← Back
Two family converted from one family
104-28 194 STREET
QUEENS · St. Albans · BIN 4232927
💬 Discuss this project
1940Year Built
2.5Stories
B3Building Class
R2Zoning
1,812 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family converted from one family · 4,000 sf lot · 0.45 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof1p · 1 filing · 8 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC107/14/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
VOLTAIC SOLAIRE LLCGeneral Contractor303/21/2026
BERGER QUALITY ELEC'L CONElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854107/14/2024
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Violation (1)Special Inspection (5)
07/17/2024
Permit issued — Solar
Q01080566-I1-SL
07/14/2024
Filed — Alteration
Installation of PV system on existing roof, no change to egress of use of occupancy
Q01080566-I1
07/14/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
07/14/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
07/14/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
07/14/2024
Special inspection requirement — Final
TOM PETERSEN
07/14/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
09/12/2008
Violation issued (HPD, open)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offVOLTAIC SOLAIRE LLC07/17/2024
1 project · most recent 07/03/2024
FiledStatusContractorScope
07/03/2024CompleteBERGER QUALITY ELEC'L CON—
1 project · most recent 07/14/2024
FiledStatusContractorScope
07/14/2024Signed-offVOLTAIC SOLAIRE LLC11 panels, 4.51 kw, 1,812 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/14/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
07/14/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
07/14/2024Energy Code Compliance InspectionsTOM PETERSENprogress
07/14/2024FinalTOM PETERSENprogress
07/14/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/28/2026Q01080566-I1Open ↗
08/28/2026Q01080566-I1Open ↗
08/28/2026Q01080566-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026Q01080566-I1Open ↗
08/28/2026Q01080566-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01080566-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01080566-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01080566-I1Open ↗