← Back
Elevator apt, semi-fireproof with stores
1022 3RD AVENUE
MANHATTAN · BIN 1091872
💬 Discuss this project
2023Year Built
31Stories
D7Building Class
C1-9Zoning
117,307 sfGross Floor Area
109Units
Rent Stabilized0 Open Violations
Elevator apt, semi-fireproof with stores · Owner of record: THIRD NORTH HOLDINGS LLC · 4,420 sf lot · 26.54 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneralOther
Roof9p · 1 filing · 4 docs
Floor 281p · 1 filing · 6 docs
Floor 27
Floor 26
Floor 25
Floor 24
Floor 231p · 1 filing · 2 docs
Floor 22
Floor 21
Floor 201p · 1 filing · 2 docs
Floor 19
Floor 18
Floor 17
Floor 16
Floor 151p · 1 filing · 2 docs
Floor 14
Floor 13
Floor 12
Floor 11
Floor 10
Floor 9
Floor 8
Floor 7
Floor 61p · 1 filing · 2 docs
Floor 5107p · 1 filing · 20 docs
Floor 4103p · 3 filings · 20 docs
Floor 3105p · 2 filings · 20 docs
Floor 2107p · 4 filings · 20 docs
Floor 1101p · 2 filings · 20 docs
Cellar105p · 3 filings · 20 docs
1 job · most recent 04/22/2026
Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/22/2026Permit IssuedTHIRD NORTH GC LLCHeating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Heat / Cool
Hitachi HVAHR096B32S 96,000 BTU · Vrf Outdoor ×34
HVAHR120B32S 120,000 BTU · Vrf Outdoor ×28
HVAHR144B32S 144,000 BTU · Vrf Outdoor ×13
HVAHR168B32S 168,000 BTU · Vrf Outdoor ×7
RAS-4.0PNNBDH1 36,000 BTU · Condensing Unit ×1
HIDM012B23S 12,000 BTU · Vrf Indoor ×1
HIDM015M23S 15,000 BTU · Vrf Indoor ×1
HIDM018B23S 18,000 BTU · Vrf Indoor ×1
HIDM024B23S 24,000 BTU · Vrf Indoor ×1
HIDM027B23S 27,000 BTU · Vrf Outdoor ×1
HIDM030B23S 30,000 BTU · Vrf Indoor ×1
HIDM036B23S 36,000 BTU · Vrf Indoor ×1
HIDM048B23S 48,000 BTU · Vrf Indoor ×1
Daikin RXYQ144XATJA 144,000 BTU · Vrf Outdoor ×24
Aaon RN-015-8-0-K60E-14A 237,040 BTU · Doas ×4
United Cool Air AAH200G#ASTA1 182,338 BTU · Doas ×4
Heating
Daikin BWLP350BR 144,000 BTU · Heat Pump Outdoor ×18
Spacepak ILAHP48 53,214 BTU · Heat Pump Outdoor ×16
Ventilation
Greenheck N/A 3,649 CFM ×4
2 jobs · most recent 04/22/2026
Sprinkler System
FiledStatusContractorScope
04/22/2026Signed-offSTAT FIRE SPRINKLER NYC CSprinkler System
11/21/2022———
2 jobs · most recent 04/22/2026
Gas Water/Sanitary Storm
FiledStatusContractorScope
04/22/2026Signed-offFORWARD MECHANICAL CORPGas, Storm, Water/Sanitary
01/28/2021Signed-offTMS PLBG & HEATING CORPGas, Water/Sanitary
10 jobs · most recent 12/22/2025
General Wiring
FiledStatusContractorScope
12/22/2025CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
09/30/2025CompleteJAM ELECTRICAL CORP—
04/26/2024CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
04/10/2024CompletePOWER SURGE ELECTRIC, INC1 meters, 1 new_meters
03/11/2024CompletePOWER SURGE ELECTRIC, INC—
02/23/2024CompleteNASH ELECTRIC SERVICES IN—
01/22/2024CompleteNASH ELECTRIC SERVICES IN—
10/17/2023CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
12/27/2022CompleteILLUMINOUS ELECTRIC CORP.General Wiring
04/20/2021Permit IssuedTRIPLE T ELECTRIC INCGeneral Wiring
1 job · most recent 04/22/2026
Steel Concrete Masonry
FiledStatusContractorScope
04/22/2026Signed-offFORWARD MECHANICAL CORPSteel, Concrete, Masonry
Building Lifecycle
All (236)Filed (49)Permit Issued (44)Signed Off (18)Violation (9)Inspection (20)Objection (66)Special Inspection (30)
07/16/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/27/2026
Special inspection requirement — Fenestration areas
PATRICK ORRICO
04/27/2026
Special inspection requirement — Protection of exposed foundation insulation
CHUNG CHING JEN
04/27/2026
Special inspection requirement — Air barrier continuity plan testing
CHUNG CHING JEN
04/27/2026
Special inspection requirement — Vestibules
CHUNG CHING JEN
04/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHUNG CHING JEN
04/27/2026
Special inspection requirement — Masonry
CHUNG CHING JEN
04/27/2026
Special inspection requirement — Insulation placement and R values
CHUNG CHING JEN
04/27/2026
Special inspection requirement — Air barrier - visual inspection
CHUNG CHING JEN
04/27/2026
Special inspection requirement — Fenestration air leakage
PATRICK ORRICO
04/27/2026
Special inspection requirement — Fire-Resistance Rated Construction
CHUNG CHING JEN
04/27/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
PATRICK ORRICO
04/27/2026
Special inspection requirement — Energy Code Compliance Inspections
CHUNG CHING JEN
04/27/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
CHUNG CHING JEN
04/22/2026
Filed — New Building
Plumbing work as shown on plans filed herewith.
M00683925-B6
04/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHUNG CHING JEN
04/22/2026
Special inspection requirement — Air barrier - visual inspection
CHUNG CHING JEN
04/22/2026
Special inspection requirement — Masonry
CHUNG CHING JEN
04/22/2026
Special inspection requirement — Protection of exposed foundation insulation
CHUNG CHING JEN
04/22/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
CHUNG CHING JEN
04/22/2026
Special inspection requirement — Fenestration air leakage
PATRICK ORRICO
04/22/2026
Special inspection requirement — Fenestration areas
PATRICK ORRICO
04/22/2026
Special inspection requirement — Air barrier continuity plan testing
CHUNG CHING JEN
04/22/2026
Special inspection requirement — Insulation placement and R values
CHUNG CHING JEN
04/22/2026
Special inspection requirement — Fire-Resistance Rated Construction
CHUNG CHING JEN
04/22/2026
Special inspection requirement — Energy Code Compliance Inspections
CHUNG CHING JEN
04/22/2026
Special inspection requirement — Vestibules
CHUNG CHING JEN
04/22/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
PATRICK ORRICO
04/16/2026
Signed off — Alteration
This application is filed for a Temporary Use Permit for a sales office including model units pursuant to section AC 28-111 and Buildings Bulletin 2010-002. Filed in conjunction with NB #M00683925-I1.
M01237475-I1
04/15/2026
Signed off — New Building
Plumbing work as shown on plans filed herewith.
M00683925-S9
12/22/2025
Signed off — New Building
Plumbing work as shown on plans filed herewith.
M00683925-S7
12/22/2025
Signed off — New Building
Plumbing work as shown on plans filed herewith.
M00683925-S8
12/22/2025
Signed off — New Building
Plumbing work as shown on plans filed herewith.
M00683925-Z1
12/03/2025
Filed — New Building
Plumbing work as shown on plans filed herewith.
M00683925-B5
12/03/2025
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
CHUNG CHING JEN
12/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHUNG CHING JEN
12/03/2025
Special inspection requirement — Protection of exposed foundation insulation
CHUNG CHING JEN
12/03/2025
Special inspection requirement — Fenestration areas
PATRICK ORRICO
11/19/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/19/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
11/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/15/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/13/2025
Signed off — Alteration
M00962479-I1
11/12/2025
Signed off — Alteration
Installation of a temporary suppor. scaffold, heavy-duty sidewalk shed, roof, overhead, window protection, const. fence per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and occupancy with this application
M00979574-I1
11/12/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/17/2025
Signed off — New Building
Plumbing work as shown on plans filed herewith.
M00683925-S4
09/18/2025
Signed off — New Building
Plumbing work as shown on plans filed herewith.
M00683925-S1
09/18/2025
Signed off — Alteration
INSTALLATION OF A TEMPORARY SUPPORTED SCAFFOLD PER PLANS SUBMITTED. WORK SHALL COMPLY WITH 2022 BUILDING COPES, CHAPTER 33. NO CHANGE IN USE, EGRESS AND OCCUPANCY WITH THIS APPLICATION.
M01210383-I1
09/15/2025
Signed off — Alteration
M01248772-I1
09/11/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY DUAL PERSONNEL/MATERIAL HOISTS AS PER PLANS SUBMITTED. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00966541-I1
09/09/2025
Signed off — New Building
Plumbing work as shown on plans filed herewith.
M00683925-S3
09/08/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/30/2025
Violation issued (ECB, closed)
Unknown
08/28/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/28/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/19/2025
Permit issued — Plumbing
M00683925-Z1-PL
08/13/2025
Filed — New Building
Plumbing work as shown on plans filed herewith.
M00683925-B4
07/31/2025
Permit issued — General Construction
M00683925-I1-GC
07/24/2025
Filed — New Building
Plumbing work as shown on plans filed herewith.
M00683925-B3
07/22/2025
Permit issued — General Construction
M01237475-I1-GC
Latest 60 of 236 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ALBA SERVICES607/08/2026
KAHEN PROPERTIES11307/08/2026
LAKHI GENERAL CONTRACTOR, INC407/08/2026
1026 THIRD1104/09/2026
PLATINUM SERVICES NY504/09/2026
THIRD NORTH HOLDINGS503/22/2026
CARBEN CONSTRUCTION403/22/2026
THIRD NORTH LLC103/22/2026
SUNBURGER103/21/2026
1026 3RD AVENUE103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/12/2022$9.8M—— → —— not available
09/09/2021$6.2M—1026 THIRD, LLC → PORTFOLIO4 LLC— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WILLIAM VITACCO ASSOCIATES6003/21/2026
Rigid Structural Design, LLC903/21/2026
ECC403/21/2026
GREEN STUDIO203/21/2026
DVA Advisors503/21/2026
KD DESIGNS103/21/2026
HOWARD I SHAPIRO ASSOCIATES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CARBEN CONSTRUCTION INCGeneral Contractor1007/08/2026
THIRD NORTH GC LLCGeneral Contractor1007/08/2026
DHS FRACO LLCGeneral Contractor1007/08/2026
POWER SURGE ELECTRIC INC 004009General Contractor703/22/2026
STAT FIRE SPRINKLER NYC CFire Protection607/08/2026
FORWARD MECHANICAL CORPPlumbing407/08/2026
PLATINUM SERVICES NY LLCGeneral Contractor204/09/2026
ALBA SERVICES INCGeneral Contractor204/09/2026
TMS PLBG & HEATING CORPPlumbing107/08/2026
DYNAMIC HOISTING SCAFF INGeneral Contractor104/09/2026
GERALD J CALIENDO R AGeneral Contractor103/22/2026
LAKHI GENERAL CONTRACTORGeneral Contractor107/08/2026
POWER SURGE ELECTRIC, INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MACIA INSPECTION & TESTIN4022804/22/2026
WSP USA CORP1848506/06/2025
GEODESIGN, INC., P.C.627204/25/2023
LAWP ARCHITECTURE3782101/28/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offFORWARD HEATING CORP08/19/2025
DOB NOWGeneral ConstructionPermit IssuedTHIRD NORTH GC LLC07/31/2025
DOB NOWGeneral ConstructionSigned-offTHIRD NORTH GC LLC07/22/2025
DOB NOWSupported ScaffoldSigned-offDYNAMIC HOISTING SCAFF IN07/03/2025
DOB NOWSidewalk ShedSigned-offDHS FRACO06/05/2025
DOB NOWSupported ScaffoldSigned-offLAKHI GENERAL CONTRACTOR04/25/2025
DOB NOWSprinklersSigned-offSTAT FIRE SPRINKLER NYC C04/02/2025
DOB NOWStandpipeSigned-offSTAT FIRE SPRINKLER NYC C03/04/2025
DOB NOWStandpipeSigned-offSTAT FIRE SPRINKLER NYC C03/04/2025
DOB NOWGeneral ConstructionPermit IssuedTHIRD NORTH GC LLC02/18/2025
DOB NOWMechanical SystemsSigned-offTHIRD NORTH GC LLC02/05/2025
DOB NOWProtection and Mechanical MethodsSigned-offDHS FRACO01/15/2025
DOB NOWSidewalk ShedSigned-offDHS FRACO11/27/2024
DOB NOWConstruction FenceSigned-offDHS FRACO11/27/2024
DOB NOWSidewalk ShedSigned-offDHS FRACO11/27/2024
DOB NOWPlumbingSigned-offFORWARD HEATING CORP07/25/2024
DOB NOWProtection and Mechanical MethodsSigned-offCARBEN CONSTRUCTION06/07/2024
DOB NOWStructuralSigned-offTHIRD NORTH GC LLC05/24/2024
DOB NOWProtection and Mechanical MethodsSigned-offCARBEN CONSTRUCTION05/15/2024
DOB NOWConstruction FenceSigned-offTHIRD NORTH GC LLC05/09/2024
DOB NOWGeneral ConstructionPermit IssuedTHIRD NORTH GC LLC04/26/2024
DOB NOWProtection and Mechanical MethodsSigned-offCARBEN CONSTRUCTION03/13/2024
DOB NOWMechanical SystemsSigned-offTHIRD NORTH GC LLC03/07/2024
DOB NOWSupport of ExcavationSigned-offCARBEN CONSTRUCTION02/15/2024
DOB NOWProtection and Mechanical MethodsSigned-offDHS FRACO01/24/2024
DOB NOWPlumbingSigned-offFORWARD HEATING CORP01/12/2024
DOB NOWStructuralSigned-offCARBEN CONSTRUCTION12/26/2023
DOB NOWSidewalk ShedSigned-offDHS FRACO12/22/2023
DOB NOWSupported ScaffoldSigned-offDHS FRACO12/22/2023
DOB NOWConstruction FenceSigned-offDHS FRACO12/22/2023
DOB NOWStandpipeSigned-offSTAT FIRE SPRINKLER NYC C09/20/2023
DOB NOWStandpipeSigned-offSTAT FIRE SPRINKLER NYC C09/08/2023
DOB NOWSprinklersSigned-offSTAT FIRE SPRINKLER NYC C09/08/2023
DOB NOWPlumbingSigned-offFORWARD HEATING CORP08/22/2023
DOB NOWConstruction FenceSigned-offCARBEN CONSTRUCTION07/19/2023
DOB NOWFoundationSigned-offCARBEN CONSTRUCTION06/28/2023
DOB NOWSupport of ExcavationSigned-offCARBEN CONSTRUCTION06/27/2023
DOB NOWFoundationSigned-offCARBEN CONSTRUCTION06/27/2023
DOB NOWFoundationSigned-offCARBEN CONSTRUCTION06/21/2023
DOB NOWSidewalk ShedSigned-offPLATINUM SERVICES NY LLC01/04/2023
+ 5 more permits on file
▾Field Inspections (DOB CAP) — 20
DateTypeResultReport
07/16/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/19/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/19/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
11/19/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/15/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/12/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/08/2025Pass-Final CND-Occupancy InspectionPassView ↗
08/28/2025Pass-Final CND-Occupancy InspectionPassView ↗
08/28/2025Pass-Final General Construction Non-Directive 14PassView ↗
06/23/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/11/2025Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
08/07/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
03/18/2024Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
03/18/2024Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
02/01/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/23/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/22/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/18/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/08/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/22/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
04/27/2026Fenestration areasPATRICK ORRICOenergy_progress
04/27/2026Protection of exposed foundation insulationCHUNG CHING JENenergy_progress
04/27/2026Fenestration air leakagePATRICK ORRICOenergy_progress
04/27/2026Insulation placement and R valuesCHUNG CHING JENenergy_progress
04/27/2026Air barrier - visual inspectionCHUNG CHING JENenergy_progress
04/27/2026Air barrier continuity plan testingCHUNG CHING JENenergy_progress
04/27/2026Fenestration and door U-factor and product ratingsPATRICK ORRICOenergy_progress
04/27/2026Fire-Resistance Rated ConstructionCHUNG CHING JENprogress
04/27/2026Energy Code Compliance InspectionsCHUNG CHING JENprogress
04/27/2026MasonryCHUNG CHING JENspecial
04/27/2026Wall Panels, Curtain Walls, and VeneersCHUNG CHING JENspecial
04/27/2026Fire-Resistant Penetrations and JointsCHUNG CHING JENspecial
04/27/2026VestibulesCHUNG CHING JENenergy_progress
04/22/2026Energy Code Compliance InspectionsCHUNG CHING JENprogress
04/22/2026Fenestration and door U-factor and product ratingsPATRICK ORRICOenergy_progress
04/22/2026Insulation placement and R valuesCHUNG CHING JENenergy_progress
04/22/2026Fenestration areasPATRICK ORRICOenergy_progress
04/22/2026Air barrier continuity plan testingCHUNG CHING JENenergy_progress
04/22/2026VestibulesCHUNG CHING JENenergy_progress
04/22/2026Fire-Resistance Rated ConstructionCHUNG CHING JENprogress
04/22/2026Protection of exposed foundation insulationCHUNG CHING JENenergy_progress
04/22/2026Wall Panels, Curtain Walls, and VeneersCHUNG CHING JENspecial
04/22/2026MasonryCHUNG CHING JENspecial
04/22/2026Fire-Resistant Penetrations and JointsCHUNG CHING JENspecial
04/22/2026Air barrier - visual inspectionCHUNG CHING JENenergy_progress
Latest 25 of 150.
▾Documents — 396 on file (BIS + DOB NOW)
▸Plans & Drawings51
▸DOB NOWPlans/Sketch50
09/01/2026M08040234-I1Request digital key ↗
09/01/2026M08041133-I1Request digital key ↗
09/01/2026M00804564-I1Request digital key ↗
Showing 3 of 50 on file for this type
▸DOB NOWPlans/Sketch - Plumbing1
09/04/2026M00461025-I1Request digital key ↗
▸Applications & Permits18
▸BISPLAN / WORK APPROVAL APPLICATION10
08/29/2025141008406Open ↗
08/15/2025141024521Open ↗
08/14/2025141024521Open ↗
Showing 3 of 10 on file for this type
▸BISWORK PERMIT APPLICATION6
01/28/2021140992781Open ↗
05/26/2010120287206Open ↗
03/31/2010120287215Open ↗
Showing 3 of 6 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation2
08/18/2025141024521Open ↗
08/14/2025141024521Open ↗
▸Zoning, Tax Lot & Property Records80
▸DOB NOWRestrictive Declaration/Easement 134
08/17/2026M00683925-A7Open ↗
08/17/2026M00683925-A5Open ↗
08/17/2026M00683925-A4Open ↗
Showing 3 of 34 on file for this type
▸DOB NOWRestrictive Declaration/Easement 234
08/17/2026M00683925-A5Open ↗
08/17/2026M00683925-A4Open ↗
08/17/2026M00683925-P5Open ↗
Showing 3 of 34 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram6
08/17/2026M00683925-B6Open ↗
08/17/2026M00683925-A7Open ↗
Showing 2 of 6 on file for this type
▸DOB NOWZoning Exhibit form (1-5)6
08/17/2026M00683925-A1Open ↗
08/17/2026M00683925-B6Open ↗
08/17/2026M00683925-A7Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications159
▸DOB NOWSpecial Inspector Seal & Signature53
09/01/2026M00683925-P9Open ↗
09/01/2026M00683925-A6Open ↗
09/01/2026M00683925-A8Open ↗
Showing 3 of 53 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature48
09/04/2026M00461025-I1Open ↗
09/01/2026M00801072-I1Open ↗
09/01/2026M00804564-I1Open ↗
Showing 3 of 48 on file for this type
▸DOB NOWProgress Inspector Seal & Signature46
09/02/2026M08040234-I1Open ↗
09/01/2026M00683925-P9Open ↗
09/01/2026M00683925-A8Open ↗
Showing 3 of 46 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
08/14/2025141024521Open ↗
04/20/2022141008406Open ↗
01/08/2021140992781Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY-CERTIFICATION3
06/07/2010120332434Open ↗
03/10/2010120287215Open ↗
03/10/2010120287206Open ↗
▸BISAPPLICANT OWNER SIGNATURE2
08/05/2025141024521Open ↗
04/20/2022141008406Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
01/08/2021140992781Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
01/08/2021140992781Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
03/10/2010120287215Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
03/10/2010120287215Open ↗
▸Trade Schedules & Equipment14
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)5
08/17/2026M00683925-A1Open ↗
08/17/2026M00683925-A7Open ↗
Showing 2 of 5 on file for this type
▸BISSELF-CERT PLUMBING NOTICE4
07/02/2010120287215Open ↗
05/27/2010120287215Open ↗
05/14/2010120287215Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING4
06/07/2010120332434Open ↗
05/15/2010120287215Open ↗
03/10/2010120287215Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWStandpipe Alarms Drawings1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Safety & Tenant Protection10
▸DOB NOWStreet Tree Checklist6
08/17/2026M00683925-A1Open ↗
08/17/2026M00683925-B6Open ↗
08/17/2026M00683925-A7Open ↗
Showing 3 of 6 on file for this type
▸BISBPP: STREET TREES SITE PLAN2
08/05/2025141024521Open ↗
04/20/2022141008406Open ↗
▸BISTPP1: TENANT PROTECTION PLAN1
04/23/2021140992781Open ↗
▸BISSTREET TREE CHECKLIST1
08/05/2025141024521Open ↗
▸Environmental & Asbestos8
▸BISASBESTOS-CERTIFICATION (DEP ACP5)3
06/07/2010120332434Open ↗
03/10/2010120287215Open ↗
01/08/2021140992781Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/04/2026M00461025-I1Open ↗
Showing 1 of 3 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
06/07/2010120332434Open ↗
03/10/2010120287206Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
11/22/2021140992781Open ↗
01/21/2021140992781Open ↗
01/08/2021140992781Open ↗
▸DOB NOWPreliminary Commissioning Report Certification2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
01/08/2021140992781Open ↗
▸BISNYCECC ANALYSIS1
01/08/2021140992781Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY3
11/03/2021140992781Open ↗
01/21/2021140992781Open ↗
01/08/2021140992781Open ↗
▸DOB NOWSOIL REPORT2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWTR5 Test Report1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs3
▸BISADMINISTRATIVE OBJECTIONS3
06/07/2010120332434Open ↗
03/10/2010120287215Open ↗
03/10/2010120287206Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
01/08/2021140992781Open ↗
06/07/2010120332434Open ↗
03/10/2010120287215Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms7
▸BISEFILING JOB APPLICATION COVER SHEET4
08/05/2025141024521Open ↗
04/20/2022141008406Open ↗
01/08/2021140992781Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET2
03/10/2010120287215Open ↗
03/10/2010120287206Open ↗
▸BISADDITIONAL INFORMATION1
05/19/2010120287215Open ↗
▸Other Documents28
▸DOB NOWSite Survey: Initial6
08/17/2026M00683925-I1Open ↗
08/17/2026M00683925-B6Open ↗
08/17/2026M00683925-A7Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone6
08/17/2026M00683925-B6Open ↗
08/17/2026M00683925-A7Open ↗
08/17/2026M00683925-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProperty Ownership Certification6
08/17/2026M00683925-B6Open ↗
Showing 1 of 6 on file for this type
▸DOB NOWStructural Peer Review Report5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION1
04/20/2022141008406Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
08/14/2025141024521Open ↗
▸DOB NOWAdjoining Owners Notification1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWEvaluation of Adjacent Building Report (BC 1817.3)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWProject Specific General Liability (PGL1)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type