← Back
Primarily 2 family with 1 store or office
1009 Fifth Avenue House
1009 5 AVENUE · BIN 1087074
💬 Discuss this project
1901Year Built
7Stories
S2Building Class
R10Zoning
19,575 sfGross Floor Area
3Units
Rent Stabilized30 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: METRO RE LLC · 2,717 sf lot · 7.2 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction44p · 2 filings · 20 docs
Floor 7Under Construction46p · 3 filings · 20 docs
Floor 6Under Construction56p · 5 filings · 20 docs
Floor 5Under Construction43p · 7 filings · 20 docs
Floor 4Under Construction44p · 7 filings · 20 docs
Floor 3Under Construction57p · 6 filings · 20 docs
Floor 2Under Construction57p · 7 filings · 20 docs
Floor 1Under Construction54p · 5 filings · 20 docs
CellarUnder Construction46p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SEBASTIAN CAPITAL8509/23/2026
METRO RE LLC603/22/2026
IRVINE REALTY CORP103/22/2026
IRVINE REALTY GROUP203/21/2026
1009 5TH AVE203/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BOYD CONSULTING2803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JAYLEX NYC CORPGeneral Contractor1308/26/2026
COW BAY SPRINKLER CORPGeneral Contractor1107/14/2026
FIVE BOROUGH NYC LLCFire Protection509/23/2026
DYNAIRE LLCGeneral Contractor403/21/2026
MACCARONE PLUMBING INCPlumbing106/27/2026
TOMASZ PUZAElectrical103/21/2026
XELA ELECTRICAL CORPElectrical103/22/2026
HIGH QUALITY ELECTRIC OFElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HANSEN ENGINEERING PC8174808/05/2026
BENDIX ENGINEERING, P.C.4293501/09/2026
CROSSCHECK INSPECTION SER544111/17/2025
MIDTOWN PRESERVATION ARCH2634110/14/2025
Building Lifecycle
All (192)Filed (31)Permit Issued (30)Violation (60)Inspection (5)Objection (36)Special Inspection (30)
09/22/2026
Permit issued — Sprinklers
M01254461-S5-EW-SP
09/22/2026
Permit issued — Standpipe
M01254461-S5-EW-SD
09/14/2026
Special inspection requirement — Standpipe Systems
Matthew Bendix
09/14/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Matthew Bendix
09/14/2026
Special inspection requirement — Sprinkler Systems
Matthew Bendix
09/14/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Matthew Bendix
08/25/2026
Permit issued — Protection and Mechanical Methods
M01447733-I1-PMM
08/24/2026
Filed — Alteration
INSTALLATION OF WORKING PLATFORM AS SHOWN ON DRAWINGS. NO CHANGE ON USE EGRESS OR OCCUPACNY. WE SHA;; COMPLY WITH CHPATER 33 OF 2022 B.C
M01447733-I1
08/24/2026
Filed — Alteration
INSTALLATION OF 1200LBS BETA HOIST ON SCAFFOLD AS SHOWN ON DRAWINGS. NO CHANGE IN USE EGRESS OR OCCUPANCY. WE SHALL COMPLY WITH CHPATER 33 OF 2022 B.C
M01130483-P1
08/14/2026
Special inspection requirement — Sprayed fire-resistant materials
08/14/2026
Special inspection requirement — Final
Dennis Mele
08/14/2026
Special inspection requirement — Fire-Resistance Rated Construction
08/14/2026
Special inspection requirement — Masonry
08/14/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
08/14/2026
Special inspection requirement — Air barrier - visual inspection
08/14/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/14/2026
Special inspection requirement — Energy Code Compliance Inspections
08/14/2026
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
08/14/2026
Special inspection requirement — Insulation placement and R values
08/14/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Ryan Hansen
08/13/2026
Objection resolved — Addressed
08/12/2026
Objection raised — Other
08/11/2026
Filed — Alteration
Filing for roof repair. No change to use, egress or occupancy.
M01221479-S4
08/10/2026
Objection raised — Other
08/05/2026
Filed — Alteration
Filing for roof repair. No change to use, egress or occupancy.
M01221479-P3
08/04/2026
Special inspection requirement — Fire-Resistance Rated Construction
08/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/04/2026
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
08/04/2026
Special inspection requirement — Masonry
08/04/2026
Special inspection requirement — Sprayed fire-resistant materials
08/04/2026
Special inspection requirement — Energy Code Compliance Inspections
08/04/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
08/04/2026
Special inspection requirement — Insulation placement and R values
08/04/2026
Special inspection requirement — Air barrier - visual inspection
08/03/2026
Filed — Alteration
PROTECTION PLATFORM DURING DEMO. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01429689-P1
08/03/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Ryan Hansen
08/03/2026
Special inspection requirement — Final
Dennis Mele
07/29/2026
Special inspection requirement — Structural Steel - High Strength Bolting
Ryan Hansen
07/29/2026
Special inspection requirement — Structural Steel - Details
Ryan Hansen
07/29/2026
Special inspection requirement — Final
Ryan Hansen
07/29/2026
Special inspection requirement — Post-installed Anchors
Ryan Hansen
07/24/2026
Filed — Alteration CO
FILING FOR PLUMBING SCOPE OF WORK : FOR CONVERSION OF AN EXISTING MIXED-USE, 7-STORY, 3-FAMILY BUILDING, INTO A SINGLE-FAMILY RESIDENCE.
M01254461-P7
07/15/2026
Filed — Alteration
Filing for roof repair. No change to use, egress or occupancy.
M01221479-S3
07/14/2026
Filed — Alteration
PROTECTION PLATFORM DURING DEMO. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01429689-I1
07/14/2026
Permit issued — Protection and Mechanical Methods
M01429689-I1-PMM
07/13/2026
Filed — Alteration
SIDEWALK SHED, SUPPORTED SCAFFOLD & FENCE AS SHOWN ON DRAWINGS. NO CHANGE IN USE EGRESS OR OCCUPANCY. WE SHAL COMPLY WITH CHAPTER 33 OF 2022.
M01109109-P5
07/13/2026
Permit issued — Structural
M01254461-S2-ST
07/07/2026
Permit issued — General Construction
M01221479-S2-GC
07/06/2026
Permit issued — General Construction
M01254461-I1-GC
06/30/2026
Permit issued — General Construction
M01221479-I1-GC
05/06/2026
Filed — Alteration
SIDEWALK SHED, SUPPORTED SCAFFOLD & FENCE AS SHOWN ON DRAWINGS. NO CHANGE IN USE EGRESS OR OCCUPANCY. WE SHAL COMPLY WITH CHAPTER 33 OF 2022.
M01109109-P4
04/29/2026
Filed — Alteration
SIDEWALK SHED, SUPPORTED SCAFFOLD & FENCE AS SHOWN ON DRAWINGS. NO CHANGE IN USE EGRESS OR OCCUPANCY. WE SHAL COMPLY WITH CHAPTER 33 OF 2022.
M01109109-P3
04/29/2026
Violation issued (HPD, open)
A
04/21/2026
Violation issued (ECB, closed)
Unknown
04/21/2026
Violation issued (ECB, closed)
Construction
04/21/2026
Violation issued (ECB, closed)
Construction
04/21/2026
Inspection — Pass-Final Sign Permit Inspection
Pass
View inspection ↗
04/16/2026
Inspection — Certified StandPipe - SD - Alarm Sys 64/09 - Finish
Certified
View inspection ↗
04/16/2026
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
04/15/2026
Filed — Alteration CO
FILING FOR PLUMBING SCOPE OF WORK : FOR CONVERSION OF AN EXISTING MIXED-USE, 7-STORY, 3-FAMILY BUILDING, INTO A SINGLE-FAMILY RESIDENCE.
M01254461-P3
Latest 60 of 192 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersPermit IssuedFIVE BOROUGH NYC LLC09/22/2026
DOB NOWStandpipePermit IssuedFIVE BOROUGH NYC LLC09/22/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedJAYLEX NYC CORP08/25/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedJAYLEX NYC CORP07/14/2026
DOB NOWStructuralPermit IssuedCOW BAY SPRINKLER CORP07/13/2026
DOB NOWGeneral ConstructionPermit IssuedCOW BAY SPRINKLER CORP07/07/2026
DOB NOWGeneral ConstructionPermit IssuedCOW BAY SPRINKLER CORP07/06/2026
DOB NOWGeneral ConstructionPermit IssuedCOW BAY SPRINKLER CORP06/30/2026
DOB NOWStructuralPermit IssuedCOW BAY SPRINKLER CORP03/20/2026
DOB NOWGeneral ConstructionPermit IssuedCOW BAY SPRINKLER CORP03/11/2026
DOB NOWSupport of ExcavationPermit IssuedCOW BAY SPRINKLER CORP02/06/2026
DOB NOWStandpipePermit IssuedFIVE BOROUGH NYC LLC02/04/2026
DOB NOWMechanical SystemsPermit IssuedDYNAIRE01/22/2026
DOB NOWFoundationPermit IssuedCOW BAY SPRINKLER CORP12/30/2025
DOB NOWGeneral ConstructionPermit IssuedCOW BAY SPRINKLER CORP12/16/2025
DOB NOWProtection and Mechanical MethodsPermit IssuedJAYLEX NYC12/11/2025
DOB NOWProtection and Mechanical MethodsPermit IssuedJAYLEX NYC12/03/2025
DOB NOWPlumbingPermit IssuedMACCARONE PLUMBING INC12/01/2025
DOB NOWMechanical SystemsPermit IssuedDYNAIRE11/06/2025
DOB NOWConstruction FencePermit IssuedJAYLEX NYC10/23/2025
DOB NOWSupported ScaffoldPermit IssuedJAYLEX NYC10/23/2025
DOB NOWConstruction FencePermit IssuedJAYLEX NYC10/22/2025
DOB NOWSprinklersPermit IssuedFIVE BOROUGH NYC LLC09/25/2025
DOB NOWSprinklersPermit IssuedFIVE BOROUGH NYC LLC09/25/2025
DOB NOWGeneral ConstructionPermit IssuedCOW BAY SPRINKLER CORP07/03/2025
DOB NOWGeneral ConstructionPermit IssuedCOW BAY SPRINKLER CORP03/07/2025
DOB NOWProtection and Mechanical MethodsPermit IssuedJAYLEX NYC11/14/2024
DOB NOWSupported ScaffoldPermit IssuedJAYLEX NYC10/30/2024
DOB NOWSupported ScaffoldPermit IssuedJAYLEX NYC10/30/2024
DOB NOWConstruction FencePermit IssuedJAYLEX NYC10/30/2024
BISEQISSUEDCOW BAY SPRINKLER CORP05/08/2018
BISOTISSUEDCOW BAY SPRINKLER CORP07/14/2017
BISEQISSUEDCOW BAY SPRINKLER CORP05/03/2017
BISOTISSUEDCOW BAY SPRINKLER CORP05/02/2017
BISOTISSUEDUB CONSTRUCTION INC03/13/2017
BISEQISSUEDUB CONSTRUCTION INC03/13/2017
BISEQISSUEDPERIMETER BRIDGE & SCAFFOLD09/21/2007
BISOTISSUEDZIRUALE CONSTRUCTION INC01/17/2007
BISBLISSUEDPP COUSIN INC07/13/2005
BISPLISSUEDPP COUSIN INC07/12/2005
+ 6 more permits on file
1 project · most recent 07/24/2026
Generators Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/24/2026Permit IssuedCOW BAY SPRINKLER CORPGenerators, Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PEFY-P18NMAU 18,000 BTU · Vrf Indoor ×21
PEFY-P12NMAU 12,000 BTU · Vrf Indoor ×15
PEFY-P24NMAU 24,000 BTU · Vrf Indoor ×14
PFFY-P12NEMU 12,000 BTU · Vrf Indoor ×12
PEFY-P30NMAU 30,000 BTU · Vrf Indoor ×6
PFFY-P18NEMU 18,000 BTU · Vrf Indoor ×6
PVFY-P18NAMU 18,000 BTU · Vrf Indoor ×6
PFFY-P12NRMU 12,000 BTU · Vrf Indoor ×3
PKFY-P12NLMU 12,000 BTU · Vrf Indoor ×3
PMFY-P06NBMU 6,000 BTU · Vrf Indoor ×3
PVFY-P12E00A 12,000 BTU · Vrf Indoor ×2
PURY-EP240TNU-A1 224,000 BTU · Vrf Outdoor ×2
PEFY-P24NMAU-E4 24,000 BTU · Vrf Indoor ×1
Ventilation
Renewaire EV PREMIUM M 100 CFM · Erv ×36
HE-05-JINV-S11EE---GNT---L 250 CFM · Erv ×6
Desertaire LV03 20,000 BTU · Ahu ×3
Generators
Cummins C100N6 100 kW · Generator ×1
1 project · most recent 07/24/2026
Sprinkler System
FiledStatusContractorScope
07/24/2026Permit IssuedFIVE BOROUGH NYC LLCSprinkler System
1 project · most recent 07/24/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/24/2026Permit IssuedMACCARONE PLUMBING INCGas, Storm, Water/Sanitary
6 projects · most recent 09/17/2026
General Wiring
FiledStatusContractorScope
09/17/2026Permit IssuedAPOLLO ELECTRIC INC.General Wiring
03/10/2026Permit IssuedTUXEDO ELEC'L CONTR'G INC—
02/24/2026Permit IssuedLIT MODE ELECL CONTG INC—
01/13/2026Permit IssuedAPOLLO ELECTRIC INC.—
04/15/2025Permit IssuedXELA ELECTRICAL CORP—
10/31/2024Permit IssuedHIGH QUALITY ELECTRIC OF—
3 projects · most recent 08/11/2026
Steel Concrete
FiledStatusContractorScope
08/11/2026Permit IssuedCOW BAY SPRINKLER CORP1 scope_items
07/24/2026Permit IssuedFIVE BOROUGH NYC LLCSteel, Concrete
07/17/2025Permit IssuedCOW BAY SPRINKLER CORP1 scope_items
1 project · most recent 07/13/2026
Fence Scaffold Sidewalk Shed
FiledStatusContractorScope
07/13/2026Permit IssuedJAYLEX NYC CORPFence, Scaffold, Sidewalk Shed
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/21/2026Pass-Final Sign Permit InspectionPassView ↗
04/16/2026Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
04/16/2026Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
02/13/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/23/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 62
DateRequirementInspectorRole
09/14/2026Sprinkler SystemsMatthew Bendixspecial
09/14/2026Standpipe SystemsMatthew Bendixspecial
09/14/2026Fire-Resistant Penetrations and JointsMatthew Bendixspecial
09/14/2026Fire-Resistant Penetrations and JointsMatthew Bendixspecial
08/14/2026Air barrier - visual inspection—energy_progress
08/14/2026Fenestration and door U-factor and product ratings—energy_progress
08/14/2026Insulation placement and R values—energy_progress
08/14/2026Mastic and Intumescent Fire-resistant Coatings—special
08/14/2026Sprayed fire-resistant materials—special
08/14/2026Energy Code Compliance Inspections—progress
08/14/2026Fire-Resistant Penetrations and Joints—special
08/14/2026FinalDennis Meleprogress
08/14/2026Masonry—special
08/14/2026Fire-Resistance Rated Construction—progress
08/14/2026Structural Stability – Alterations of existing buildingsRyan Hansenspecial
08/04/2026Fenestration and door U-factor and product ratings—energy_progress
08/04/2026Masonry—special
08/04/2026Mastic and Intumescent Fire-resistant Coatings—special
08/04/2026Fire-Resistant Penetrations and Joints—special
08/04/2026Sprayed fire-resistant materials—special
08/04/2026Energy Code Compliance Inspections—progress
08/04/2026Fire-Resistance Rated Construction—progress
08/04/2026Insulation placement and R values—energy_progress
08/04/2026Air barrier - visual inspection—energy_progress
08/03/2026FinalDennis Meleprogress
Latest 25 of 62.
▾Documents — 180 on file (BIS + DOB NOW)
▸Plans & Drawings35
▸DOB NOWPlans/Sketch35
08/25/2026M01447733-I1Request digital key ↗
08/25/2026M01130483-P1Request digital key ↗
08/25/2026M01130483-I1Request digital key ↗
Showing 3 of 35 on file for this type
▸Applications & Permits31
▸DOB NOWLPC Approval/Permit24
08/21/2026M01254461-P7Open ↗
08/21/2026M01254461-P8Open ↗
08/21/2026M01254461-P5Open ↗
Showing 3 of 24 on file for this type
▸BISWORK PERMIT APPLICATION4
05/08/2018122902966Open ↗
05/10/2017122902966Open ↗
05/09/2017122902966Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
02/11/2019122902966Open ↗
01/31/2019122902966Open ↗
10/06/2016122902966Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026M01254461-I1Open ↗
▸Seals & Professional Certifications68
▸DOB NOWDPL-1: Design Professional Seal & Signature35
08/25/2026M01447733-I1Open ↗
08/25/2026M01130483-I1Open ↗
08/25/2026M01130483-P1Open ↗
Showing 3 of 35 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature16
09/23/2026M01254461-S5Open ↗
09/23/2026M01254461-S1Open ↗
09/10/2026M01254461-P5Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
09/23/2026M01254461-S1Open ↗
09/10/2026M01254461-P5Open ↗
09/02/2026M01221479-S1Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
03/05/2019122902966Open ↗
03/05/2019122902966Open ↗
10/06/2016122902966Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/06/2016122902966Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/06/2016122902966Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026M01254461-I1Open ↗
▸Environmental & Asbestos24
▸DOB NOWDEP ACP-5: Asbestos Assessment Report23
08/21/2026M01254461-S2Open ↗
08/21/2026M01254461-S1Open ↗
08/21/2026M01254461-I1Open ↗
Showing 3 of 23 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/06/2016122902966Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
10/06/2016122902966Open ↗
10/06/2016122902966Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
03/05/2019122902966Open ↗
▸Approvals, Objections & Sign-offs5
▸BISLANDMARKS APPROVAL1
03/05/2019122902966Open ↗
▸BISCONSTRUCTION CODE DETERMINATION1
02/11/2019122902966Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
05/10/2017122902966Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
03/05/2019122902966Open ↗
▸DOB NOWDEP Variance (V5) letter1
08/13/2026M01221479-I1Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
03/05/2019122902966Open ↗
02/11/2019122902966Open ↗
10/06/2016122902966Open ↗
▸Filing & Intake Forms5
▸BISADDITIONAL INFORMATION2
02/11/2019122902966Open ↗
01/31/2019122902966Open ↗
▸BISBOROUGH INTAKE FORM2
03/05/2019122902966Open ↗
01/31/2019122902966Open ↗
▸BISEFILING COVER SHEET1
10/06/2016122902966Open ↗
▸Other Documents4
▸DOB NOWProof of Historic Building2
08/13/2026M01254461-I1Open ↗
08/13/2026M01221479-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026M01254461-S8Open ↗
▸DOB NOWProperty Ownership Certification1
08/21/2026M01254461-I1Open ↗