← Back
Two stories - detached, small or mid-size
102-32 160 AVENUE
QUEENS · Howard Beach-Lindenwood · BIN 4295483
💬 Discuss this project
1920Year Built
2Stories
A1Building Class
R3AZoning
732 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,350 sf lot · 0.31 FAR built · Flood zone AE
Locations of Work
ArchitectureElectrical
Roof1p · 1 filing · 17 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC208/11/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854208/11/2025
Building Lifecycle
All (14)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (10)
09/18/2025
Signed off — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01214736-I1
08/12/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
08/12/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
08/12/2025
Special inspection requirement — Final
TOM PETERSEN
08/12/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
08/12/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
08/11/2025
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01214736-P1
08/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
08/11/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
08/11/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
08/11/2025
Special inspection requirement — Final
TOM PETERSEN
08/11/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
04/24/2025
Permit issued — Solar
Q01214736-I1-SL
04/23/2025
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01214736-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP04/24/2025
1 project · most recent 04/22/2025
FiledStatusContractorScope
04/22/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
08/12/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
08/12/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
08/12/2025FinalTOM PETERSENprogress
08/12/2025Energy Code Compliance InspectionsTOM PETERSENprogress
08/12/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
08/11/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
08/11/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
08/11/2025Energy Code Compliance InspectionsTOM PETERSENprogress
08/11/2025FinalTOM PETERSENprogress
08/11/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026Q01214736-I1Request digital key ↗
08/20/2026Q01214736-P1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
09/25/2026Q01214736-I1Open ↗
09/25/2026Q01214736-I1Open ↗
09/25/2026Q01214736-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/25/2026Q01214736-I1Open ↗
09/25/2026Q01214736-I1Open ↗
08/29/2026Q01214736-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026Q01214736-I1Open ↗
08/13/2026Q01214736-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026Q01214736-I1Open ↗
08/13/2026Q01214736-P1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01214736-I1Open ↗