← Back
Three families
104-09 101 AVENUE
QUEENS · BIN 4197773
💬 Discuss this project
1910Year Built
3Stories
C0Building Class
R6BZoning
3,300 sfGross Floor Area
3Units
Rent Stabilized2 Open Violations 0 unresolved · 2 paperwork only ▸FDNY Report ↗
Three families · 1,500 sf lot · 2.2 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/21/2021$834K—— → —$253/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MADRIAGA ENGINEERING P.C.111/01/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BERNARDO GAMBA103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EXPERTDESIGNERS,DESIGNGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
J&R DESIGN AND INSPECTION6637111/01/2021
Building Lifecycle
All (31)Filed (1)Permit Issued (1)Signed Off (1)Violation (19)Inspection (2)Objection (2)Special Inspection (5)
12/02/2024
Violation issued (HPD, closed)
I
04/15/2024
Violation issued (HPD, closed)
A
11/27/2023
Violation issued (HPD, closed)
I
03/28/2023
Violation issued (HPD, closed)
A
11/16/2022
Violation issued (HPD, closed)
I
05/18/2022
Signed off — Alteration
MINOR INTERIOR RENOVATION AT CELLAR, FIRST, SECOND AND THIRD FLOOR AS PER PLANS. CHANGE OF EXISTING FACADE MATERIAL TO BRICK VENEER AT FIRST FLOOR. NO CHANGES IN USE, EGRESS, OR OCCUPANCY.
Q00602822-I1
05/17/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
05/04/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/08/2022
Permit issued — General Construction
Q00602822-I1-GC
03/04/2022
Violation issued (HPD, closed)
A
03/04/2022
Violation issued (HPD, closed)
I
11/03/2021
Objection raised — Zoning
11/03/2021
Objection resolved — Addressed
11/01/2021
Filed — Alteration
MINOR INTERIOR RENOVATION AT CELLAR, FIRST, SECOND AND THIRD FLOOR AS PER PLANS. CHANGE OF EXISTING FACADE MATERIAL TO BRICK VENEER AT FIRST FLOOR. NO CHANGES IN USE, EGRESS, OR OCCUPANCY.
Q00602822-I1
11/01/2021
Special inspection requirement — Insulation placement and R values
Robert Truskosky
11/01/2021
Special inspection requirement — Air barrier - visual inspection
Robert Truskosky
11/01/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
Robert Truskosky
09/29/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Robert Truskosky
09/29/2021
Special inspection requirement — Interior lighting power
Robert Truskosky
04/15/2021
Violation issued (HPD, closed)
I
04/15/2021
Violation issued (HPD, closed)
A
11/01/2019
Violation issued (HPD, closed)
I
10/23/2018
Violation issued (HPD, closed)
I
12/04/2017
Violation issued (HPD, closed)
I
11/18/2016
Violation issued (HPD, closed)
I
10/15/2015
Violation issued (HPD, closed)
I
02/27/2015
Violation issued (HPD, closed)
I
12/30/2010
Violation issued (ECB, closed)
Construction
12/30/2010
Violation issued (ECB, closed)
Unknown
12/30/2010
Violation issued (ECB, open)
Construction
02/28/2007
Violation issued (ECB, open)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offEXPERTDESIGNERS,DESIGN03/08/2022
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
05/17/2022Pass-Final General Construction Non-Directive 14PassView ↗
05/04/2022Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
11/01/2021Insulation placement and R valuesRobert Truskoskyenergy_progress
11/01/2021Air barrier - visual inspectionRobert Truskoskyenergy_progress
11/01/2021Fenestration and door U-factor and product ratingsRobert Truskoskyenergy_progress
09/29/2021Structural Stability – Alterations of existing buildingsRobert Truskoskyspecial
09/29/2021Interior lighting powerRobert Truskoskyenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026Q00602822-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q00602822-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/31/2026Q00602822-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026Q00602822-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q00602822-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00602822-I1Open ↗