← Back
Two family frame
1015 HART STREET
BROOKLYN · Bushwick (West) · BIN 3073295
💬 Discuss this project
1930Year Built
2Stories
B2Building Class
R6Zoning
1,800 sfGross Floor Area
2Units
Two family frame · 1,350 sf lot · 1.33 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction18p · 1 filing · 20 docs
Floor 1Under Construction12p · 1 filing · 20 docs
CellarUnder Construction18p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/12/2023$1.3M—— → —$706/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALEX SHUEY203/17/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DEVANG ARVIND SHAH103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MSV BUILDERS LLCGeneral Contractor107/08/2026
MONARCH PLUMB & HTG LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JIAN ENGINEERING PLLC7397203/17/2026
Building Lifecycle
All (64)Filed (2)Permit Issued (2)Objection (30)Special Inspection (30)
06/15/2026
Permit issued — Plumbing
B01165763-S1-PL
06/10/2026
Permit issued — Mechanical Systems
B01165763-I1-GC
04/13/2026
Objection resolved — Resolved
03/24/2026
Objection raised — Energy
03/17/2026
Filed — Alteration CO
ALTERATION OF AN EXISTING TWO-FAMILY INTO A SINGLE FAMILY RESIDENCE TO INCLUDE: LAYOUT CHANGE OF NON-LOAD BEARING PARTITIONS; REPLACEMENT OF EXTERIOR WINDOW WITH DOOR; INSTALL SKYLIGHT, STEEL FRAMED DECK WITH STAIRS TO REAR YARD, SPLIT HEAT PUMP SYSTEM
B01165763-S1
03/13/2026
Special inspection requirement — Maintenance information
Alex Shuey
03/13/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
JIAN DENG
03/13/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Alex Shuey
03/13/2026
Special inspection requirement — HVAC-R and service water heating equipment
Alex Shuey
03/13/2026
Special inspection requirement — HVAC-R and service water heating system controls
Alex Shuey
01/30/2026
Objection resolved — Addressed
01/30/2026
Objection resolved — Addressed
12/17/2025
Objection resolved — Addressed
12/17/2025
Objection resolved — Addressed
12/17/2025
Special inspection requirement — Energy Code Compliance Inspections
Alex Shuey
11/04/2025
Objection resolved — Addressed
07/30/2025
Objection raised — Cost
07/18/2025
Objection resolved — Addressed
07/18/2025
Objection resolved — Addressed
07/18/2025
Objection resolved — Addressed
07/18/2025
Objection resolved — Addressed
07/18/2025
Objection resolved — Addressed
04/17/2025
Objection raised — Structural
04/17/2025
Objection raised — Scope
04/17/2025
Objection raised — Scope
04/08/2025
Objection resolved — Addressed
03/21/2025
Objection resolved — Addressed
03/21/2025
Objection resolved — Addressed
03/21/2025
Objection resolved — Addressed
03/20/2025
Special inspection requirement — Air barrier - visual inspection
Alex Shuey
03/20/2025
Special inspection requirement — Ventilation and air distribution system
Alex Shuey
03/20/2025
Special inspection requirement — Metering
Alex Shuey
03/03/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
INDARDEO PARBHUNATH
03/03/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
JIAN DENG
02/04/2025
Objection raised — Structural
02/04/2025
Objection raised — Admin
02/04/2025
Objection raised — Zoning
02/04/2025
Objection raised — Zoning
02/04/2025
Objection raised — Admin
02/04/2025
Objection raised — Zoning
02/04/2025
Objection raised — Structural
02/04/2025
Objection raised — Structural
02/04/2025
Objection raised — Other
02/04/2025
Objection raised — Energy
01/24/2025
Filed — Alteration CO
ALTERATION OF AN EXISTING TWO-FAMILY INTO A SINGLE FAMILY RESIDENCE TO INCLUDE: LAYOUT CHANGE OF NON-LOAD BEARING PARTITIONS; REPLACEMENT OF EXTERIOR WINDOW WITH DOOR; INSTALL SKYLIGHT, STEEL FRAMED DECK WITH STAIRS TO REAR YARD, SPLIT HEAT PUMP SYSTEM
B01165763-I1
01/14/2025
Special inspection requirement — Fire-Resistance Rated Construction
Alex Shuey
01/14/2025
Special inspection requirement — Fenestration areas
Alex Shuey
01/14/2025
Special inspection requirement — HVAC-R and service water heating equipment
Alex Shuey
01/14/2025
Special inspection requirement — Structural Steel - High Strength Bolting
JIAN DENG
01/14/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Alex Shuey
01/14/2025
Special inspection requirement — Duct leakage testing, insulation and design
Alex Shuey
01/14/2025
Special inspection requirement — Fenestration air leakage
Alex Shuey
01/14/2025
Special inspection requirement — Permanent certificate
Alex Shuey
01/14/2025
Special inspection requirement — HVAC-R and service water heating system controls
Alex Shuey
01/14/2025
Special inspection requirement — Structural Steel - Welding
JIAN DENG
01/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JIAN DENG
01/14/2025
Special inspection requirement — Energy Code Compliance Inspections
Alex Shuey
01/14/2025
Special inspection requirement — Post-installed Anchors
JIAN DENG
01/10/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Alex Shuey
01/10/2025
Special inspection requirement — Mechanical Systems
JIAN DENG
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedMONARCH PLUMB & HTG LLC06/15/2026
DOB NOWMechanical SystemsPermit IssuedMSV BUILDERS LLC06/10/2026
1 project · most recent 03/17/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/17/2026Permit IssuedMSV BUILDERS LLCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric PMFY-P06NBMU-ER5 6,000 BTU · Vrf Indoor ×4
PEFY-P24NMAU-E4 24,000 BTU · Vrf Indoor ×1
PUMY-HP48NKMU 48,000 BTU · Vrf Outdoor ×1
1 project · most recent 03/17/2026
Gas Water/Sanitary
FiledStatusContractorScope
03/17/2026Permit IssuedMONARCH PLUMB & HTG LLCGas, Water/Sanitary
1 project · most recent 06/24/2026
General Wiring
FiledStatusContractorScope
06/24/2026Permit IssuedANI ELECTRIC CORPGeneral Wiring
1 project · most recent 03/17/2026
Steel Concrete
FiledStatusContractorScope
03/17/2026Permit IssuedMONARCH PLUMB & HTG LLCSteel, Concrete
▾Special Inspection Requirements (DOB NOW) — 31
DateRequirementInspectorRole
03/13/2026Maintenance informationAlex Shueyenergy_progress
03/13/2026Fire-Resistant Penetrations and JointsJIAN DENGspecial
03/13/2026HVAC-R and service water piping design and insulationAlex Shueyenergy_progress
03/13/2026HVAC-R and service water heating equipmentAlex Shueyenergy_progress
03/13/2026HVAC-R and service water heating system controlsAlex Shueyenergy_progress
12/17/2025Energy Code Compliance InspectionsAlex Shueyprogress
03/20/2025Air barrier - visual inspectionAlex Shueyenergy_progress
03/20/2025Ventilation and air distribution systemAlex Shueyenergy_progress
03/20/2025MeteringAlex Shueyenergy_progress
03/03/2025Subsurface Investigations (Borings/Test Pits)INDARDEO PARBHUNATHspecial
03/03/2025Structural Stability – Alterations of existing buildingsJIAN DENGspecial
01/14/2025Fire-Resistance Rated ConstructionAlex Shueyprogress
01/14/2025Fenestration areasAlex Shueyenergy_progress
01/14/2025HVAC-R and service water heating equipmentAlex Shueyenergy_progress
01/14/2025Structural Steel - High Strength BoltingJIAN DENGspecial
01/14/2025HVAC-R and service water piping design and insulationAlex Shueyenergy_progress
01/14/2025Duct leakage testing, insulation and designAlex Shueyenergy_progress
01/14/2025Fenestration air leakageAlex Shueyenergy_progress
01/14/2025Permanent certificateAlex Shueyenergy_progress
01/14/2025HVAC-R and service water heating system controlsAlex Shueyenergy_progress
01/14/2025Structural Steel - WeldingJIAN DENGspecial
01/14/2025Fire-Resistant Penetrations and JointsJIAN DENGspecial
01/14/2025Energy Code Compliance InspectionsAlex Shueyprogress
01/14/2025Post-installed AnchorsJIAN DENGspecial
01/10/2025Fenestration and door U-factor and product ratingsAlex Shueyenergy_progress
Latest 25 of 31.
▾Documents — 45 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026B01165763-S1Request digital key ↗
08/17/2026B01165763-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B01165763-I1Open ↗
▸Seals & Professional Certifications34
▸DOB NOWProgress Inspector Seal & Signature22
09/01/2026B01165763-S1Open ↗
09/01/2026B01165763-S1Open ↗
09/01/2026B01165763-S1Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/01/2026B01165763-S1Open ↗
08/25/2026B01165763-I1Open ↗
08/25/2026B01165763-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026B01165763-S1Open ↗
08/13/2026B01165763-S1Open ↗
08/13/2026B01165763-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist1
08/13/2026B01165763-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/17/2026B01165763-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/17/2026B01165763-S1Open ↗
08/13/2026B01165763-I1Open ↗
08/13/2026B01165763-S1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B01165763-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026B01165763-I1Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/13/2026B01165763-I1Open ↗