← Back
Two family frame
101 HASTINGS STREET
STATEN ISLAND · BIN 5148333
💬 Discuss this project
2011Year Built
2Stories
B2Building Class
R3-1Zoning
2,150 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 4,000 sf lot · 0.54 FAR built · Flood zone X
Locations of Work
Architecture
Roof2p · 1 filing · 7 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC101/25/2024
ALFRED V SAULO, ARCHITECT PC207/28/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S R SOLAR DESIGN203/21/2026
VSS CONSULTANTS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SEA BRIGHT SOLAR LLCGeneral Contractor303/21/2026
AVS CONSTRUCTION MGMT INCGeneral Contractor207/08/2026
TITANIUM PLBG & HTG, INCPlumbing203/22/2026
AMBER ELECTL CONTNG INCElectrical103/22/2026
ANTONIO TZOUMASElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244101/25/2024
Building Lifecycle
All (22)Filed (3)Permit Issued (3)Signed Off (3)Violation (5)Inspection (3)Special Inspection (5)
04/02/2024
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK.
S00992242-I1
01/30/2024
Permit issued — Solar
S00992242-I1-SL
01/25/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK.
S00992242-I1
01/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
01/18/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
01/18/2024
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
01/18/2024
Special inspection requirement — Final
NARESH MAHANGU
01/18/2024
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
10/10/2023
Signed off — Alteration
Application filed to obtain curb cut number. for 10' CURB CUT (w/2-18" SPLAYS)102.39 FT NORTH FROM THE INTERSECTION OF MCCLEAN AVE . and HASTING STREET.
S00911304-I1
10/06/2023
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
08/07/2023
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
08/02/2023
Permit issued — Curb Cut
S00911304-I1-CC
07/28/2023
Filed — Alteration
Application filed to obtain curb cut number. for 10' CURB CUT (w/2-18" SPLAYS)102.39 FT NORTH FROM THE INTERSECTION OF MCCLEAN AVE . and HASTING STREET.
S00911304-I1
03/02/2023
Signed off — Alteration
S00689475-I1
03/01/2023
Inspection — Pass-Final Fence Non-Directive 14
Pass
View inspection ↗
02/21/2023
Permit issued — Construction Fence
S00689475-I1-FN
03/16/2022
Filed — Alteration
S00689475-I1
12/29/2009
Violation issued (ECB, closed)
Construction
12/29/2009
Violation issued (ECB, closed)
Construction
03/26/2009
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
03/26/2009
Violation issued (ECB, closed)
Unknown
03/26/2009
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSEA BRIGHT SOLAR LLC01/30/2024
DOB NOWCurb CutSigned-offAVS CONSTRUCTION MGMT INC08/02/2023
DOB NOWConstruction FenceSigned-offAVS CONSTRUCTION MGMT INC02/21/2023
BISPLISSUEDTITANIUM PLBG & HTG, INC12/28/2021
BIS—ISSUEDAVS CONSTRUCTION MGMT INC10/26/2020
BIS—ISSUEDALKA CONTRACTING INC02/25/2010
BIS—ISSUEDRELIABLE ROOFING LLC04/17/2009
BISPLISSUEDK.M.D MECHANICAL 1443 LLC12/01/2008
BIS—ISSUEDRELIABLE CONTRACTING LLC09/04/2007
BISPLISSUEDEAGLE PLUMBING & HEATING OF SI03/27/2006
BIS—ISSUEDRELIABLE CONTRACTING11/09/2005
BISEQISSUEDETNA CONTRACTING INC11/09/2005
1 project · most recent 01/22/2024
FiledStatusContractorScope
01/22/2024CompleteAMBER ELECTL CONTNG INC—
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
10/06/2023Pass-Final Curb Cut Non-Directive 14PassView ↗
08/07/2023Fail-Final Curb Cut Non-Directive 14FailView ↗
03/01/2023Pass-Final Fence Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
01/18/2024Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
01/18/2024Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
01/18/2024Energy Code Compliance InspectionsNARESH MAHANGUprogress
01/18/2024FinalNARESH MAHANGUprogress
01/18/2024Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 74 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026S00689475-I1Request digital key ↗
08/22/2026S00911304-I1Request digital key ↗
08/21/2026S00992242-I1Request digital key ↗
▸Applications & Permits28
▸BISPLAN / WORK APPROVAL APPLICATION23
10/17/2023500848238Open ↗
10/11/2023500848238Open ↗
10/04/2023500848238Open ↗
Showing 3 of 23 on file for this type
▸BISWORK PERMIT APPLICATION3
12/28/2021500848238Open ↗
10/26/2020500848238Open ↗
10/26/2020500848238Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
10/13/2020500848238Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
02/28/2022500848238Open ↗
▸Zoning, Tax Lot & Property Records2
▸BISVERIFY TAX LOT1
07/28/2023500848238Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
07/28/2023500848238Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026S00689475-I1Open ↗
08/22/2026S00911304-I1Open ↗
08/13/2026S00992242-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/02/2026S00992242-I1Open ↗
09/02/2026S00992242-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/23/2020520395661Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/02/2026S00992242-I1Open ↗
▸Trade Schedules & Equipment8
▸BISSCHEDULE B - PLUMBING5
10/28/2021500848238Open ↗
10/26/2021500848238Open ↗
09/30/2021500848238Open ↗
Showing 3 of 5 on file for this type
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION2
12/19/2022500848238Open ↗
12/19/2022500848238Open ↗
▸BISLAMINATED I BEAM-NOTIFICATION TO FDNY1
01/11/2023500848238Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: EXEMPTION (ASB4)1
09/23/2020520395661Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026S00992242-I1Open ↗
▸Inspections & Test Reports6
▸BIS* STRUCTURAL STABILITY 1 RCNY:16-011
01/11/2023500848238Open ↗
▸BIS* DRYWELL INST RET/DET : TR1-DRYWELL RS16-P110.131
01/11/2023500848238Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
03/14/2023500629331Open ↗
▸BIS* * BORINGS / TEST PITS (TR-4) 27-7201
11/02/2023500848238Open ↗
▸BIS* SOIL PERCOLATE TEST-DRY WELL RS16-P1131
01/11/2023500848238Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
10/30/2023500848238Open ↗
▸Approvals, Objections & Sign-offs9
▸BISSCHEDULE A - OCCUPANCY / USE6
10/11/2023500848238Open ↗
10/02/2023500848238Open ↗
08/04/2023500848238Open ↗
Showing 3 of 6 on file for this type
▸BISBPP: FINAL SIGNOFF1
05/03/2023500629331Open ↗
▸BISSUPERSEDING LETTER1
10/26/2020500848238Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026S00992242-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT (FINAL): PW31
10/02/2023500848238Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
10/25/2023500848238Open ↗
11/15/2022500643351Open ↗
▸BISBOROUGH INTAKE FORM1
12/28/2021500848238Open ↗
▸BISEFILING COVER SHEET1
09/23/2020520395661Open ↗
▸Other Documents4
▸BISLAA - Supporting Documentation1
12/28/2021500848238Open ↗
▸BIS* FIRE STOPS 27-3451
01/11/2023500848238Open ↗
▸BIS* LAMINATED WOOD TABLE 10-21
01/11/2023500848238Open ↗
▸BIS* * SUBGRADE 27-723,DIRC 15/711
01/11/2023500848238Open ↗