← Back
Two family converted from one family
104 PENNSYLVANIA AVENUE
BROOKLYN · East New York (North) · BIN 3083502
💬 Discuss this project
1901Year Built
3Stories
B3Building Class
C4-4DZoning
3,300 sfGross Floor Area
2Units
Two family converted from one family · 2,767 sf lot · 1.19 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalGeneral
Roof4p · 1 filing · 6 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC104/30/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CENTURION SOLAR ENERGYGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854104/30/2025
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
01/12/2026
Signed off — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
B01218165-I1
05/29/2025
Permit issued — Solar
B01218165-I1-SL
04/30/2025
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
B01218165-I1
04/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
04/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
04/29/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
04/29/2025
Special inspection requirement — Final
TOM PETERSEN
04/29/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offCENTURION SOLAR ENERGY05/29/2025
BIS—ISSUEDZYCH CONSTRUCTION AND MAINTENANC06/17/1996
1 project · most recent 04/27/2025
FiledStatusContractorScope
04/27/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/29/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
04/29/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
04/29/2025Energy Code Compliance InspectionsTOM PETERSENprogress
04/29/2025FinalTOM PETERSENprogress
04/29/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026B01218165-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B01218165-I1Open ↗
09/01/2026B01218165-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/21/2026B01218165-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026B01218165-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/21/2026B01218165-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01218165-I1Open ↗