HPD06/17/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES FLOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
ECB04/29/2026(RTS) THE ONLY ELEVATOR IN SECTION OF BUILDING OR BUILDING IS OUT-OF-SERVICE. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT-OF-SERVICE CREATING A HAZARDOUS CONDITION AS PER 1RCNY 11-02. RESTORE TO SERVICE IMMED$625 due
ECB12/29/2025CLASS 2:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, ELEVATOR PHONE INOPERATIVE,CONNECT PHONE TO 24HRS EMERGENCY SERVICE.MAINTENAN$625 due
ECB06/26/2025CEASE USE ITEMS: 1) NON WORKING ZONE LOCK RESTRICTOR. 2) INOPERATIVE DLM. CLASS 2 ITEMS: REPLACE WRON GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. INOPERATIVE PHONE. ADJUST FLOOR STOPS. WORN CAB MIRROR.$1K due
DOB12/11/2024FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB11/06/2024FOUND SLANT FIN OIL FIRED BOILERS MODEL #TR-70, UNITS#3&4 NOT OPERABLE, ALSO HEAVY SOOT CONDITION ON TOP OF UNITS, HAVE UNITS SERVICED AND OBTAIN CERTIFICATE OF CORRECTION$625 due
ECB10/02/2024INOPERATIVE CAR PHONE. REPALCE WORN GIBS WHERE NEEDED. SEAL HOIST MACHINE LEAKS. ADJUST BASEMENT HOISTWAY DOOR ACCESS HOLE. ADJUST DOOR OPERATOR TO ENSURE PROPER OPERATION. MAINTENANCE LOG MISSING ENTRIES. ADJU$625 due
ECB06/14/2024IN-CAR COMMUNICATION INOPERATIVE. ADJUST CAR DOOR TO OPEN FULLY. PROVIDE ACCESS TO ELEVATOR MACHINE ROOM.$2K due
ECB05/08/2024RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION IN A SINGLE CAR DEVICE, A CEASE USE VIOLATION WAS ISSUED FOR, CAR DOOR RESTRICTOR, / DLM NOT WORKING, REMEDY; REPAIR THEN CONTACT NYCDOB FOR A RESTORE TO$3K due
DOB01/10/2024FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB11/22/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB10/10/2023CLASS 2: REPAIR IN-CAR EMERGENCY PHONE., REPAIR IN-CAR VENTILATION., REPAIR TOP OF CAR LIGHT., PROVIDE UP TO DATE ELEVATOR MAINTENNACE LOG BOOK (LAST ENTRY 04/2023)., CLEAN TOP OF CAR., CLASS 1: CEASE USE ITEMS$1K due
DOB10/04/2023FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB04/19/2023CLASS 2: PHONE INOPERATIVE REPAIR & PROGRAM TO 24 HR OPERATOR. CAR STATIONS BUTTONS DEFECTIVE CHECK WIRES & REPAIR. CAR STATION NOT TAGGED WITH NYC ID#. PROVIDE TAG. DOOR OPERATOR MISALIGNED. ADJUST FOR DOOR TO$625 due
ECB02/15/2023CLASS 1: UPON INSPECTION FOUND DEVICE TO BE OUT OF SERVICE. RESTORE TO SERVICE REPAIR IMMEDIATELY AS PER 1RCNY 11-02. CALL NYCDOB FOR INSPECTION WHEN RESTORED. CLASS 2: EVACUATION SIGNS MISSING. PROVIDE REQUIRE$1K due
DOB05/11/2022FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB12/22/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB03/03/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/06/2019VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
DOB03/21/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB01/26/2018VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
DOB12/13/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB11/29/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB11/14/2016VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
DOB05/15/2014VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
DOB10/07/1999V-DOB VIOLATION - ACTIVE
ECB02/09/2026CEASE USE ITEMS: CAR DOOR IS OUT OF SEQUENCE / ADJUSTMENT CAUSING AN ENTRAPMENT. PROVIDE CAR DOOR TO BE FULLY OPEN. EFEECT REPAIR. (2) HOISTWAY DOOR INTERLOCK ON THE TOP LANDING HAS BEEN TAMPERED WITH. CHECK FOHearing held — result not yet published$1K proposed
ECB02/11/2022CLASS 1 VIOLATION ISSUED,/ DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN SERVICE PRESENT IN CONTROLLER. INSTALL FIREMAN SERVICE SO DLM IS IN COMPLIANCE WITH SECTION 3. 10. 12 OF APPENDIX K3. CLASS 2 VIOLANothing owed — awaiting certificate of correction
ECB09/30/2021CLASS 1 VIOLATION ISSUED, NO FIRE SERVICE IN CONTROLLER AS PER CODE DLM AS TO WORK WITH FIREMAN SERVICE ON PHASE 1&2 IN FIRE SERVICE SYSTEM, PROVIDE, CLASS 2,FLOOR SELECTOR DEFECTIVE,REPAIRNothing owed — awaiting certificate of correction
ECB12/09/2020NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; INSTALL DLM AND PERFORM AND FILE TEST WITH NYCDOB. PHONE INOPERATIVE.Nothing owed — awaiting certificate of correction
ECB08/30/201867-X-10,39-O-02,80-M-07,72-T-07,08-V-01,16-T-07,56-Y-13,26-D-06.(67)REPAIR TWO WAY COMMUNICATION (39)CLEAN CAR TOP (80) PROVIDE RUNBY SIGNAGE (72)LABEL PIT STOP SWITCH (08)ELEVATOR NOT LEVEL (16)PROVIDE BRAILLENothing owed — awaiting certificate of correction
ECB12/19/201797X10,40M7. (97X)DEVICE INOPERATIVE UPON INSP ARRIVAL @ 5TH FLR W/ NO ALTERNATIVE SERVICE MUST REPAIR IMMEDIATELY. (40M)MUST PROVIDE KEYS FOR MACHINE ROOM SO A COMPLETE INSP CAN BE PERFORMED BY THE DEPT.Nothing owed — awaiting certificate of correction
ECB09/06/201743M03,05A10,05J10. 43M03-PROVIDE COVER PER REVERSE PHASE RELAY; 05A10-CAR DOOR RETROCT RALTERED REPAIR; 05J10-GAP IN CAR DOOR REPAIRCONTACT NYCDOB FOR REINSPECTION TO RETURN DEVICE INTO SERVICE SELECTORNothing owed — awaiting certificate of correction