← Back
Two family brick
1027 EAST 211 STREET
BRONX · Williamsbridge-Olinville · BIN 2059247
💬 Discuss this project
1945Year Built
1Stories
B1Building Class
R4Zoning
1,932 sfGross Floor Area
2Units
2 Open Violations ▸
Two family brick · 3,035 sf lot · 0.64 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof3p · 1 filing · 17 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC209/26/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802209/26/2025
Building Lifecycle
All (26)Filed (2)Permit Issued (1)Signed Off (1)Violation (12)Special Inspection (10)
10/23/2025
Signed off — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
X01261893-I1
10/01/2025
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
10/01/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
10/01/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
10/01/2025
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
10/01/2025
Special inspection requirement — Final
Kaijin Liang
09/26/2025
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
X01261893-P1
09/22/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
09/22/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
09/22/2025
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
09/22/2025
Special inspection requirement — Final
Kaijin Liang
09/22/2025
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
08/08/2025
Permit issued — Solar
X01261893-I1-SL
07/25/2025
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
X01261893-I1
08/05/2019
Violation issued (HPD, open)
I
08/01/2019
Violation issued (HPD, closed)
B
08/01/2019
Violation issued (HPD, closed)
B
08/01/2019
Violation issued (HPD, closed)
B
08/01/2019
Violation issued (HPD, closed)
B
08/01/2019
Violation issued (HPD, closed)
B
08/01/2019
Violation issued (HPD, closed)
B
08/01/2019
Violation issued (HPD, closed)
C
07/30/2013
Violation issued (HPD, closed)
C
06/27/2013
Violation issued (HPD, open)
C
06/27/2013
Violation issued (HPD, closed)
A
06/27/2013
Violation issued (HPD, closed)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP08/08/2025
1 project · most recent 07/24/2025
FiledStatusContractorScope
07/24/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
10/01/2025Air barrier - visual inspectionKaijin Liangenergy_progress
10/01/2025Fire-Resistant Penetrations and JointsKaijin Liangspecial
10/01/2025Structural Stability – Alterations of existing buildingsKaijin Liangspecial
10/01/2025Energy Code Compliance InspectionsKaijin Liangprogress
10/01/2025FinalKaijin Liangprogress
09/22/2025Fire-Resistant Penetrations and JointsKaijin Liangspecial
09/22/2025Structural Stability – Alterations of existing buildingsKaijin Liangspecial
09/22/2025Energy Code Compliance InspectionsKaijin Liangprogress
09/22/2025FinalKaijin Liangprogress
09/22/2025Air barrier - visual inspectionKaijin Liangenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/18/2026X01261893-I1Request digital key ↗
08/18/2026X01261893-P1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
09/02/2026X01261893-I1Open ↗
09/02/2026X01261893-I1Open ↗
09/02/2026X01261893-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/02/2026X01261893-I1Open ↗
09/02/2026X01261893-I1Open ↗
08/29/2026X01261893-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/18/2026X01261893-I1Open ↗
08/18/2026X01261893-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/18/2026X01261893-I1Open ↗
08/18/2026X01261893-P1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01261893-I1Open ↗