| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/16/2026 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Lg ZRNU243MAAA 24,200 BTU · Vrf Indoor ×5 ZRNU053TRAA 5,500 BTU · Vrf Indoor ×4 ZRNU073TRAA 7,500 BTU · Vrf Indoor ×4 ZRNU073MAAA 7,500 BTU · Vrf Indoor ×3 ZRNU123TRAA 12,300 BTU · Vrf Indoor ×3 ZRNU153TQAA 15,400 BTU · Vrf Outdoor ×3 ZRNU093TRAA 9,600 BTU · Vrf Indoor ×2 ZRNU243SKSA 27,300 BTU · Vrf Outdoor ×2 ZRNU303SRAA 32,000 BTU · Vrf Indoor ×2 ARDR-112-10A-1-E2 82,600 BTU · Vrf Outdoor ×1 ARNU763B8A4 88,900 BTU · Vrf Indoor ×1 ZRNU183MAAA 19,100 BTU · Vrf Indoor ×1 Thermotech TTRTU1-E.102-13-3T 39,600 BTU · Rooftop Unit ×2 Ventilation Greenheck CUE-100HP-VG 505 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/16/2026 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/16/2026 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/24/2019 | Complete | TUXEDO ELEC'L CONTR'G INC | — |
| 06/04/2018 | Complete | BOROWIDE ELECT'L CONTR'S | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/16/2026 | — | — | Steel, Concrete |
| Owner | Filings | Most Recent |
|---|---|---|
| WIFI CONSTRUCTION | 8 | 07/08/2026 |
| GOTHAM BUILDERS GROUP,LL | 5 | 03/22/2026 |
| PUMA CONSTRUCTION | 8 | 03/22/2026 |
| GOTHAM BUILDERS INC | 1 | 03/22/2026 |
| OCHER REALTY | 21 | 03/22/2026 |
| PROJECT BUILDERS GROUP | 2 | 03/21/2026 |
| HKS CONSTRUCTION | 2 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/15/2024 | $6.0M | — | — → — | $705/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| E2 ENGINEERS | 2 | 06/16/2026 |
| EMTEC CONSULTING ENGINEERS, DPC | 3 | 09/05/2025 |
| EDGE + CO. | 1 | 02/03/2025 |
| RYBAK ARCHITECTS, P.C. | 3 | 09/09/2021 |
| ASIF JAMIL, RA | 2 | 03/02/2020 |
| PAUL PERDEK, PROF. ENG. PLLC | 1 | 12/06/2019 |
| DOOLING & COMPANY ARCHITECTS | 1 | 06/07/2018 |
| Representative | Filings | Most Recent |
|---|---|---|
| KD DESIGNS | 2 | 03/21/2026 |
| AE DESIGN SOLUTION | 4 | 03/21/2026 |
| W J PROFESSIONAL EXPEDITING COMPANY | 10 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| EVEREST SCAFFOLDING INC | General Contractor | 6 | 07/08/2026 |
| RYBAK ARCHITECTS P C | General Contractor | 5 | 03/22/2026 |
| WIFI CONSTRUCTION LLC | General Contractor | 4 | 07/08/2026 |
| PUMA CONSTRUCTION CORP | General Contractor | 2 | 03/21/2026 |
| PELHAM PLUMBING & HTG CORP | Plumbing | 2 | 03/22/2026 |
| MEGA PLBG CORP | Fire Protection | 1 | 07/08/2026 |
| NICE PLUMBING CORP | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| RYBAK ARCHITECTS, P.C. | 4044 | 3 | 09/09/2021 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Signed-off | REAL PLUMBING CORP | 08/18/2021 |
| DOB NOW | Sprinklers | Signed-off | NICE PLUMBING CORP | 08/07/2021 |
| DOB NOW | Mechanical Systems | Signed-off | INTERBORO SIGN & ELECTRIC | 08/03/2021 |
| DOB NOW | Supported Scaffold | Signed-off | WIFI CONSTRUCTION LLC | 03/04/2020 |
| DOB NOW | Supported Scaffold | Signed-off | WIFI CONSTRUCTION LLC | 01/30/2020 |
| DOB NOW | Sidewalk Shed | Signed-off | EVEREST SCAFFOLDING INC | 12/06/2019 |
| DOB NOW | Sidewalk Shed | Signed-off | EVEREST SCAFFOLDING INC | 07/24/2019 |
| DOB NOW | Sidewalk Shed | Signed-off | EVEREST SCAFFOLDING INC | 07/27/2018 |
| DOB NOW | Sidewalk Shed | Signed-off | EVEREST SCAFFOLDING INC | 06/09/2018 |
| BIS | PL | ISSUED | MASTER 2 PLBG & HTG INC | 11/09/2020 |
| BIS | — | ISSUED | PUMA CONSTRUCTION CORP | 07/27/2020 |
| BIS | — | ISSUED | PUMA CONSTRUCTION CORP | 10/16/2019 |
| BIS | — | ISSUED | PUMA CONSTRUCTION CORP | 10/15/2019 |
| BIS | EQ | ISSUED | PUMA CONSTRUCTION CORP | 10/15/2019 |
| BIS | PL | ISSUED | MASTER 2 PLBG & HTG INC | 04/19/2019 |
| BIS | — | ISSUED | PUMA CONSTRUCTION CORP | 04/08/2019 |
| BIS | — | ISSUED | PUMA CONSTRUCTION CORP | 03/28/2019 |
| BIS | — | ISSUED | PUMA CONSTRUCTION CORP | 10/19/2018 |
| BIS | EQ | ISSUED | PUMA CONSTRUCTION CORP | 10/19/2018 |
| BIS | EQ | ISSUED | GOTHAM BUILDERS GROUP, LL | 07/02/2018 |
| BIS | — | ISSUED | GOTHAM BUILDERS GROUP, LL | 07/02/2018 |
| BIS | PL | ISSUED | MASTER 2 PLBG & HTG INC | 11/15/2017 |
| BIS | — | ISSUED | GOTHAM BUILDERS GROUP, LL | 07/27/2017 |
| BIS | EQ | ISSUED | GOTHAM BUILDERS GROUP, LL | 07/26/2017 |
| BIS | — | ISSUED | GOTHAM BUILDERS GROUP, LL | 04/28/2017 |
| BIS | — | ISSUED | GOTHAM BUILDERS GROUP, LL | 10/25/2016 |
| BIS | EQ | ISSUED | GOTHAM BUILDERS GROUP, LL | 06/15/2016 |
| BIS | — | ISSUED | GOTHAM BUILDERS GROUP, LL | 06/15/2016 |
| BIS | EQ | ISSUED | HKS CONSTRUCTION CORP | 06/05/2015 |
| BIS | — | ISSUED | KINGS COUNTY DEMOLITION I | 05/15/2015 |
| BIS | EQ | ISSUED | KINGS COUNTY DEMOLITION I | 05/12/2015 |
| BIS | PL | ISSUED | M.WOLF PLUMBING HEATING | 09/01/2000 |
| BIS | BL | ISSUED | M. WOLF PLUMBING HEATING | 08/23/2000 |
| BIS | PL | ISSUED | M WOL PLG HTNG CORP | 08/30/1999 |
| BIS | BL | ISSUED | M. WOLF PLUMBING & HEATING | 08/30/1999 |
| Date | Type | Result | Report |
|---|---|---|---|
| 09/09/2021 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 09/07/2021 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 09/03/2021 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 08/18/2021 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 04/27/2026 | Structural Stability – Alterations of existing buildings | — | special |
| 04/27/2026 | Structural Steel - Details | — | special |
| 04/27/2026 | Structural Steel - Welding | — | special |
| 04/27/2026 | Concrete - Precast | — | special |
| 04/27/2026 | Final | — | progress |
| 04/27/2026 | Structural Steel - High Strength Bolting | — | special |
| 04/27/2026 | Post-installed Anchors | — | special |
| 11/18/2025 | HVAC-R and service water heating system controls | — | energy_progress |
| 11/18/2025 | HVAC-R and service water heating equipment | — | energy_progress |
| 07/21/2025 | Shutoff dampers | — | energy_progress |
| 07/21/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 07/21/2025 | Post-installed Anchors | — | special |
| 07/21/2025 | Energy Code Compliance Inspections | — | progress |
| 07/21/2025 | Maintenance information | — | energy_progress |
| 07/21/2025 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 07/21/2025 | Post-installed Anchors | — | special |
| 07/21/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 07/21/2025 | Post-installed Anchors | — | special |
| 07/21/2025 | Final | — | progress |
| 07/21/2025 | Energy Code Compliance Inspections | — | progress |
| 07/21/2025 | HVAC-R and service water heating equipment | — | energy_progress |
| 07/21/2025 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 07/21/2025 | Maintenance information | — | energy_progress |
| 07/21/2025 | HVAC-R and service water heating system controls | — | energy_progress |
| 07/21/2025 | Sprinkler Systems | — | special |