← Back
Two stories - detached, small or mid-size
104-22 113 STREET
QUEENS · South Ozone Park · BIN 4202539
💬 Discuss this project
1925Year Built
2Stories
A1Building Class
R4AZoning
1,216 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 2,500 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Floor 26p · 1 filing · 10 docs
Floor 14p · 1 filing · 10 docs
Filed — no permit issued4p · 1 filing · 3 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NS ENGINEERS, P.C.309/15/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HALF SQUARE603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PULATANI BUILDERS INCGeneral Contractor407/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NS ENGINEERS, P.C.1442209/15/2021
Building Lifecycle
All (12)Filed (3)Permit Issued (2)Violation (1)Special Inspection (6)
01/08/2025
Violation issued (ECB, closed)
Construction
01/03/2022
Permit issued — General Construction
Q00482042-I1-GC
09/15/2021
Filed — Alteration
Q00482042-P1
09/15/2021
Filed — Alteration
REPLACING PLUMBING FIXTURES WITH NEW AT CELLR,1ST AND 2ND FLR AS PER PLAN. NO CHANGE IN USE EGRESS OR OCCUPACY.
Q00592176-I1
09/13/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shamsul Siddique
09/13/2021
Special inspection requirement — Fire-Resistance Rated Construction
Shamsul Siddique
09/13/2021
Special inspection requirement — Lighting in dwelling units
Shamsul Siddique
09/13/2021
Special inspection requirement — Interior lighting power
Shamsul Siddique
09/12/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
09/12/2021
Special inspection requirement — Energy Code Compliance Inspections
07/23/2021
Permit issued — General Construction
Q00482042-I1-GC
07/20/2021
Filed — Alteration
Q00482042-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedPULATANI BUILDERS INC01/03/2022
DOB NOWGeneral ConstructionPermit IssuedPULATANI BUILDERS INC07/23/2021
1 project · most recent 09/15/2021
Gas Water/Sanitary
FiledStatusContractorScope
09/15/2021——Gas, Water/Sanitary
3 projects · most recent 02/29/2024
General Wiring
FiledStatusContractorScope
02/29/2024CompleteE & M ELECTRICAL NY CORP—
10/30/2023CompleteE & M ELECTRICAL NY CORPGeneral Wiring
09/19/2023CompleteE & M ELECTRICAL NY CORPGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
09/13/2021Fire-Resistant Penetrations and JointsShamsul Siddiquespecial
09/13/2021Fire-Resistance Rated ConstructionShamsul Siddiqueprogress
09/13/2021Lighting in dwelling unitsShamsul Siddiqueenergy_progress
09/13/2021Interior lighting powerShamsul Siddiqueenergy_progress
09/12/2021Fire-Resistant Penetrations and Joints—special
09/12/2021Energy Code Compliance Inspections—progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/27/2026Q00482042-I1Request digital key ↗
08/27/2026Q00482042-P1Request digital key ↗
08/27/2026Q00592176-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026Q00592176-I1Open ↗
08/13/2026Q00482042-P1Open ↗
08/13/2026Q00482042-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/26/2026Q00482042-P1Open ↗
08/26/2026Q00482042-P1Open ↗
08/26/2026Q00482042-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q00482042-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026Q00482042-P1Open ↗
08/13/2026Q00482042-I1Open ↗
08/13/2026Q00592176-I1Open ↗