← Back
Two family brick
10-11 ROSE STREET
QUEENS · Far Rockaway-Bayswater · BIN 4298211
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R4AZoning
3,016 sfGross Floor Area
2Units
Two family brick · 4,741 sf lot · 0.64 FAR built · Flood zone X
Locations of Work
Electrical
Roof2p · 1 filing · 13 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR204/21/2025
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281204/21/2025
Building Lifecycle
All (14)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (10)
09/29/2025
Signed off — Alteration
Q01143936-I1
04/21/2025
Filed — Alteration
Q01143936-P1
04/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
04/21/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
04/21/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
04/21/2025
Special inspection requirement — Final
Mina Makar
04/21/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
04/21/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
04/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
04/21/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
04/21/2025
Special inspection requirement — Final
Mina Makar
04/21/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
11/22/2024
Permit issued — Solar
Q01143936-I1-SL
11/19/2024
Filed — Alteration
Q01143936-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offMOMENTUM SOLAR11/22/2024
1 project · most recent 11/18/2024
FiledStatusContractorScope
11/18/2024CompleteISLAND ELECTRIC CORP—
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
04/21/2025Fire-Resistant Penetrations and JointsMina Makarspecial
04/21/2025Structural Stability – Alterations of existing buildingsMina Makarspecial
04/21/2025Energy Code Compliance InspectionsMina Makarprogress
04/21/2025FinalMina Makarprogress
04/21/2025Air barrier - visual inspectionMina Makarenergy_progress
04/21/2025Structural Stability – Alterations of existing buildingsMina Makarspecial
04/21/2025Fire-Resistant Penetrations and JointsMina Makarspecial
04/21/2025Energy Code Compliance InspectionsMina Makarprogress
04/21/2025FinalMina Makarprogress
04/21/2025Air barrier - visual inspectionMina Makarenergy_progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01143936-P1Request digital key ↗
08/21/2026Q01143936-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
09/02/2026Q01143936-I1Open ↗
09/02/2026Q01143936-I1Open ↗
08/24/2026Q01143936-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026Q01143936-I1Open ↗
08/13/2026Q01143936-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/02/2026Q01143936-I1Open ↗
08/24/2026Q01143936-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026Q01143936-I1Open ↗
08/13/2026Q01143936-P1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01143936-I1Open ↗