ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING, I OBSERVED ACTIVE DEMOLITION SITE WITH 6 WORKERS ON SITE, 2 WORKERS ON SUPPORTED PIPE SCAFFOLD WITH NO GUARDRAILS, NO SCREW JACKS NO BASEPLATES AND THEY WERE$5K due
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING, I OBSERVED ACTIVE DEMOLITION SITE WITH 6 WORKERS ON SITE AND LARGE EXCAVATOR IN USED, UPON REQUEST FOR CERTIFICATION TO OPERATE IT WAS EXPIRED. FAILURE TO PRO$2K due
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING, I OBSERVED ACTIVE DEMOLITION SITE WITH 6 WORKERS ON SITE AND AT EXPOSURE #3 A FREE STANDING WALL WAS LEFT IN PLACE IN DANGER OF COLLAPSING. FAILURE TO REMOVED$5K due
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING, I OBSERVED ACTIVE DEMOLITION SITE WITH 6 WORKERS, FIRE HYDRANT AT EXPOSURE #2 WITH HOSE CONNECTED TO JOBSITE, UPON REQUEST FOR DEP PERMIT TO USED FIRE HYDRANT$2K due
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING FOR FULL DEMOLITION AND 1ST FLOOR PARTIALLY DEMO, I OBSERVED LARGE EXCAVATOR ON FOOT PRINT OF BUILDING ON TOP OF BASEMENT/CELLAR, UPON REVIEW OF THE DEPARTMENT$2K due
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING, I OBSERVED ACTIVE DEMOLITION SITE WITH 6 WORKERS ON SITE. UPON REQUEST FOR SITE SAFETY ORIENTATION AND REFRESHER NONE WAS PRESENTED OR AT JOBSITE. FAILURE TO$5K due
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING, I OBSERVED ACTIVE DEMOLITION SITE WITH 6 WORKERS ON SITE. OXYGEN AND ACETYLENE TANKS WITH HOSE WAS NOT SECURED, UPON REQUEST FOR FDNY PERMIT NONE WAS PRESENTE$5K due
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING, FULL DEMOLITION, I OBSERVED SIDEWALK SHED AND CONSTRUCTION FENCE INSTALLED AT EXPOSURE #1 AND 2, UPON REQUEST FOR DOT PERMIT TO OCCUPY AND CROSS SIDEWALK NONE$5K due
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 2 STORY BUILDING, I OBSERVED ACTIVE DEMOLITION SITE, LARGE AMOUNT OF DEMOLITION DEBRIS WITH SHEETROCK, WOOD PLANKS, INSTALLATION AND PAPERS WERE ALL PILE UP. FAILURE TO REMOVE$5K due
DOB11/26/1999V-DOB VIOLATION - ACTIVE
DOB11/26/1999V-DOB VIOLATION - ACTIVE
DOB07/10/1995V-DOB VIOLATION - ACTIVE
ECB04/24/2016FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES. NOTED : @ EXP 1, 2 & 3 BRICKS MORTAR MISSING CRACKS AT (PURING) & SOME BRICKS MISSING. REMEDY: MAIN EXTERIOR BLDG WALLNothing owed — awaiting certificate of correction
ECB03/11/2016FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES - MAINTAIN EXTERIOR BLDG WALL.NOTE:@PARAPET WALL(S) EXP #1,2,AND 3 BRICK MORTAR MISSING.CRACKS @(PURING) AND SOME BRICKS MISSING.REM:REPAIR PARAPET AND NOTENothing owed — awaiting certificate of correction