← Back
Two stories - detached, small or mid-size
10 FLORIDA AVENUE
STATEN ISLAND · BIN 5045576
💬 Discuss this project
1920Year Built
1.5Stories
A1Building Class
R3-1Zoning
1,274 sfGross Floor Area
1Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 2,345 sf lot · 0.54 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar1p · 1 filing · 12 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STEVEN R. SAVINO ARCHITECT PC412/05/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
COBOT PLUMBING AND HEATING INCPlumbing207/08/2026
KING KONG G/C INCGeneral Contractor107/08/2026
Building Lifecycle
All (32)Filed (4)Permit Issued (3)Signed Off (3)Violation (10)Inspection (3)Special Inspection (9)
03/12/2026
Signed off — Alteration
CAP AND REMOVE GAS FIXTURES IN THE ATTIC, BASEMENT AND CELLAR WITH ASSOCIATED PIPING AND INSTALL AN ELECTRIC WATER HEATER IN THE CELLAR SPACE.
S01263197-I1
01/22/2026
Signed off — Alteration
CAP AND REMOVE GAS FIXTURES IN THE ATTIC, BASEMENT AND CELLAR WITH ASSOCIATED PIPING AND INSTALL AN ELECTRIC WATER HEATER IN THE CELLAR SPACE.
S01263197-S1
12/08/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/08/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/08/2025
Special inspection requirement — HVAC-R and service water heating system controls
Steven Savino
12/08/2025
Special inspection requirement — Energy Code Compliance Inspections
Steven Savino
12/08/2025
Special inspection requirement — HVAC-R and service water heating equipment
Steven Savino
12/08/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Steven Savino
12/05/2025
Filed — Alteration
CAP AND REMOVE GAS FIXTURES IN THE ATTIC, BASEMENT AND CELLAR WITH ASSOCIATED PIPING AND INSTALL AN ELECTRIC WATER HEATER IN THE CELLAR SPACE.
S01263197-P1
12/02/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Steven Savino
12/02/2025
Special inspection requirement — Energy Code Compliance Inspections
Steven Savino
12/02/2025
Special inspection requirement — HVAC-R and service water heating equipment
Steven Savino
12/02/2025
Special inspection requirement — HVAC-R and service water heating system controls
Steven Savino
11/24/2025
Permit issued — Plumbing
S01263197-S1-PL
10/17/2025
Filed — Alteration
CAP AND REMOVE GAS FIXTURES IN THE ATTIC, BASEMENT AND CELLAR WITH ASSOCIATED PIPING AND INSTALL AN ELECTRIC WATER HEATER IN THE CELLAR SPACE.
S01263197-S1
09/24/2025
Signed off — Alteration
S01267731-I1
09/15/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/27/2025
Permit issued — Plumbing
S01263197-I1-PL
08/25/2025
Permit issued — General Construction
S01267731-I1-GC
08/18/2025
Filed — Alteration
CAP AND REMOVE GAS FIXTURES IN THE ATTIC, BASEMENT AND CELLAR WITH ASSOCIATED PIPING AND INSTALL AN ELECTRIC WATER HEATER IN THE CELLAR SPACE.
S01263197-I1
08/18/2025
Filed — Alteration
S01267731-I1
08/06/2025
Special inspection requirement — Final
Steven Savino
03/29/2023
Violation issued (HPD, closed)
A
03/08/2022
Violation issued (HPD, closed)
A
04/16/2021
Violation issued (HPD, closed)
A
11/23/2016
Violation issued (HPD, closed)
I
04/20/2016
Violation issued (HPD, closed)
B
10/16/2015
Violation issued (HPD, closed)
I
03/02/2015
Violation issued (HPD, closed)
I
04/20/1998
Violation issued (ECB, closed)
Construction
04/20/1998
Violation issued (ECB, closed)
Construction
04/20/1998
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCOBOT PLUMBING AND HEATIN11/24/2025
DOB NOWPlumbingSigned-offCOBOT PLUMBING AND HEATIN08/27/2025
DOB NOWGeneral ConstructionSigned-offKING KONG G/C INC08/25/2025
BISPLISSUEDCOBOT PLUMBING AND HEATING INC07/10/2025
BISPLISSUEDCARMINE'S MECHANICAL INC01/08/2004
BISOTISSUEDN/A10/28/1998
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
12/08/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/08/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/15/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
12/08/2025HVAC-R and service water heating system controlsSteven Savinoenergy_progress
12/08/2025Energy Code Compliance InspectionsSteven Savinoprogress
12/08/2025HVAC-R and service water heating equipmentSteven Savinoenergy_progress
12/08/2025HVAC-R and service water piping design and insulationSteven Savinoenergy_progress
12/02/2025HVAC-R and service water piping design and insulationSteven Savinoenergy_progress
12/02/2025Energy Code Compliance InspectionsSteven Savinoprogress
12/02/2025HVAC-R and service water heating equipmentSteven Savinoenergy_progress
12/02/2025HVAC-R and service water heating system controlsSteven Savinoenergy_progress
08/06/2025FinalSteven Savinoprogress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/18/2026S01263197-I1Request digital key ↗
08/18/2026S01263197-S1Request digital key ↗
08/18/2026S01263197-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION3
11/03/2025500281884Open ↗
10/03/2025500281884Open ↗
06/13/2025500660858Open ↗
▸BISWORK PERMIT APPLICATION1
07/11/2025500660858Open ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature7
08/28/2026S01267731-I1Open ↗
08/27/2026S01263197-P1Open ↗
08/27/2026S01263197-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/18/2026S01263197-S1Open ↗
08/13/2026S01267731-I1Open ↗
08/13/2026S01263197-P1Open ↗
Showing 3 of 4 on file for this type
▸Trade Schedules & Equipment1
▸BISPLUMBING (PL) SIGNOFF1
07/28/2025500660858Open ↗
▸Inspections & Test Reports1
▸BIS* FINAL INSPECTION DIRECTIVE 14 OF 19751
07/28/2025500660858Open ↗
▸Approvals, Objections & Sign-offs2
▸BISSUPERSEDING LETTER1
07/11/2025500660858Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
07/29/2025500660858Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT (FINAL): PW31
07/28/2025500660858Open ↗
▸Filing & Intake Forms1
▸BISBOROUGH INTAKE FORM1
07/11/2025500660858Open ↗
▸Other Documents1
▸BIS* FIRE STOPS 27-3451
07/28/2025500660858Open ↗