/2022
Objection raised — Other
01/25/2022
Filed — Alteration
B00661213-I1
12/29/2021
Filed — New Building
Herewith filing SOE
B00616429-S6
12/29/2021
Filed — New Building
Herewith filing SOE
B00616429-S5
12/28/2021
Filed — Alteration
B00645197-I1
12/23/2021
Objection raised — Fire_Protection
12/23/2021
Objection raised — Zoning
Latest 60 of 65 events.
Nothing on file for this building.
1 project · most recent 09/12/2023
Air Conditioning Systems Associated Ducts and Piping Cooling Towers Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/12/2023——Air Conditioning Systems, Associated Ducts and Piping, Cooling Towers, Ventilation Systems
Cooling
Daikin RWEYQ72PCYC 205,000 BTU · Vrf Outdoor ×21
FXMQ24PVJU 24,000 BTU · Vrf Indoor ×4
RPS110D 1,200,000 BTU · Rooftop Unit ×4
WCCH2072 74,000 BTU · Wshp ×7
FXMQ54BVJU 74,000 BTU · Vrf Indoor ×2
SWP033HLS 414,000 BTU · Wshp ×2
WCCH5030 29,000 BTU · Wshp ×4
WCCH5060 56,000 BTU · Wshp ×2
DPSA052 66,000 BTU · Doas ×1
FBQ36PVJU 36,000 BTU · Split System ×1
MPSA07D 1,000,000 BTU · Rooftop Unit ×1
WCCH5048 49,000 BTU · Wshp ×2
WCCH5036 36,000 BTU · Wshp ×7
WCCH1220 120,000 BTU · Wshp ×3
WCCH2096 96,000 BTU · Wshp ×2
WCCH5024 30,000 BTU · Wshp ×1
Ventilation
Daikin DPS020A 183,000 BTU · Rooftop Unit ×2
Cooling Tower
Marley NC840MLN2 65,890 CFM · Cooling Tower ×2
1 project · most recent 09/12/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
09/12/2023——Gas, Storm, Water/Sanitary
1 project · most recent 09/12/2023
Steel Concrete
FiledStatusContractorScope
09/12/2023——Steel, Concrete
▾Special Inspection Requirements (DOB NOW) — 61
DateRequirementInspectorRole
03/18/2024Sprinkler SystemsRICHARD GREENWALDspecial
03/18/2024Standpipe SystemsRICHARD GREENWALDspecial
01/23/2024Standpipe SystemsRICHARD GREENWALDspecial
01/23/2024Sprinkler SystemsRICHARD GREENWALDspecial
08/17/2023Lowest Floor ElevationRICHARD GREENWALDprogress
08/17/2023Insulation placement and R valuesRICHARD GREENWALDenergy_progress
08/17/2023Fenestration and door U-factor and product ratingsRICHARD GREENWALDenergy_progress
08/17/2023Air barrier — testing RICHARD GREENWALDenergy_progress
08/17/2023Protection of exposed foundation insulationRICHARD GREENWALDenergy_progress
08/17/2023Fenestration areasRICHARD GREENWALDenergy_progress
08/17/2023Air barrier continuity plan testingRICHARD GREENWALDenergy_progress
08/17/2023Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)RICHARD GREENWALDspecial
08/17/2023Wall Panels, Curtain Walls, and VeneersRICHARD GREENWALDspecial
08/17/2023Energy Code Compliance InspectionsRICHARD GREENWALDprogress
08/17/2023Fire-Resistance Rated ConstructionRICHARD GREENWALDprogress
08/17/2023Air barrier - visual inspectionRICHARD GREENWALDenergy_progress
08/17/2023Fenestration air leakageRICHARD GREENWALDenergy_progress
08/17/2023VestibulesRICHARD GREENWALDenergy_progress
08/17/2023Fire-Resistant Penetrations and JointsRICHARD GREENWALDspecial
08/17/2023Sprayed fire-resistant materialsRICHARD GREENWALDspecial
08/04/2023Concrete - PrecastRICHARD GREENWALDspecial
08/04/2023FinalRICHARD GREENWALDprogress
08/04/2023Structural Steel - WeldingRICHARD GREENWALDspecial
08/04/2023MasonryRICHARD GREENWALDspecial
08/04/2023Structural Cold-Formed SteelRICHARD GREENWALDspecial
Latest 25 of 61.
▾Documents — 98 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/31/2026B00616429-I1Request digital key ↗
08/31/2026B00616429-S3Request digital key ↗
08/31/2026B00616429-S5Request digital key ↗
Showing 3 of 12 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026B00616429-P3Open ↗
08/13/2026B00616429-I1Open ↗
▸Seals & Professional Certifications59
▸DOB NOWProgress Inspector Seal & Signature26
08/31/2026B00616429-S3Open ↗
08/28/2026B00616429-P3Open ↗
08/28/2026B00616429-P3Open ↗
Showing 3 of 26 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature21
09/01/2026B00661213-P1Open ↗
09/01/2026B00661213-P1Open ↗
08/31/2026B00616429-S1Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/31/2026B00616429-I1Open ↗
08/31/2026B00616429-S3Open ↗
08/31/2026B00645197-I1Open ↗
Showing 3 of 12 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026B00616429-P3Open ↗
08/13/2026B00616429-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/31/2026B00616429-I1Open ↗
08/13/2026B00616429-P3Open ↗
▸Inspections & Test Reports3
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00616429-S1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026B00616429-S1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026B00616429-S1Open ↗
▸Approvals, Objections & Sign-offs12
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)12
08/13/2026B00616429-P3Open ↗
08/13/2026B00616429-S3Open ↗
08/13/2026B00616429-S7Open ↗
Showing 3 of 12 on file for this type
▸Other Documents6
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B00616429-P3Open ↗
08/13/2026B00616429-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/31/2026B00616429-I1Open ↗
08/13/2026B00616429-P3Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026B00616429-I1Open ↗
08/13/2026B00616429-P3Open ↗