← Back
City residence, one family
1 PATCHIN PLACE
MANHATTAN · BIN 1010559
💬 Discuss this project
1848Year Built
3Stories
A4Building Class
C1-6Zoning
2,520 sfGross Floor Area
1Units
Rent Stabilized0 Open Violations
City residence, one family · Owner of record: OR PATCHIN PLACE, LLC · 1,260 sf lot · 2 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof1p · 1 filing · 4 docs
Floor 349p · 1 filing · 20 docs
Floor 248p · 1 filing · 20 docs
Floor 148p · 1 filing · 20 docs
Basement48p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OR PATCHIN PLACE LLC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DKA CONSULTING P.C.908/20/2024
READ ARCHITECTURE DESIGN DPC305/10/2024
KWHC CONSULTING ENGINEER PLLC101/03/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J CALLAHAN CONSULTING603/21/2026
HWL ENGINEERING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HONEST & QUALITY CORPGeneral Contractor707/08/2026
I DO PLUMBING & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DKA CONSULTING PC3150308/20/2024
STUDIO NYANDAK ARCHITECTU8378101/03/2023
Building Lifecycle
All (78)Filed (13)Permit Issued (7)Signed Off (1)Violation (10)Inspection (5)Objection (12)Special Inspection (30)
08/05/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/21/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/05/2025
Signed off — Alteration
M00735605-I1
10/17/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/21/2024
Special inspection requirement — HVAC-R and service water heating system controls
Damon Amadio
08/21/2024
Special inspection requirement — Ventilation and air distribution system
Damon Amadio
08/21/2024
Special inspection requirement — HVAC-R and service water heating equipment
Damon Amadio
08/21/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Damon Amadio
08/21/2024
Special inspection requirement — Energy Code Compliance Inspections
Damon Amadio
08/21/2024
Special inspection requirement — Final
Damon Amadio
08/21/2024
Special inspection requirement — Mechanical Systems
Damon Amadio
08/20/2024
Filed — Alteration CO
INSTALLATION OF NEW HVAC SYSTEM
M00741368-P4
07/15/2024
Filed — Alteration CO
INSTALLATION OF NEW HVAC SYSTEM
M00741368-P8
05/28/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/28/2024
Special inspection requirement — Fire-Resistance Rated Construction
Come Menage
05/28/2024
Special inspection requirement — Air barrier - visual inspection
Come Menage
05/28/2024
Special inspection requirement — Interior lighting power
Come Menage
05/28/2024
Special inspection requirement — Fenestration areas
Come Menage
05/28/2024
Special inspection requirement — Exterior lighting power
Come Menage
05/28/2024
Special inspection requirement — Lighting controls
Come Menage
05/21/2024
Filed — Alteration CO
INSTALLATION OF NEW HVAC SYSTEM
M00741368-P7
05/16/2024
Objection raised — Scope
05/16/2024
Objection resolved — Addressed
05/13/2024
Filed — Alteration CO
INSTALLATION OF NEW HVAC SYSTEM
M00741368-P6
05/10/2024
Filed — Alteration CO
INSTALLATION OF NEW HVAC SYSTEM
M00741368-P2
05/01/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/24/2024
Special inspection requirement — Fire-Resistance Rated Construction
04/24/2024
Special inspection requirement — Exterior lighting power
04/24/2024
Special inspection requirement — Fenestration areas
04/24/2024
Special inspection requirement — Interior lighting power
04/24/2024
Special inspection requirement — Air barrier - visual inspection
04/24/2024
Special inspection requirement — Lighting controls
04/19/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/12/2024
Filed — Alteration CO
INSTALLATION OF NEW HVAC SYSTEM
M00741368-P5
04/03/2024
Filed — Alteration CO
INSTALLATION OF NEW HVAC SYSTEM
M00741368-P3
03/18/2024
Permit issued — Mechanical Systems
M00741368-S2-MS
03/01/2024
Permit issued — Plumbing
M00741368-S3-PL
01/29/2024
Permit issued — General Construction
M00741368-I1-GC
01/25/2023
Permit issued — Structural
M00741368-S1-ST
01/19/2023
Permit issued — Structural
M00741368-S1-ST
01/10/2023
Filed — Alteration CO
INSTALLATION OF NEW HVAC SYSTEM
M00741368-P1
01/10/2023
Special inspection requirement — Mechanical Systems
Damon Amadio
01/10/2023
Special inspection requirement — Ventilation and air distribution system
Damon Amadio
01/10/2023
Special inspection requirement — HVAC-R and service water heating equipment
Damon Amadio
01/10/2023
Special inspection requirement — HVAC-R and service water heating system controls
Damon Amadio
01/10/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Damon Amadio
01/10/2023
Special inspection requirement — Final
Damon Amadio
01/10/2023
Special inspection requirement — Energy Code Compliance Inspections
Damon Amadio
01/05/2023
Filed — Alteration CO
INSTALLATION OF NEW HVAC SYSTEM
M00741368-S2
01/05/2023
Filed — Alteration CO
INSTALLATION OF NEW HVAC SYSTEM
M00741368-S3
01/05/2023
Permit issued — General Construction
M00741368-I1-GC
01/03/2023
Filed — Alteration CO
INSTALLATION OF NEW HVAC SYSTEM
M00741368-S1
11/12/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
TENZIN NYANDAK
11/12/2022
Special inspection requirement — Structural Steel - Welding
TENZIN NYANDAK
10/04/2022
Objection resolved — Addressed
10/04/2022
Objection resolved — Addressed
09/14/2022
Objection resolved — Addressed
09/14/2022
Objection resolved — Addressed
09/14/2022
Objection resolved — Addressed
Latest 60 of 78 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedHONEST QUALITY03/18/2024
DOB NOWPlumbingPermit IssuedI DO PLUMBING & HTG INC03/01/2024
DOB NOWGeneral ConstructionPermit IssuedHONEST QUALITY01/29/2024
DOB NOWStructuralSigned-offHONEST QUALITY01/25/2023
DOB NOWStructuralSigned-offHONEST QUALITY01/19/2023
DOB NOWGeneral ConstructionPermit IssuedHONEST QUALITY01/05/2023
DOB NOWGeneral ConstructionSigned-offHONEST QUALITY07/28/2022
1 project · most recent 08/20/2024
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/20/2024Permit IssuedHONEST & QUALITY CORPHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Lg ×24
Ventilation
Greenheck SP-B110 100 CFM · Exhaust Fan ×3
SQ-60 100 CFM · Exhaust Fan ×3
1 project · most recent 08/20/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/20/2024Permit IssuedI DO PLUMBING & HTG INCGas, Storm, Water/Sanitary
4 projects · most recent 03/06/2024
General Wiring
FiledStatusContractorScope
03/06/2024CompleteASKO ELEC CONST & MAIN INGeneral Wiring
08/08/2022CompleteASKO ELEC CONST & MAIN INGeneral Wiring
04/27/2021Permit IssuedMACINTOSH ELECTRIC CORP1 meters
01/18/2021CompleteMACINTOSH ELECTRIC CORPGeneral Wiring
1 project · most recent 08/20/2024
Steel Concrete Wood
FiledStatusContractorScope
08/20/2024Permit IssuedHONEST & QUALITY CORPSteel, Concrete, Wood
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/05/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/21/2026Pass-Final CND-Occupancy InspectionPassView ↗
10/17/2024Pass-Final CND-Occupancy InspectionPassView ↗
05/01/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/19/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 35
DateRequirementInspectorRole
08/21/2024HVAC-R and service water heating system controlsDamon Amadioenergy_progress
08/21/2024Ventilation and air distribution systemDamon Amadioenergy_progress
08/21/2024HVAC-R and service water heating equipmentDamon Amadioenergy_progress
08/21/2024HVAC-R and service water piping design and insulationDamon Amadioenergy_progress
08/21/2024Energy Code Compliance InspectionsDamon Amadioprogress
08/21/2024FinalDamon Amadioprogress
08/21/2024Mechanical SystemsDamon Amadiospecial
05/28/2024Fire-Resistant Penetrations and Joints—special
05/28/2024Fire-Resistance Rated ConstructionCome Menageprogress
05/28/2024Air barrier - visual inspectionCome Menageenergy_progress
05/28/2024Interior lighting powerCome Menageenergy_progress
05/28/2024Fenestration areasCome Menageenergy_progress
05/28/2024Exterior lighting powerCome Menageenergy_progress
05/28/2024Lighting controlsCome Menageenergy_progress
04/24/2024Fire-Resistant Penetrations and Joints—special
04/24/2024Fire-Resistance Rated Construction—progress
04/24/2024Exterior lighting power—energy_progress
04/24/2024Fenestration areas—energy_progress
04/24/2024Interior lighting power—energy_progress
04/24/2024Air barrier - visual inspection—energy_progress
04/24/2024Lighting controls—energy_progress
01/10/2023Mechanical SystemsDamon Amadiospecial
01/10/2023Ventilation and air distribution systemDamon Amadioenergy_progress
01/10/2023HVAC-R and service water heating equipmentDamon Amadioenergy_progress
01/10/2023HVAC-R and service water heating system controlsDamon Amadioenergy_progress
Latest 25 of 35.
▾Documents — 64 on file (BIS + DOB NOW)
▸Plans & Drawings13
▸DOB NOWPlans/Sketch13
09/02/2026M00735605-I1Request digital key ↗
08/27/2026M00741368-P7Request digital key ↗
08/27/2026M00741368-P3Request digital key ↗
Showing 3 of 13 on file for this type
▸Applications & Permits13
▸DOB NOWLPC Approval/Permit13
08/13/2026M00741368-P3Open ↗
08/13/2026M00741368-P1Open ↗
08/13/2026M00735605-I1Open ↗
Showing 3 of 13 on file for this type
▸Seals & Professional Certifications20
▸DOB NOWDPL-1: Design Professional Seal & Signature13
09/02/2026M00735605-I1Open ↗
08/13/2026M00741368-P1Open ↗
08/13/2026M00741368-P4Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/30/2026M00741368-S1Open ↗
08/24/2026M00741368-S2Open ↗
08/24/2026M00741368-S2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026M00741368-S1Open ↗
08/24/2026M00741368-S2Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/13/2026M00741368-I1Open ↗
08/13/2026M00741368-P2Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026M00741368-I1Open ↗
▸Environmental & Asbestos13
▸DOB NOWDEP ACP-5: Asbestos Assessment Report13
09/02/2026M00735605-I1Open ↗
08/13/2026M00741368-P2Open ↗
08/13/2026M00741368-P4Open ↗
Showing 3 of 13 on file for this type
▸Other Documents2
▸DOB NOWProperty Ownership Certification2
08/13/2026M00741368-P2Open ↗
08/13/2026M00741368-I1Open ↗