← Back
Three families
1035 KELLY STREET
BRONX · Longwood · BIN 2099753
💬 Discuss this project
1993Year Built
2Stories
C0Building Class
R7-1Zoning
2,520 sfGross Floor Area
3Units
Rent Stabilized0 Open Violations
Three families · 2,100 sf lot · 1.2 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalGeneral
Roof6p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DELUXE CONSTRUCTION CORP203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC201/08/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CENTURION SOLAR ENERGYGeneral Contractor303/21/2026
BERGER QUALITY ELEC'L CONElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854201/08/2025
Building Lifecycle
All (17)Filed (2)Permit Issued (1)Signed Off (1)Violation (8)Special Inspection (5)
06/05/2025
Violation issued (HPD, closed)
A
02/25/2025
Signed off — Alteration
X01034130-I1
02/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
02/13/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
02/13/2025
Special inspection requirement — Final
TOM PETERSEN
02/13/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
02/13/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
01/08/2025
Filed — Alteration
X01034130-P1
04/29/2024
Permit issued — Solar
X01034130-I1-SL
04/11/2024
Filed — Alteration
X01034130-I1
04/02/2024
Violation issued (HPD, closed)
A
03/17/2023
Violation issued (HPD, closed)
A
11/03/2022
Violation issued (HPD, closed)
I
02/17/2022
Violation issued (HPD, closed)
A
04/02/2021
Violation issued (HPD, closed)
A
07/19/2004
Violation issued (ECB, closed)
Construction
07/19/2004
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offCENTURION SOLAR ENERGY04/29/2024
BISPLISSUEDPRIME PIPING & HEATING IN04/15/2009
BIS—ISSUEDN/A04/01/2009
BISPLISSUEDPRIME PIPING & HEATING IN08/01/2007
BIS—ISSUEDPEA CORP10/23/2006
BIS—ISSUEDDELUXE CONSTRUCTION CORP. OF NY11/09/1993
BIS—ISSUEDDELUXE CONSTRUCTION CORP. OF NY10/27/1992
BISPLISSUEDDUO PLUMBING & HTG CORP.03/19/1992
BIS—ISSUEDDELUXE CONSTRUCTION CORP. OF NY02/04/1992
1 project · most recent 04/10/2024
FiledStatusContractorScope
04/10/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
02/13/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
02/13/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
02/13/2025FinalTOM PETERSENprogress
02/13/2025Energy Code Compliance InspectionsTOM PETERSENprogress
02/13/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026X01034130-I1Request digital key ↗
08/20/2026X01034130-P1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature3
09/14/2026X01034130-I1Open ↗
09/14/2026X01034130-I1Open ↗
09/14/2026X01034130-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026X01034130-P1Open ↗
08/20/2026X01034130-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/14/2026X01034130-I1Open ↗
09/14/2026X01034130-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01034130-I1Open ↗