← Back
City residence, one family
10 PINEAPPLE STREET
BROOKLYN · BIN 3001712
💬 Discuss this project
1829Year Built
3Stories
A4Building Class
R6Zoning
3,924 sfGross Floor Area
1Units
0 Open Violations
City residence, one family · 1,557 sf lot · 2.52 FAR built · Flood zone X
Locations of Work
Mechanical
Roof1p · 1 filing · 7 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/21/2025$7.0M—ROBERT J. CRESCI GST TRUST → Private party$1,774/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PAUL DENIS ASSOCIATES103/04/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
D D EXPEDITORS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CENTRAL AIR CONDITIONINGGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PAUL DENIS ASSOCIATES2472103/04/2026
Building Lifecycle
All (7)Filed (1)Permit Issued (1)Signed Off (1)Violation (2)Special Inspection (2)
04/22/2026
Signed off — Alteration
Install (2) roof top condensers on existing supports and (11) air handlers.
B01302674-I1
03/05/2026
Permit issued — Mechanical Systems
B01302674-I1-GC-CX
03/04/2026
Filed — Alteration
Install (2) roof top condensers on existing supports and (11) air handlers.
B01302674-I1
10/14/2025
Special inspection requirement — Mechanical Systems
PAUL DENIS
10/14/2025
Special inspection requirement — Final
PAUL DENIS
12/18/1985
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/18/1985
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offCENTRAL AIR CONDITIONING03/05/2026
BISOTISSUEDTHE LORANCO CORP06/30/1997
BISEQISSUEDTHE LORANCO CORP06/30/1997
1 project · most recent 03/04/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/04/2026Signed-offCENTRAL AIR CONDITIONINGHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric (11) indoor air handler units. (4) PFFY-P08NRMUE, (1) PFFY-P12NRMU-E1, (2) PFFY-P15NRMU-E, (2) PFFY-P18NRMU-E1, (1) PVFY-P08NAMU-E1, (1)PEFY-P18NMAU-E5 136,000 CFM · Vrf Indoor ×11
MXZ-SM60NAM2-U1 132,000 BTU · Condensing Unit ×2
2 projects · most recent 05/06/2026
General Wiring
FiledStatusContractorScope
05/06/2026CompleteW 8 ELECTRIC CORPGeneral Wiring
01/23/2025CompleteSUPER CHARGED ELEC. INC.General Wiring
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
10/14/2025Mechanical SystemsPAUL DENISspecial
10/14/2025FinalPAUL DENISprogress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026B01302674-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
08/20/2024300626785Open ↗
08/14/2024300626785Open ↗
▸DOB NOWLPC Approval/Permit1
08/13/2026B01302674-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B01302674-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/02/2026B01302674-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/02/2026B01302674-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B01302674-I1Open ↗
▸Inspections & Test Reports2
▸BIS* FINAL INSPECTION DIRECTIVE 14 OF 19751
08/20/2024300626785Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
08/20/2024300626785Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
09/04/2024300626785Open ↗
▸BISLANDMARKS SIGNOFF1
08/30/2024300626785Open ↗
▸Filing & Intake Forms1
▸BISADDITIONAL INFORMATION1
08/20/2024300626785Open ↗
▸Other Documents1
▸DOB NOWProof of Historic Building1
08/13/2026B01302674-I1Open ↗