← Back
Two stories - detached, small or mid-size
1037 EAST 225 STREET
BRONX · Williamsbridge-Olinville · BIN 2064952
💬 Discuss this project
1935Year Built
2Stories
A1Building Class
R4Zoning
1,434 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,725 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 6 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC105/19/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNCO CAPITAL LLCGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854105/19/2025
Building Lifecycle
All (11)Filed (1)Permit Issued (1)Objection (4)Special Inspection (5)
06/25/2025
Permit issued — Solar
X01227786-I1-SL
06/19/2025
Objection resolved — Addressed
06/10/2025
Objection resolved — Addressed
06/04/2025
Objection raised — Fire_Protection
06/04/2025
Objection raised — Electrical
05/19/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01227786-I1
05/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/19/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
05/19/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/19/2025
Special inspection requirement — Final
TOM PETERSEN
05/19/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSUNCO CAPITAL LLC06/25/2025
2 projects · most recent 07/07/2025
FiledStatusContractorScope
07/07/2025CompleteCREATIVE CABLNG & BERTRAM1 meters
05/25/2025CompleteBERGER QUALITY ELEC'L CON—
1 project · most recent 05/19/2025
FiledStatusContractorScope
05/19/2025Permit IssuedSUNCO CAPITAL LLC16 panels, 6.88 kw, 784 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/19/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/19/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
05/19/2025Energy Code Compliance InspectionsTOM PETERSENprogress
05/19/2025FinalTOM PETERSENprogress
05/19/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/19/2026X01227786-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026X01227786-I1Open ↗
08/28/2026X01227786-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/19/2026X01227786-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026X01227786-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/19/2026X01227786-I1Open ↗