← Back
Two family converted from one family
104-25 189 STREET
QUEENS · St. Albans · BIN 4457649
💬 Discuss this project
1910Year Built
2.75Stories
B3Building Class
R2Zoning
1,883 sfGross Floor Area
2Units
Two family converted from one family · 3,742 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof1p · 1 filing · 8 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC105/23/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
VOLTAIC SOLAIRE LLCGeneral Contractor303/21/2026
BERGER QUALITY ELEC'L CONElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854105/23/2024
Building Lifecycle
All (7)Filed (1)Permit Issued (1)Special Inspection (5)
06/04/2024
Permit issued — Solar
Q01055795-I1-SL
05/23/2024
Filed — Alteration
Installation of PV system on existing roof, no change to egress or occupancy
Q01055795-I1
05/23/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/23/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
05/23/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/23/2024
Special inspection requirement — Final
TOM PETERSEN
05/23/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedVOLTAIC SOLAIRE LLC06/04/2024
1 project · most recent 05/07/2024
FiledStatusContractorScope
05/07/2024Permit IssuedBERGER QUALITY ELEC'L CON—
1 project · most recent 05/23/2024
FiledStatusContractorScope
05/23/2024Permit IssuedVOLTAIC SOLAIRE LLC19 panels, 7.79 kw, 1,883 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/23/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/23/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
05/23/2024Energy Code Compliance InspectionsTOM PETERSENprogress
05/23/2024FinalTOM PETERSENprogress
05/23/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026Q01055795-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/28/2026Q01055795-I1Open ↗
08/28/2026Q01055795-I1Open ↗
08/28/2026Q01055795-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026Q01055795-I1Open ↗
08/28/2026Q01055795-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01055795-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01055795-I1Open ↗