← Back
Walk-up apt, over six families with stores
103 ST MARKS PLACE
MANHATTAN · BIN 1005889
💬 Discuss this project
1920Year Built
5Stories
C7Building Class
R8BZoning
13,405 sfGross Floor Area
23Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Walk-up apt, over six families with stores · Owner of record: VOYAGE ASSETS LLC · 3,522 sf lot · 3.81 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ALLIED REALTY DEVELOPMENT1007/08/2026
ALLIED REALTY LLC903/22/2026
VOYAGE ASSETS LLC103/22/2026
ADRIA REALTY INVESTMENT ASSOC703/21/2026
ARIA REALTY INVESTMENT ASSOCIATE403/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/19/2016$11.5M—— → —$860/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ATELIER NY ARCHITECTURE403/10/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ATELIER NEW YORK ARCHITECTURE403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BO7 CONSTRUCTION CORPGeneral Contractor707/08/2026
WATSON'S PLBG, HTG, & BDGPlumbing207/08/2026
BABICH, ETTOREElectrical103/21/2026
CADOGAN, JOELElectrical103/21/2026
CLIFFORD, NICHOLASElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ATELIER NY ARCHITECTURE2438203/09/2022
GREYSTONE ENGINEERING CON2973103/09/2022
Building Lifecycle
All (53)Filed (4)Permit Issued (5)Signed Off (4)Violation (18)Inspection (6)Special Inspection (16)
07/20/2022
Signed off — Alteration
M00651833-I1
06/30/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/16/2022
Signed off — Alteration
INTERIOR RENOVATION OF APARTMENTS 5A & 5B AND INSTALLATION OF NEW SKYLIGHT. PARTITION CHANGES AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M00692720-I1
05/11/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/09/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/08/2022
Permit issued — Structural
M00692720-I1-GC-CX
03/17/2022
Permit issued — Plumbing
M00651833-I1-PL
03/16/2022
Permit issued — Structural
M00692720-I1-GC-CX
03/10/2022
Filed — Alteration
M00651833-I1
03/09/2022
Filed — Alteration
INTERIOR RENOVATION OF APARTMENTS 5A & 5B AND INSTALLATION OF NEW SKYLIGHT. PARTITION CHANGES AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M00692720-I1
03/07/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Anatole Plotkin
03/07/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
TIMOTHY TWEEDY
03/07/2022
Special inspection requirement — Energy Code Compliance Inspections
Anatole Plotkin
03/07/2022
Special inspection requirement — Fire-Resistance Rated Construction
Anatole Plotkin
03/07/2022
Special inspection requirement — Structural Wood Frame
TIMOTHY TWEEDY
03/07/2022
Special inspection requirement — Air barrier - visual inspection
Anatole Plotkin
03/07/2022
Special inspection requirement — Fenestration air leakage
Anatole Plotkin
03/07/2022
Special inspection requirement — Fenestration areas
Anatole Plotkin
03/07/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Anatole Plotkin
03/07/2022
Special inspection requirement — Lighting in dwelling units
Anatole Plotkin
03/06/2022
Special inspection requirement — Final
Anatole Plotkin
02/16/2022
Violation issued (HPD, closed)
A
11/11/2021
Signed off — Alteration
INTERIOR RENOVATION TO CONVERT APARTMENTS 4C & 4D INTO FL & FR. PARTITION CHANGES TO NON-LOAD-BEARING WALLS AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M00500412-I1
10/12/2021
Signed off — Alteration
INTERIOR RENOVATION OF APARTMENTS 4C & 4D INTO FL & FR. PLUMBING WORK AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M00517415-I1
09/08/2021
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/20/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/16/2021
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/01/2021
Permit issued — Plumbing
M00517415-I1-PL
05/13/2021
Filed — Alteration
INTERIOR RENOVATION OF APARTMENTS 4C & 4D INTO FL & FR. PLUMBING WORK AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M00517415-I1
05/13/2021
Permit issued — General Construction
M00500412-I1-GC
05/06/2021
Filed — Alteration
INTERIOR RENOVATION TO CONVERT APARTMENTS 4C & 4D INTO FL & FR. PARTITION CHANGES TO NON-LOAD-BEARING WALLS AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M00500412-I1
05/06/2021
Special inspection requirement — Lighting in dwelling units
Anatole Plotkin
05/06/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Anatole Plotkin
05/06/2021
Special inspection requirement — Energy Code Compliance Inspections
Anatole Plotkin
05/06/2021
Special inspection requirement — Fire-Resistance Rated Construction
Anatole Plotkin
04/08/2021
Special inspection requirement — Final
Anatole Plotkin
04/01/2021
Violation issued (HPD, closed)
A
01/22/2020
Violation issued (HPD, closed)
B
01/22/2020
Violation issued (HPD, closed)
C
02/21/2019
Violation issued (HPD, closed)
B
02/15/2018
Violation issued (HPD, closed)
B
02/15/2018
Violation issued (HPD, closed)
B
10/28/2017
Violation issued (HPD, closed)
B
10/28/2017
Violation issued (HPD, closed)
B
10/28/2017
Violation issued (HPD, closed)
B
10/28/2017
Violation issued (HPD, closed)
B
10/19/2017
Violation issued (HPD, closed)
C
10/19/2017
Violation issued (HPD, closed)
A
10/19/2017
Violation issued (HPD, closed)
A
10/19/2017
Violation issued (HPD, closed)
A
10/19/2017
Violation issued (HPD, closed)
A
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offBO7 CONSTRUCTION CORP04/08/2022
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG03/17/2022
DOB NOWStructuralSigned-offBO7 CONSTRUCTION CORP03/16/2022
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG06/01/2021
DOB NOWGeneral ConstructionSigned-offBO7 CONSTRUCTION CORP05/13/2021
BISOTISSUEDM.C.P RESTORATION CORP06/19/2017
BISPLISSUEDARIANA CONTRACTING INC01/10/2017
BISMHISSUEDCENTRAL BUILDERS DEVELOPMENT12/08/2016
BISMHISSUEDHI TECH CONSTRUCTION & *06/04/2015
BISPLISSUEDJULIAN PLBG & HTG CORP09/17/2014
BISOTISSUEDHI TECH CONSTRUCTION & *08/22/2014
BISOTISSUEDHI TECH CONSTRUCTION & *07/16/2014
BISOTISSUEDJOSIP SOVULJ & JOHN LUCIC09/29/2010
BISOTISSUEDACORN FURNISHING CORP11/07/2007
BISBLISSUEDBAYRIDGE FUEL CORP05/04/2004
BISOTISSUEDADRIA REALTY INVESTMENT ASSOCIAT04/25/2002
BISOTISSUEDADRIA REALTY INVESTMENT ASSOCIAT10/17/2001
BISPLRE-ISSUEDWILLIAM C. GERAKARIS P&H02/16/2001
BISMHISSUEDADRIA REALTY INVESTMENT ASSOCIAT02/16/2001
BISPLISSUEDWILLIAM C. GERAKARIS P&H01/06/1999
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
06/30/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/11/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/09/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/08/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/20/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/16/2021Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
03/07/2022Fire-Resistant Penetrations and JointsAnatole Plotkinspecial
03/07/2022Structural Stability – Alterations of existing buildingsTIMOTHY TWEEDYspecial
03/07/2022Energy Code Compliance InspectionsAnatole Plotkinprogress
03/07/2022Fire-Resistance Rated ConstructionAnatole Plotkinprogress
03/07/2022Structural Wood FrameTIMOTHY TWEEDYprogress
03/07/2022Air barrier - visual inspectionAnatole Plotkinenergy_progress
03/07/2022Fenestration air leakageAnatole Plotkinenergy_progress
03/07/2022Fenestration areasAnatole Plotkinenergy_progress
03/07/2022Fenestration and door U-factor and product ratingsAnatole Plotkinenergy_progress
03/07/2022Lighting in dwelling unitsAnatole Plotkinenergy_progress
03/06/2022FinalAnatole Plotkinprogress
05/06/2021Lighting in dwelling unitsAnatole Plotkinenergy_progress
05/06/2021Fire-Resistant Penetrations and JointsAnatole Plotkinspecial
05/06/2021Energy Code Compliance InspectionsAnatole Plotkinprogress
05/06/2021Fire-Resistance Rated ConstructionAnatole Plotkinprogress
04/08/2021FinalAnatole Plotkinprogress
▾Documents — 118 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
09/03/2026M00500412-I1Request digital key ↗
09/03/2026M00517415-I1Request digital key ↗
09/02/2026M00692720-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits21
▸BISPLAN / WORK APPROVAL APPLICATION12
06/21/2017140574778Open ↗
06/21/2017140574778Open ↗
06/02/2017140651337Open ↗
Showing 3 of 12 on file for this type
▸BISWORK PERMIT APPLICATION9
06/19/2017140651337Open ↗
01/10/2017140574778Open ↗
12/08/2016140574778Open ↗
Showing 3 of 9 on file for this type
▸Seals & Professional Certifications37
▸DOB NOWProgress Inspector Seal & Signature8
09/29/2026M00692720-I1Open ↗
09/29/2026M00692720-I1Open ↗
09/29/2026M00692720-I1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
08/07/2015140219788Open ↗
09/07/2010120462551Open ↗
06/19/2008110009151Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM4
09/07/2010120462551Open ↗
09/07/2010120462551Open ↗
09/07/2010120462551Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/02/2026M00692720-I1Open ↗
09/02/2026M00651833-I1Open ↗
08/13/2026M00517415-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
09/07/2010120462551Open ↗
12/03/2007110009151Open ↗
11/02/2007110009151Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
06/02/2017140651337Open ↗
11/14/2016140574778Open ↗
07/15/2014140219788Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
06/02/2017140651337Open ↗
11/14/2016140574778Open ↗
07/15/2014140219788Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
06/02/2017140651337Open ↗
11/14/2016140574778Open ↗
07/15/2014140219788Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/29/2026M00692720-I1Open ↗
09/29/2026M00692720-I1Open ↗
08/25/2026M00500412-I1Open ↗
▸BISPC FULL REPORT1
11/02/2007110009151Open ↗
▸Trade Schedules & Equipment12
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE4
06/21/2017140574778Open ↗
01/23/2017140574778Open ↗
07/07/2015140219788Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING3
06/02/2017140651337Open ↗
11/14/2016140574778Open ↗
07/15/2014140219788Open ↗
▸BISEQUIPMENT USE PERMITS2
08/05/2015140219788Open ↗
08/04/2015140219788Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
07/17/2015140219788Open ↗
03/10/2015140219788Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
08/04/2015140219788Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/02/2026M00692720-I1Open ↗
09/02/2026M00651833-I1Open ↗
08/13/2026M00517415-I1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
06/02/2017140651337Open ↗
11/14/2016140574778Open ↗
07/15/2014140219788Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
09/07/2010120462551Open ↗
▸Energy Compliance11
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS3
06/02/2017140651337Open ↗
11/14/2016140574778Open ↗
07/15/2014140219788Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
06/02/2017140651337Open ↗
11/14/2016140574778Open ↗
07/15/2014140219788Open ↗
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026M00500412-I1Open ↗
09/02/2026M00692720-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/07/2015140219788Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
08/05/2015140219788Open ↗
▸BISNYCECC ANALYSIS1
07/15/2014140219788Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
06/02/2017140651337Open ↗
11/14/2016140574778Open ↗
07/15/2014140219788Open ↗
▸Approvals, Objections & Sign-offs6
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
08/07/2015140219788Open ↗
11/19/2010120462551Open ↗
06/19/2008110009151Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
09/07/2010120462551Open ↗
11/02/2007110009151Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
06/21/2017140574778Open ↗
▸Cost, Insurance & Ownership8
▸BISCOST AFFIDAVIT8
06/02/2017140651337Open ↗
11/14/2016140574778Open ↗
08/07/2015140219788Open ↗
Showing 3 of 8 on file for this type
▸Filing & Intake Forms8
▸BISADDITIONAL INFORMATION4
05/22/2017140574778Open ↗
01/26/2017140574778Open ↗
03/06/2015102480209Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
06/02/2017140651337Open ↗
11/14/2016140574778Open ↗
07/15/2014140219788Open ↗
▸BISEFILING COVER SHEET1
09/07/2010120462551Open ↗