← Back
Condo, residential unit in elevator building
Spencer Condominium
1 EAST 62 STREET · Upper East Side-Carnegie Hill · BIN 1041003
💬 Discuss this project
1905Year Built
6Stories
R4Building Class
R8BZoning
17,477 sfGross Floor Area
12Units
Rent Stabilized6 Open Violations ▸FISP: SAFE
Condo, residential unit in elevator building · 4,217 sf lot · 4.14 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof1p · 1 filing · 6 docs
Floor 517p · 2 filings · 20 docs
Floor 42p · 1 filing · 13 docs
Floor 3
Floor 2
Floor 1
Mezzanine1p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MB CONSTRUCTION DESIGN SERVICES L1707/08/2026
AMIRIAN GROUP1207/08/2026
PENMARK REALTY303/22/2026
SPENCER CONDOMINIUM2703/22/2026
SPENCER CONDO PENMARK REA203/22/2026
SPECER CONDO103/22/2026
PENN MARK REALTY103/22/2026
HALSTEAD MANAGEMENT203/21/2026
DYNAMIC BRIDGES LLC103/21/2026
SPENCER CONDO C O PENMARK REALTY303/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FAVIO MARIA BARRIONUEVO1003/21/2026
BODNAR ARCHITECTURE P C603/21/2026
RIGHT WAY SERVICES NYC203/21/2026
THE GREEN STUDIO103/21/2026
HAIDER ENGINEERING, P.E.203/21/2026
SYNERGY BUILDING CONSULTANTS103/21/2026
HAIDER ENGINEERING P E203/21/2026
MILLENNIUM DESIGNS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DYNAMIX SCAFFOLD GROUP LLGeneral Contractor803/21/2026
AM BUILDING RESTORATION*General Contractor707/08/2026
MB CNSTRT & DSGN SVCES LLGeneral Contractor407/08/2026
EVEREST SCAFFOLDING INCGeneral Contractor403/21/2026
GIBCO CONSTRUCTION CORPGeneral Contractor407/08/2026
786 A&S.CONSTRUCTION CORPGeneral Contractor303/21/2026
ANDAMIO SCAFFOLDING LLCGeneral Contractor303/21/2026
DYNAMIC INSTALLATION CORP.General Contractor303/21/2026
WEST VILLAGE GC LLCGeneral Contractor307/08/2026
MICHAEL BAPTISTEElectrical203/21/2026
WILLIAM C. GERAKARIS P&HPlumbing107/08/2026
CARLO COPPOLAElectrical103/21/2026
IRVING BAPTISTEElectrical103/21/2026
JAROSLAW KURACHElectrical103/21/2026
IMPACT PLUMBING INCPlumbing107/08/2026
BENJAMIN DREBINElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MARCH CHADWICK, ARCHITECT2253107/29/2024
JOSE M. LANDAURO3500106/10/2024
STRUCT. ENGINEERING INTEG4174204/22/2024
DOMANI INSPECTION SERVICE843304/19/2024
MICHAEL ZENREICH ARCHITEC1724110/04/2023
Building Lifecycle
All (146)Filed (18)Permit Issued (23)Signed Off (7)Facade (FISP) (13)Violation (41)Inspection (4)Objection (14)Special Inspection (26)
04/23/2026
Signed off — Alteration
M00931002-I1
10/06/2025
Permit issued — General Construction
M01010156-I1-GC
09/12/2025
Permit issued — Protection and Mechanical Methods
M01283461-I1-PMM
09/11/2025
Filed — Alteration
Installation of temporary beta max hoist as per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01283461-I1
06/04/2025
Violation issued (HPD, closed)
A
04/30/2025
Permit issued — General Construction
M01052045-I1-GC
04/10/2025
Permit issued — Supported Scaffold
M01032622-I1-SF
04/10/2025
Permit issued — Supported Scaffold
M01032622-I1-SH
03/07/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/22/2024
Violation issued (HPD, closed)
I
11/06/2024
Signed off — Alteration
M00935897-I1
10/23/2024
Permit issued — Mechanical Systems
M01010156-S2-MS
09/13/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/12/2024
Permit issued — General Construction
M01052045-I1-GC
08/23/2024
Objection resolved — Addressed
08/08/2024
Objection raised — Admin
07/29/2024
Filed — Alteration
SUBSEQUENT DOCUMENT FOR HVAC INSTALLATION WORK RELATED TO APARTMENT 5B INTERIOR RENOVATION.
M01010156-S2
06/11/2024
Permit issued — General Construction
M00935897-I1-GC
06/10/2024
Filed — Alteration
Filing for Terrace Waterproofing Repairs work that includes removal of existing terrace floor tiles, replacement of wood decking and waterproofing repairs to water table at 5th floor, etc. as shown on drawings filed herewith. No change in use, egress or o
M01052045-I1
06/10/2024
Permit issued — Plumbing
M01010156-S1-PL
06/10/2024
Special inspection requirement — Tenant Protection Plan Compliance
JOSE LANDAURO
05/24/2024
Permit issued — General Construction
M01010156-I1-GC
05/23/2024
Special inspection requirement — Energy Code Compliance Inspections
RONNY BECKER
05/23/2024
Special inspection requirement — Fire-Resistance Rated Construction
RONNY BECKER
05/23/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Chris Yiu
05/23/2024
Special inspection requirement — Interior lighting power
RONNY BECKER
05/23/2024
Special inspection requirement — Lighting controls
RONNY BECKER
05/23/2024
Special inspection requirement — Lighting in dwelling units
RONNY BECKER
05/23/2024
Special inspection requirement — Final
RONNY BECKER
05/15/2024
Special inspection requirement — Final
JOSE LANDAURO
05/07/2024
Signed off — Alteration
Installation of two air handling units in vestibule and bedroom. No change of occupancy use or egress.
M00935902-I1
05/06/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Chris Yiu
05/01/2024
Special inspection requirement — Mechanical Systems
JOHN MCMONAGLE
05/01/2024
Special inspection requirement — Energy Code Compliance Inspections
Kian Moozar
05/01/2024
Special inspection requirement — Final
Kian Moozar
04/22/2024
Filed — Alteration
SUBSEQUENT DOCUMENT FOR HVAC INSTALLATION WORK RELATED TO APARTMENT 5B INTERIOR RENOVATION.
M01010156-P1
04/22/2024
Special inspection requirement — Interior lighting power
RONNY BECKER
04/22/2024
Special inspection requirement — Fire-Resistance Rated Construction
RONNY BECKER
04/22/2024
Special inspection requirement — Final
RONNY BECKER
04/22/2024
Special inspection requirement — Energy Code Compliance Inspections
RONNY BECKER
04/22/2024
Special inspection requirement — Lighting in dwelling units
RONNY BECKER
04/22/2024
Special inspection requirement — Lighting controls
RONNY BECKER
04/19/2024
Filed — Alteration
Installation of two air handling units in vestibule and bedroom. No change of occupancy use or egress.
M00935902-P1
04/18/2024
Special inspection requirement — Final
Kian Moozar
04/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Kian Moozar
04/18/2024
Special inspection requirement — Mechanical Systems
JOHN MCMONAGLE
04/09/2024
Filed — Alteration
INSTALLATION OF 300 PSF SIDEWALK SHED AND PIPE SCAFFOLDING AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01032622-I1
04/09/2024
Signed off — Alteration
Removal and Replacement of plumbing fixtures and appliances in kitchen and bathrooms at 4AB on the fourth floor. No change in occupancy use or egress.
M00816307-I1
04/09/2024
Permit issued — Sidewalk Shed
M01032622-I1-SF
04/09/2024
Permit issued — Sidewalk Shed
M01032622-I1-SH
04/05/2024
Signed off — Alteration
Construction of new walls, floors and dropped ceilings. No change in occupancy use or egress.
M00674156-S1
04/02/2024
Filed — Alteration
SUBSEQUENT DOCUMENT FOR HVAC INSTALLATION WORK RELATED TO APARTMENT 5B INTERIOR RENOVATION.
M01010156-S1
04/02/2024
Objection resolved — Addressed
04/02/2024
Objection resolved — Addressed
04/02/2024
Objection resolved — Addressed
04/02/2024
Objection resolved — Addressed
03/14/2024
Objection raised — Inspections
03/14/2024
Objection raised — Scope
03/14/2024
Objection raised — Accessibility
03/14/2024
Objection raised — Energy
Latest 60 of 146 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMB CNSTRT & DSGN SVCES LL10/06/2025
DOB NOWProtection and Mechanical MethodsPermit IssuedAM BUILDING RESTORATION*09/12/2025
DOB NOWGeneral ConstructionPermit IssuedAM BUILDING RESTORATION*04/30/2025
DOB NOWSupported ScaffoldPermit IssuedDYNAMIX SCAFFOLD GROUP LL04/10/2025
DOB NOWSupported ScaffoldPermit IssuedDYNAMIX SCAFFOLD GROUP LL04/10/2025
DOB NOWMechanical SystemsPermit IssuedMB CNSTRT & DSGN SVCES LL10/23/2024
DOB NOWGeneral ConstructionPermit IssuedAM BUILDING RESTORATION*09/12/2024
DOB NOWGeneral ConstructionSigned-offWEST VILLAGE GC LLC06/11/2024
DOB NOWPlumbingPermit IssuedWILLIAM C. GERAKARIS P&H06/10/2024
DOB NOWGeneral ConstructionPermit IssuedMB CNSTRT & DSGN SVCES LL05/24/2024
DOB NOWSidewalk ShedPermit IssuedDYNAMIX SCAFFOLD GROUP LL04/09/2024
DOB NOWSidewalk ShedPermit IssuedDYNAMIX SCAFFOLD GROUP LL04/09/2024
DOB NOWMechanical SystemsSigned-offGIBCO CONSTRUCTION11/17/2023
DOB NOWGeneral ConstructionSigned-offWEST VILLAGE GC LLC10/30/2023
DOB NOWGeneral ConstructionSigned-offMB CNSTRT & DSGN SVCES LL09/13/2023
DOB NOWGeneral ConstructionSigned-offGIBCO CONSTRUCTION04/03/2023
DOB NOWPlumbingSigned-offIMPACT PLUMBING INC02/24/2023
DOB NOWGeneral ConstructionSigned-offGIBCO CONSTRUCTION01/06/2023
DOB NOWGeneral ConstructionSigned-off786 A&S.CONSTRUCTION CORP09/30/2022
DOB NOWSupported ScaffoldSigned-offANDAMIO SCAFFOLDING LLC09/14/2021
DOB NOWSupported ScaffoldSigned-offEVEREST SCAFFOLDING INC09/09/2021
DOB NOWSupported ScaffoldSigned-offEVEREST SCAFFOLDING INC09/11/2020
DOB NOWSupported ScaffoldPermit IssuedDYNAMIC INSTALLATION CORP07/31/2018
BISOTISSUEDA W R GROUP INC06/25/2021
BISOTISSUEDA W R GROUP INC03/17/2021
BISOTISSUEDA W R GROUP INC03/27/2020
BISOTISSUEDA W R GROUP INC02/07/2020
BISOTISSUEDA W R GROUP INC09/20/2018
BISEQISSUEDDYNAMIC INSTALLATION CORP.09/14/2018
BISOTISSUEDA W R GROUP INC08/28/2018
BISEQISSUEDDYNAMIC INSTALLATION CORP.09/20/2017
BISPLISSUEDADRIATIC PLBG & HTG CORP11/20/2015
BISPLISSUEDPRECISION PLBG SVCS., INC09/10/2015
BISOTISSUEDAM BUILDING MAINTENANCE C07/31/2013
BISOTISSUEDAM BUILDING MAINTENANCE C08/06/2012
BISEQISSUEDDYNAMIC BRIDGE & SCAFFOLD05/24/2012
BISOTISSUEDAM BUILDING MAINTENANCE*04/26/2012
BISOTISSUEDAM BUILDING MAINTENANCE*04/26/2012
BIS—ISSUEDSCORCIA & ASSOCIATES INC04/17/2012
BIS—ISSUEDSCORCIA & ASSOCIATES INC12/07/2011
+ 18 more permits on file
1 project · most recent 07/29/2024
Gas Water/Sanitary
FiledStatusContractorScope
07/29/2024Permit IssuedWILLIAM C. GERAKARIS P&HGas, Water/Sanitary
9 projects · most recent 09/08/2026
General Wiring
FiledStatusContractorScope
09/08/2026CompleteAXCEL ELECTRIC CO., INC.—
05/12/2026CompleteAXCEL ELECTRIC CO., INC.—
06/06/2024Permit IssuedBELMONT ELECTRICAL, INCGeneral Wiring
04/10/2024Permit IssuedRICHARD NEU—
10/26/2023CompleteTOP NOTCH ELECTRIC INCGeneral Wiring
03/15/2023Permit IssuedCONTACT PLUS ELEC'L CORPGeneral Wiring
09/28/2021CompleteAXCEL ELECTRIC CO., INC.—
09/18/2018CompleteAXCEL ELECTRIC CO., INC.—
02/23/2018CompleteGOTHAM WIRING LICENSEDGeneral Wiring
1 project · most recent 04/09/2024
Scaffold Sidewalk Shed
FiledStatusContractorScope
04/09/2024Permit IssuedDYNAMIX SCAFFOLD GROUP LLScaffold, Sidewalk Shed
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
03/07/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/13/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/07/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/01/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
06/10/2024Tenant Protection Plan ComplianceJOSE LANDAUROspecial
05/23/2024Energy Code Compliance InspectionsRONNY BECKERprogress
05/23/2024Fire-Resistance Rated ConstructionRONNY BECKERprogress
05/23/2024Fire-Resistant Penetrations and JointsChris Yiuspecial
05/23/2024Interior lighting powerRONNY BECKERenergy_progress
05/23/2024Lighting controlsRONNY BECKERenergy_progress
05/23/2024Lighting in dwelling unitsRONNY BECKERenergy_progress
05/23/2024FinalRONNY BECKERprogress
05/15/2024FinalJOSE LANDAUROprogress
05/06/2024Fire-Resistant Penetrations and JointsChris Yiuspecial
05/01/2024Mechanical SystemsJOHN MCMONAGLEspecial
05/01/2024Energy Code Compliance InspectionsKian Moozarprogress
05/01/2024FinalKian Moozarprogress
04/22/2024Interior lighting powerRONNY BECKERenergy_progress
04/22/2024Fire-Resistance Rated ConstructionRONNY BECKERprogress
04/22/2024FinalRONNY BECKERprogress
04/22/2024Energy Code Compliance InspectionsRONNY BECKERprogress
04/22/2024Lighting in dwelling unitsRONNY BECKERenergy_progress
04/22/2024Lighting controlsRONNY BECKERenergy_progress
04/18/2024FinalKian Moozarprogress
04/18/2024Energy Code Compliance InspectionsKian Moozarprogress
04/18/2024Mechanical SystemsJOHN MCMONAGLEspecial
12/11/2023FinalTheodore Bodnarprogress
11/30/2023Finalwai man chowprogress
02/09/2022FinalTheodore Bodnarprogress
Latest 25 of 26.
▾Documents — 231 on file (BIS + DOB NOW)
▸Plans & Drawings18
▸DOB NOWPlans/Sketch17
09/06/2026M00055104-I1Request digital key ↗
09/06/2026M00055104-P1Request digital key ↗
09/01/2026M00674156-I1Request digital key ↗
Showing 3 of 17 on file for this type
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/04/2026M00395295-I1Request digital key ↗
▸Applications & Permits51
▸BISPLAN / WORK APPROVAL APPLICATION21
06/10/2025110220494Open ↗
06/10/2025103115219Open ↗
03/23/2020123435979Open ↗
Showing 3 of 21 on file for this type
▸BISWORK PERMIT APPLICATION17
03/27/2020123435979Open ↗
02/07/2020123435979Open ↗
09/24/2018123435979Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWLPC Approval/Permit13
08/13/2026M00935902-P1Open ↗
08/13/2026M01052045-I1Open ↗
08/13/2026M00816307-I1Open ↗
Showing 3 of 13 on file for this type
▸Seals & Professional Certifications61
▸DOB NOWDPL-1: Design Professional Seal & Signature18
09/06/2026M00055104-I1Open ↗
09/06/2026M00055104-P1Open ↗
09/04/2026M00395295-I1Open ↗
Showing 3 of 18 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION14
02/28/2018123435979Open ↗
09/22/2017123123734Open ↗
10/01/2015120948528Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
09/01/2026M01052045-I1Open ↗
08/29/2026M00674156-S1Open ↗
08/28/2026M00935902-P1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/01/2026M01052045-I1Open ↗
08/28/2026M00935902-P1Open ↗
08/28/2026M01010156-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
09/22/2017123123734Open ↗
05/25/2012121007178Open ↗
10/14/2010120496766Open ↗
▸BISProfessional and Owner Certification (POC3)2
10/14/2010120496766Open ↗
10/14/2010120496766Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
05/25/2012121007178Open ↗
10/14/2010120496766Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
09/22/2017123123734Open ↗
11/17/2015140430406Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
11/17/2015140430406Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/17/2015140430406Open ↗
▸Trade Schedules & Equipment9
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
01/09/2016140430406Open ↗
01/08/2016140430406Open ↗
07/22/2015110220494Open ↗
▸BISSELF-CERT PLUMBING NOTICE3
12/21/2015140430406Open ↗
10/30/2015110220494Open ↗
10/30/2015110220494Open ↗
▸BISSCHEDULE B - PLUMBING2
11/17/2015140430406Open ↗
03/20/2008110220494Open ↗
▸BISEQUIPMENT USE APPLICATION-PERMIT1
10/14/2010120496766Open ↗
▸Safety & Tenant Protection3
▸BISTenant Protection Plan and Notes2
02/28/2018123435979Open ↗
09/22/2017123123734Open ↗
▸DOB NOWTenant Protection Plan1
09/04/2026M00395295-I1Open ↗
▸Environmental & Asbestos24
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
09/06/2026M00055104-P1Open ↗
09/06/2026M00055104-I1Open ↗
08/29/2026M00935897-I1Open ↗
Showing 3 of 12 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'5
02/13/2012120948528Open ↗
02/13/2012120948519Open ↗
10/14/2010120496766Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
08/13/2018123435979Open ↗
03/14/2018123435979Open ↗
11/17/2015140430406Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
05/25/2012121007178Open ↗
03/03/2008110106787Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/29/2026M00935902-I1Open ↗
08/13/2026M00816307-I1Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
02/28/2018123435979Open ↗
10/01/2015120948528Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
08/01/2022123435979Open ↗
11/17/2015140430406Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
10/01/2015120948528Open ↗
01/25/2013120948519Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
08/01/2022123435979Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
11/17/2015140430406Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
08/01/2022123435979Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
08/01/2022123435979Open ↗
08/01/2022123435979Open ↗
11/17/2015140430406Open ↗
▸Approvals, Objections & Sign-offs22
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST6
08/02/2022123435979Open ↗
10/01/2015120948528Open ↗
03/12/2013120948519Open ↗
Showing 3 of 6 on file for this type
▸BISLANDMARKS APPROVAL6
06/05/2020123435979Open ↗
06/04/2020123435979Open ↗
11/17/2015140430406Open ↗
Showing 3 of 6 on file for this type
▸BISADMINISTRATIVE OBJECTIONS6
05/25/2012121007178Open ↗
02/13/2012120948528Open ↗
02/13/2012120948519Open ↗
Showing 3 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
01/25/2013120948519Open ↗
03/21/2012120948519Open ↗
▸BISSUPERSEDING LETTER1
10/02/2015110220494Open ↗
▸BISFINAL1
08/01/2022123435979Open ↗
▸Cost, Insurance & Ownership10
▸BISCOST AFFIDAVIT10
08/01/2022123435979Open ↗
08/13/2018123435979Open ↗
02/28/2018123435979Open ↗
Showing 3 of 10 on file for this type
▸Filing & Intake Forms17
▸BISADDITIONAL INFORMATION8
06/05/2020123435979Open ↗
06/04/2020123435979Open ↗
05/14/2019123435979Open ↗
Showing 3 of 8 on file for this type
▸BISEFILING COVER SHEET6
02/28/2018123435979Open ↗
09/22/2017123123734Open ↗
05/25/2012121007178Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
11/17/2015140430406Open ↗
03/20/2008110220494Open ↗
▸BISBOROUGH INTAKE FORM1
03/23/2020123435979Open ↗
▸Other Documents4
▸DOB NOWWaiver Document3
08/13/2026M00674156-S1Open ↗
08/13/2026M00674156-P1Open ↗
08/13/2026M00674156-I1Open ↗
▸BISSupporting Document: Fee Exempt1
05/05/2010110220494Open ↗