← Back
Predominantly retail with other uses
103-11 101 AVENUE
QUEENS · BIN 4197731
💬 Discuss this project
1910Year Built
2Stories
K4Building Class
R6BZoning
2,840 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Predominantly retail with other uses · Owner of record: ARJ CAPITAL LLC · 1,703 sf lot · 1.67 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/17/2023$955K—JASON K, INC. → ARJ CAPITAL LLC$336/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARNOLD MONTAG ARCHITECT AM/PM DESI806/25/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MVP CONTRACTORS CORPGeneral Contractor303/21/2026
KISHAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ARNOLD MONTAG ARCHITECT,4599606/25/2024
Building Lifecycle
All (96)Filed (8)Permit Issued (2)Signed Off (2)Violation (5)Inspection (5)Objection (44)Special Inspection (30)
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/17/2024
Signed off — Alteration
interior renovation to cellar,1st floor & 2nd floor of mixed use building with cellar.
Q00898744-I1
07/16/2024
Signed off — Alteration
interior renovation to cellar,1st floor & 2nd floor of mixed use building with cellar.
Q00898744-S1
07/15/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
07/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Arnold Montag
07/05/2024
Special inspection requirement — Fire-Resistance Rated Construction
Arnold Montag
07/05/2024
Special inspection requirement — Energy Code Compliance Inspections
Arnold Montag
07/05/2024
Special inspection requirement — Concrete - Cast-In-Place
Arnold Montag
07/05/2024
Special inspection requirement — Lighting controls
Arnold Montag
07/05/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Arnold Montag
07/05/2024
Special inspection requirement — Fenestration areas
Arnold Montag
07/05/2024
Special inspection requirement — Interior lighting power
Arnold Montag
07/05/2024
Special inspection requirement — Fenestration air leakage
Arnold Montag
07/05/2024
Special inspection requirement — Air barrier - visual inspection
Arnold Montag
06/25/2024
Filed — Alteration
interior renovation to cellar,1st floor & 2nd floor of mixed use building with cellar.
Q00898744-P4
06/20/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Arnold Montag
06/20/2024
Special inspection requirement — Energy Code Compliance Inspections
Arnold Montag
06/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Arnold Montag
06/13/2024
Filed — Alteration
interior renovation to cellar,1st floor & 2nd floor of mixed use building with cellar.
Q00898744-P3
06/06/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Arnold Montag
06/06/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Arnold Montag
06/06/2024
Special inspection requirement — Energy Code Compliance Inspections
Arnold Montag
05/23/2024
Filed — Alteration
interior renovation to cellar,1st floor & 2nd floor of mixed use building with cellar.
Q00898744-P2
05/13/2024
Special inspection requirement — Energy Code Compliance Inspections
Arnold Montag
05/13/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Arnold Montag
05/13/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Arnold Montag
03/22/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/07/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/05/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/08/2024
Filed — Alteration
interior renovation to cellar,1st floor & 2nd floor of mixed use building with cellar.
Q00898744-P1
02/06/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Arnold Montag
02/06/2024
Special inspection requirement — Energy Code Compliance Inspections
Arnold Montag
02/06/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Arnold Montag
02/05/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/29/2024
Permit issued — Plumbing
Q00898744-S1-PL
01/04/2024
Objection resolved — Addressed
01/03/2024
Objection resolved — Addressed
01/02/2024
Special inspection requirement — Metering
01/02/2024
Special inspection requirement — Lighting in dwelling units
01/02/2024
Special inspection requirement — Maintenance information
01/02/2024
Special inspection requirement — Fenestration air leakage
01/02/2024
Special inspection requirement — Fenestration areas
01/02/2024
Special inspection requirement — Concrete - Cast-In-Place
01/02/2024
Special inspection requirement — Air barrier - visual inspection
01/02/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
12/21/2023
Objection resolved — Addressed
12/21/2023
Objection resolved — Addressed
12/21/2023
Objection resolved — Addressed
12/21/2023
Objection resolved — Addressed
12/20/2023
Objection raised — Energy
12/20/2023
Objection raised — Structural
12/20/2023
Objection raised — Inspections
12/20/2023
Objection raised — Structural
12/20/2023
Objection raised — Structural
12/19/2023
Objection raised — Admin
12/15/2023
Permit issued — General Construction
Q00898744-I1-GC
12/12/2023
Filed — Alteration CO
convert cellar into additional office space to be used in conjunction with 1st floor
Q00940369-S1
12/12/2023
Objection resolved — Addressed
12/12/2023
Objection resolved — Addressed
12/12/2023
Objection resolved — Addressed
Latest 60 of 96 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offN AND S PLUMBING INC01/29/2024
DOB NOWGeneral ConstructionSigned-offMVP CONTRACTORS CORP12/15/2023
BISOTISSUEDGWANGGAETOU DEVELOPMENT, CORP09/20/2007
1 project · most recent 01/25/2024
FiledStatusContractorScope
01/25/2024CompleteAUJLA ELECTRIC CORP—
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/15/2024Pass-Final General Construction Non-Directive 14PassView ↗
03/22/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/07/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/05/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/05/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 40
DateRequirementInspectorRole
07/05/2024Fire-Resistant Penetrations and JointsArnold Montagspecial
07/05/2024Fire-Resistance Rated ConstructionArnold Montagprogress
07/05/2024Energy Code Compliance InspectionsArnold Montagprogress
07/05/2024Concrete - Cast-In-PlaceArnold Montagspecial
07/05/2024Lighting controlsArnold Montagenergy_progress
07/05/2024Fenestration and door U-factor and product ratingsArnold Montagenergy_progress
07/05/2024Fenestration areasArnold Montagenergy_progress
07/05/2024Interior lighting powerArnold Montagenergy_progress
07/05/2024Fenestration air leakageArnold Montagenergy_progress
07/05/2024Air barrier - visual inspectionArnold Montagenergy_progress
06/20/2024HVAC-R and service water piping design and insulationArnold Montagenergy_progress
06/20/2024Energy Code Compliance InspectionsArnold Montagprogress
06/20/2024Fire-Resistant Penetrations and JointsArnold Montagspecial
06/06/2024HVAC-R and service water piping design and insulationArnold Montagenergy_progress
06/06/2024Fire-Resistant Penetrations and JointsArnold Montagspecial
06/06/2024Energy Code Compliance InspectionsArnold Montagprogress
05/13/2024Energy Code Compliance InspectionsArnold Montagprogress
05/13/2024Fire-Resistant Penetrations and JointsArnold Montagspecial
05/13/2024HVAC-R and service water piping design and insulationArnold Montagenergy_progress
02/06/2024HVAC-R and service water piping design and insulationArnold Montagenergy_progress
02/06/2024Energy Code Compliance InspectionsArnold Montagprogress
02/06/2024Fire-Resistant Penetrations and JointsArnold Montagspecial
01/02/2024Metering—energy_progress
01/02/2024Lighting in dwelling units—energy_progress
01/02/2024Maintenance information—energy_progress
Latest 25 of 40.
▾Documents — 53 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/24/2026Q00940369-I1Request digital key ↗
08/24/2026Q00940369-S1Request digital key ↗
08/22/2026Q00898744-S1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits1
▸BISWORK PERMIT APPLICATION1
09/20/2007410004418Open ↗
▸Seals & Professional Certifications30
▸DOB NOWProgress Inspector Seal & Signature11
08/29/2026Q00898744-P2Open ↗
08/29/2026Q00898744-P2Open ↗
08/28/2026Q00898744-P1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/13/2026Q00898744-I1Open ↗
08/13/2026Q00898744-S1Open ↗
08/13/2026Q00898744-P2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
08/29/2026Q00898744-P2Open ↗
08/28/2026Q00898744-P1Open ↗
08/28/2026Q00940369-S1Open ↗
Showing 3 of 7 on file for this type
▸BISPC FULL REPORT1
09/19/2007410004418Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/19/2007410004418Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
09/19/2007410004418Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/19/2007410004418Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q00940369-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/13/2026Q00898744-P3Open ↗
08/13/2026Q00898744-S1Open ↗
08/13/2026Q00898744-P4Open ↗
Showing 3 of 8 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
09/19/2007410004418Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
07/31/2008410004418Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
09/19/2007410004418Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/20/2007410004418Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/13/2026Q00940369-I1Open ↗