← Back
Parks / recreation facility
1 WARDS ISLAND
MANHATTAN · BIN 1088234
💬 Discuss this project
0Year Built
1Stories
Q1Building Class
PARKZoning
948 sfGross Floor Area
1Units
202 Open Violations 2 unresolved · 200 paperwork only ▸
Parks / recreation facility · Owner of record: NYC DEPARTMENT OF PARKS AND RECREATION · 12,300,030 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction30p · 1 filing · 20 docs
Floor 1Under Construction79p · 1 filing · 20 docs
CellarUnder Construction9p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC PARKS DEPARTMENT2609/13/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WILLIAM VITACCO ASSOCIATES1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
THE WHITING-TURNER CONTRAGeneral Contractor907/02/2026
PRIME MECHANICAL CONTRACTGeneral Contractor307/08/2026
ASPRO PLUMBING INCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DELTA TESTING LABS6871008/20/2026
Building Lifecycle
All (82)Filed (13)Permit Issued (12)Inspection (5)Objection (22)Special Inspection (30)
08/20/2026
Filed — Alteration CO
Foundation work associated with alteration of existing nature center.
M01225674-P5
08/20/2026
Filed — Alteration CO
Foundation work associated with alteration of existing nature center.
M01225674-P4
08/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
RICHARD GREENWALD
08/05/2026
Special inspection requirement — Air barrier - visual inspection
RICHARD GREENWALD
08/05/2026
Special inspection requirement — Insulation placement and R values
RICHARD GREENWALD
08/05/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
RICHARD GREENWALD
08/05/2026
Special inspection requirement — Fenestration areas
RICHARD GREENWALD
08/05/2026
Special inspection requirement — Fenestration air leakage
RICHARD GREENWALD
08/05/2026
Special inspection requirement — Fire-Resistance Rated Construction
RICHARD GREENWALD
07/27/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/27/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/24/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/11/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/11/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/03/2026
Special inspection requirement — Subgrade Inspections
RICHARD GREENWALD
06/03/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
RICHARD GREENWALD
06/03/2026
Special inspection requirement — Final
RICHARD GREENWALD
06/03/2026
Special inspection requirement — Footing and Foundation
RICHARD GREENWALD
06/03/2026
Special inspection requirement — Final
RICHARD GREENWALD
06/03/2026
Special inspection requirement — Structural Steel - High Strength Bolting
RICHARD GREENWALD
06/03/2026
Special inspection requirement — Structural Steel - Welding
RICHARD GREENWALD
06/03/2026
Special inspection requirement — Masonry
06/03/2026
Special inspection requirement — Structural Steel - Details
RICHARD GREENWALD
06/03/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
RICHARD GREENWALD
06/03/2026
Special inspection requirement — Concrete - Cast-In-Place
RICHARD GREENWALD
06/03/2026
Special inspection requirement — Wood – Prefabricated I-Joists
RICHARD GREENWALD
06/01/2026
Filed — Alteration CO
Foundation work associated with alteration of existing nature center.
M01225674-P3
06/01/2026
Filed — Alteration CO
Foundation work associated with alteration of existing nature center.
M01225674-P2
05/27/2026
Special inspection requirement — Masonry
05/14/2026
Special inspection requirement — Structural Steel - High Strength Bolting
RICHARD GREENWALD
05/14/2026
Special inspection requirement — Structural Steel - Welding
RICHARD GREENWALD
05/14/2026
Special inspection requirement — Wood – Prefabricated I-Joists
RICHARD GREENWALD
05/14/2026
Special inspection requirement — Final
RICHARD GREENWALD
05/14/2026
Special inspection requirement — Structural Steel - Details
RICHARD GREENWALD
04/17/2026
Permit issued — Plumbing
M01225674-S2-PL
04/14/2026
Permit issued — Mechanical Systems
M01225674-S1-MS
04/14/2026
Permit issued — General Construction
M01225674-I1-GC
04/10/2026
Permit issued — Mechanical Systems
M01225674-S1-MS
03/27/2026
Objection resolved — Addressed
03/24/2026
Permit issued — Structural
M01225674-S7-ST
03/17/2026
Special inspection requirement — Maintenance information
RICHARD GREENWALD
03/11/2026
Permit issued — Mechanical Systems
M01225674-S1-MS
03/06/2026
Special inspection requirement — HVAC-R and service water heating equipment
RICHARD GREENWALD
03/06/2026
Special inspection requirement — HVAC-R and service water heating system controls
RICHARD GREENWALD
02/18/2026
Objection raised — Energy
02/10/2026
Permit issued — General Construction
M01225674-I1-GC
02/06/2026
Permit issued — Structural
M01225674-S7-ST
01/22/2026
Objection resolved — Addressed
01/22/2026
Objection resolved — Addressed
01/06/2026
Filed — Alteration CO
Foundation work associated with alteration of existing nature center.
M01225674-P1
01/06/2026
Objection resolved — Addressed
12/29/2025
Objection resolved — Addressed
12/27/2025
Objection raised — Structural
12/24/2025
Objection resolved — Addressed
12/24/2025
Objection resolved — Addressed
12/24/2025
Objection resolved — Addressed
12/18/2025
Filed — Alteration CO
Foundation work associated with alteration of existing nature center.
M01225674-S7
12/18/2025
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
RICHARD GREENWALD
12/18/2025
Special inspection requirement — Footing and Foundation
RICHARD GREENWALD
12/09/2025
Permit issued — Structural
M01225674-S6-ST
Latest 60 of 82 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedASPRO PLUMBING INC04/17/2026
DOB NOWMechanical SystemsPermit IssuedPRIME MECHANICAL CONTRACT04/14/2026
DOB NOWGeneral ConstructionPermit IssuedTHE WHITING-TURNER CONTRA04/14/2026
DOB NOWMechanical SystemsPermit IssuedPRIME MECHANICAL CONTRACT04/10/2026
DOB NOWStructuralPermit IssuedTHE WHITING-TURNER CONTRA03/24/2026
DOB NOWMechanical SystemsPermit IssuedPRIME MECHANICAL CONTRACT03/11/2026
DOB NOWGeneral ConstructionPermit IssuedTHE WHITING-TURNER CONTRA02/10/2026
DOB NOWStructuralPermit IssuedTHE WHITING-TURNER CONTRA02/06/2026
DOB NOWStructuralPermit IssuedTHE WHITING-TURNER CONTRA12/09/2025
DOB NOWEarth WorkPermit IssuedTHE WHITING-TURNER CONTRA11/14/2025
DOB NOWFoundationPermit IssuedTHE WHITING-TURNER CONTRA10/14/2025
DOB NOWStructuralPermit IssuedTHE WHITING-TURNER CONTRA10/14/2025
1 project · most recent 08/20/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/20/2026Permit IssuedTHE WHITING-TURNER CONTRAHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Lg ARUN072BSS5 69,000 BTU · Vrf Outdoor ×2
ARNU123L2G4 12,300 BTU · Vrf Indoor ×1
ARNU123MAA4 12,300 BTU · Vrf Indoor ×1
ARNU243TAA4 24,200 BTU · Vrf Indoor ×1
ARNU483M3A4 48,100 BTU · Vrf Indoor ×1
ARNU543B8A4 54,000 BTU · Vrf Indoor ×1
Ventilation
Greenheck BSQ-90 780 CFM · Exhaust Fan ×2
1 project · most recent 08/20/2026
Storm Water/Sanitary
FiledStatusContractorScope
08/20/2026Permit IssuedASPRO PLUMBING, INCStorm, Water/Sanitary
1 project · most recent 10/02/2025
General Wiring
FiledStatusContractorScope
10/02/2025Permit IssuedSKF ELECTRICAL CORPGeneral Wiring
1 project · most recent 08/20/2026
Steel Masonry
FiledStatusContractorScope
08/20/2026Permit IssuedASPRO PLUMBING, INCSteel, Masonry
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/27/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/27/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/24/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/11/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/11/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 56
DateRequirementInspectorRole
08/05/2026Fire-Resistant Penetrations and JointsRICHARD GREENWALDspecial
08/05/2026Air barrier - visual inspectionRICHARD GREENWALDenergy_progress
08/05/2026Insulation placement and R valuesRICHARD GREENWALDenergy_progress
08/05/2026Fenestration and door U-factor and product ratingsRICHARD GREENWALDenergy_progress
08/05/2026Fenestration areasRICHARD GREENWALDenergy_progress
08/05/2026Fenestration air leakageRICHARD GREENWALDenergy_progress
08/05/2026Fire-Resistance Rated ConstructionRICHARD GREENWALDprogress
06/03/2026Subgrade InspectionsRICHARD GREENWALDspecial
06/03/2026Structural Stability – Alterations of existing buildingsRICHARD GREENWALDspecial
06/03/2026FinalRICHARD GREENWALDprogress
06/03/2026Footing and FoundationRICHARD GREENWALDprogress
06/03/2026FinalRICHARD GREENWALDprogress
06/03/2026Structural Steel - High Strength BoltingRICHARD GREENWALDspecial
06/03/2026Structural Steel - WeldingRICHARD GREENWALDspecial
06/03/2026Masonry—special
06/03/2026Structural Steel - DetailsRICHARD GREENWALDspecial
06/03/2026Subsurface Conditions – Fill Placement & In-Place DensityRICHARD GREENWALDspecial
06/03/2026Concrete - Cast-In-PlaceRICHARD GREENWALDspecial
06/03/2026Wood – Prefabricated I-JoistsRICHARD GREENWALDspecial
05/27/2026Masonry—special
05/14/2026Structural Steel - High Strength BoltingRICHARD GREENWALDspecial
05/14/2026Structural Steel - WeldingRICHARD GREENWALDspecial
05/14/2026Wood – Prefabricated I-JoistsRICHARD GREENWALDspecial
05/14/2026FinalRICHARD GREENWALDprogress
05/14/2026Structural Steel - DetailsRICHARD GREENWALDspecial
Latest 25 of 56.
▾Documents — 118 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
08/21/2026M01225674-P5Request digital key ↗
08/21/2026M01225674-P4Request digital key ↗
08/17/2026M01225674-I1Request digital key ↗
Showing 3 of 15 on file for this type
▸Seals & Professional Certifications67
▸DOB NOWProgress Inspector Seal & Signature32
09/23/2026M01225674-S1Open ↗
09/23/2026M01225674-S1Open ↗
09/23/2026M01225674-S1Open ↗
Showing 3 of 32 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature22
09/23/2026M01225674-S1Open ↗
09/01/2026M01225674-S4Open ↗
09/01/2026M01225674-S4Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature13
08/17/2026M01225674-P2Open ↗
08/17/2026M01225674-P5Open ↗
08/17/2026M01225674-P3Open ↗
Showing 3 of 13 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/17/2026M01225674-P4Open ↗
08/13/2026M01225674-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form8
08/13/2026M01225674-S5Open ↗
08/13/2026M01225674-S3Open ↗
08/13/2026M01225674-S4Open ↗
Showing 3 of 8 on file for this type
▸Approvals, Objections & Sign-offs26
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter13
08/17/2026M01225674-P4Open ↗
08/17/2026M01225674-P3Open ↗
08/17/2026M01225674-P5Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)13
08/17/2026M01225674-P4Open ↗
08/17/2026M01225674-P2Open ↗
08/17/2026M01225674-P3Open ↗
Showing 3 of 13 on file for this type