DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB03/11/2002V-DOB VIOLATION - ACTIVE
DOB01/13/1997V-DOB VIOLATION - ACTIVE
ECB05/05/2026REISSUE ON ECB#35720960K FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:CONCRETE CEILING WITH SEVERAL LINEAR STRESS CRACK IN OLD GIRLS LOCKER ROOM NOW USED AS STORAGE OBSERVED UPON INSPECTION.REM:RNothing owed — awaiting certificate of correction
ECB05/05/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:EMERGENCY ILLUMINATED DISCHARGE EXIT LIGHTS AND EXIT SIGNS NOT OPERATINothing owed — awaiting certificate of correction
ECB05/05/2026FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8;27-371(J).NOTED:ILLEGAL KICK STOPS INSTALLED ON FIRE RATED CLASSROOMS AND SMOKE DOORS ON SMOKE DOOR SNothing owed — awaiting certificate of correction
ECB05/05/2026EXIT DOOR NOT SELF-CLOSING.NOTED:EMERGENCY EXTERIOR EXIT DOOR NOT SELFCLOSING DUE TO BINDING,MISSING AND OR FAULTY HARDWARE ON EXTERIOR EXITDOOR AT EXIT 2 1ST FL,EXIT 3 1ST FL,AND EXIT 10 1ST FL OBSERVED UPON INothing owed — awaiting certificate of correction
ECB05/05/2026EXIT DOOR NOT SELF-CLOSING.NOTED:EMERGENCY EXTERIOR EXIT DOOR NOT SELFCLOSING DUE TO BINDING,MISSING AND OR FAULTY HARDWARE AT EXIT 1 EXTERIOR DOOR AT MINI SCHOOL OBSERVED UPON INSPECTION.REM:REPAIR/REPLACE DOONothing owed — awaiting certificate of correction
ECB05/05/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FIRE RATEDCLASSROOMS AND SMOKE DOORS NOT SELF CLOSING DUE TO BINDING,MISSING ANDOR FAULTY HARDWARE ON CLASSROOMS,429,426,427,424-2 DOORS,418,411,302,3Nothing owed — awaiting certificate of correction
ECB05/05/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FIRE RATEDCLASSROOMS AND SMOKE DOORS NOT SELF-CLOSING DUE TO BINDING,MISSING ANDOR FAULTY HARDWARE ON SMOKE DOORS AT EXIT 3(1)DOOR AND EXIT 2(2)DOORSNothing owed — awaiting certificate of correction
ECB05/05/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:EMERGENCY ILLUMINATED DISCHARGE EXIT LIGHTS AND EXIT SIGNS NOT WORKINGNothing owed — awaiting certificate of correction
ECB05/05/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:CRACKED WIRE MESH GLASS VISION PANEL ON SMOKE DOOR IN GYM,AND CRACKED WIRE MESH VISION PANEL ON SMOKE DOOR AT STAIR E 1ST FL AND CRACKED GLASS AT TROPNothing owed — awaiting certificate of correction
ECB08/28/2025REISSUE: 35672232Z-FAILURE TO MAINTAIN BUILDINGS IN CODE-COMPLIANT MANNER:MINI SCHOOL CLASSROOM DOOR/ARE NOT SELF-CLOSING THROUGHOUT ENTIRE.REMEDY: COMPLY WITH CODE.Nothing owed — awaiting certificate of correction
ECB08/28/2025REISSUE: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: CRACKED CONCRETE @ CEILING IN OLD GIRLS LOCKER ROOM. REMEDY: COMPLY WITH CODE.Nothing owed — awaiting certificate of correction
ECB09/19/2024FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OLD GIRLS LOCKERROOM CRACK IN CONCRETE CEILING.REM:REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB05/16/2023REISSUE#35663117Z-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED AT MINI-SCHOOL,CLASSROOM DOORS(APPROX.70%)ARE NOT SELF-CLOSING DUE TO MISSING HARDWARE.REM:REPAIR AND/OR REPLACE,INSTALL SENothing owed — awaiting certificate of correction
ECB06/15/2022REISSUED#35502422H FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:NOTED:OBSERVED THROUGHOUT MINI-SCHOOL,APPROX.70% OF CLASSROOM DOORSDON'T CLOSE PROPERLY DUE TO MISSING DOOR CLOSING HARDWARE.REM:REPAIR ANothing owed — awaiting certificate of correction
ECB07/21/2021REISSUE#35500795L FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: UPON INSPECTION OBSERVED AT THE MINI-SCHOOL MORE THAN 1/2 OF THESCHOOL HAS DOORS W/DEFECTIVE &/OR MISSING THE SELF CLOSER HARDWARE E.GNothing owed — awaiting certificate of correction
ECB06/24/2020FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED OBSERVED AT MINI SCHOOL CLASS ROOM DOORS AT ROOM 2,18 DO NOT CLOSE PROPERLY DUE TO MISSING DOOR CLOSER HARDWARE REPAIR AND OR REPLACENothing owed — awaiting certificate of correction