| Owner | Filings | Most Recent |
|---|---|---|
| HAPPIER | 5 | 04/09/2026 |
| T-MOBILE | 3 | 03/22/2026 |
| 82C LLC | 1 | 03/22/2026 |
| WHITE-BOERUM REALTY CP | 6 | 03/22/2026 |
| 304 BOERUM STREET | 26 | 03/22/2026 |
| 304 BOERUM STREET LLC WHI | 4 | 03/22/2026 |
| OWNER OF PREMISES | 1 | 03/22/2026 |
| HARRY J.RASHTI & CO. | 1 | 03/22/2026 |
| CONTROLLED | 1 | 03/21/2026 |
| 49 BOGART STREET | 3 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 12/27/2021 | $10.0M | — | 304 BOERUM STREET LLC → 82C LLC | $243/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| PAKNIA ENGINEERING, PC | 3 | 03/21/2023 |
| A SAXON DESIGN GROUP | 1 | 12/28/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| PAKNIA ENGINEERING & ARCHITECTURE, | 6 | 03/21/2026 |
| CCM CONSULTING GROUP, INC. | 1 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| GOTHAM COMMUNICATIONS LLC | General Contractor | 3 | 03/21/2026 |
| ERROL GLANVILLE | Electrical | 1 | 03/21/2026 |
| FOY, REMER | Electrical | 1 | 03/21/2026 |
| GARCIA, ROBERT | Electrical | 1 | 03/21/2026 |
| H&F IRON WORKS | Electrical | 1 | 03/21/2026 |
| CARL WEISS | Electrical | 1 | 03/21/2026 |
| PISULA, KONRAD | Electrical | 1 | 03/21/2026 |
| YOUNG, CHRISTOPHER | Electrical | 1 | 03/21/2026 |
| C&M DRYWALL & ACOUSTIC CO | General Contractor | 1 | 04/09/2026 |
| MELVYN ZWEBNER | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| SHAHRISH SHUVO ENGINEERIN | 8524 | 3 | 03/21/2023 |
| R MARSAC CONSULTING LLC | 329 | 1 | 12/28/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Permit Issued | C&M DRYWALL & ACOUSTIC CO | 11/12/2025 |
| DOB NOW | Antenna | Signed-off | GOTHAM COMMUNICATIONS LLC | 04/15/2024 |
| BIS | FP | ISSUED | FIRE ZONE VENT & SUPP INC | 11/18/2015 |
| BIS | PL | ISSUED | PREMIER SEWER & WATERMAIN LLC, | 06/24/2015 |
| BIS | MH | ISSUED | ROB HERSCHENFELD DESIGN I | 06/15/2015 |
| BIS | OT | ISSUED | TELCOM ENGINEERING GP INC | 12/31/2013 |
| BIS | MH | ISSUED | DAVRIAL ENTERPRISES INC | 06/12/2001 |
| BIS | BL | ISSUED | UNFLAT & ASSOCIATES | 11/24/2000 |
| BIS | PL | ISSUED | UNFLAT ,ASSOCIATES | 11/16/2000 |
| BIS | OT | ISSUED | KAI GROUP INC | 06/20/2000 |
| BIS | PL | ISSUED | NAT'L MECH. SVCS PLBG LLC | 07/09/1998 |
| BIS | BL | ISSUED | NAT'L MECH. SVCS PLBG LLC | 07/09/1998 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 03/21/2023 | Permit Issued | C&M DRYWALL & ACOUSTIC CO | Air Conditioning Systems, Heating and Air Conditioning Systems, Ventilation Systems | Cooling York HCBA-F060SA 56,000 BTU · Condensing Unit ×4 H1RA048S06D 47,000 BTU · Condensing Unit ×2 HABA-F042SE 41,000 BTU · Condensing Unit ×2 H1RA042S06D 41,000 BTU · Condensing Unit ×1 HABA-F048SE 47,000 BTU · Condensing Unit ×1 TCGD42S41S1A 42,000 BTU · Condensing Unit ×1 YCJD42S41S1A 42,000 BTU · Condensing Unit ×1 International Comfort Products CAC060AKC4 56,500 BTU · Condensing Unit ×1 NAC048AKC3 46,000 BTU · Condensing Unit ×1 Carrier 24ACR360A310 60,000 BTU · Condensing Unit ×1 Comfort Aire RSG1336S1M 36,000 BTU · Condensing Unit ×1 Lennox 13ACX-060-230-02 60,000 BTU · Condensing Unit ×1 Heat / Cool Lg LMU300HHV 34,320 BTU · Vrf Outdoor ×1 Ventilation Renewaire HE10INH 1,100 CFM · Erv ×3 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/09/2023 | — | — | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/09/2023 | — | — | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/21/2023 | Permit Issued | C&M DRYWALL & ACOUSTIC CO | Sidewalk Shed |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/05/2024 | HVAC-R and service water heating system controls | Shahrish Shuvo | energy_progress |
| 08/05/2024 | HVAC-R and service water heating equipment | Shahrish Shuvo | energy_progress |
| 08/05/2024 | HVAC-R and service water piping design and insulation | Shahrish Shuvo | energy_progress |
| 02/02/2023 | Fire-Resistance Rated Construction | Shahrish Shuvo | progress |
| 02/02/2023 | Shutoff dampers | Shahrish Shuvo | energy_progress |
| 02/02/2023 | Tenant Protection Plan Compliance | Shahrish Shuvo | special |
| 02/02/2023 | Energy Code Compliance Inspections | Shahrish Shuvo | progress |
| 02/02/2023 | Permanent certificate | Shahrish Shuvo | energy_progress |
| 02/02/2023 | Fire-Resistant Penetrations and Joints | Shahrish Shuvo | special |
| 02/02/2023 | Fenestration areas | Shahrish Shuvo | energy_progress |
| 02/02/2023 | Fenestration air leakage | Shahrish Shuvo | energy_progress |
| 02/02/2023 | Duct leakage testing, insulation and design | Shahrish Shuvo | energy_progress |
| 02/02/2023 | Maintenance information | Shahrish Shuvo | energy_progress |
| 02/02/2023 | Fenestration and door U-factor and product ratings | Shahrish Shuvo | energy_progress |
| 02/02/2023 | Ventilation and air distribution system | Shahrish Shuvo | energy_progress |
| 01/24/2023 | Final | Shahrish Shuvo | progress |
| 01/24/2023 | Mechanical Systems | Shahrish Shuvo | special |