ECB01/29/2025OBSERVED AROUND EXPO#3 THE CONDITIONS OF THE CONSTRUCTION FENCE NOT AS PER B.C 3307.7.7. THE CONSTRUCTION FENCE PANEL AND THE WOOD POST USED TO HOLD UP THE PANEL WAS ON THE GROUND LEAVING A PORTION OF THE SITE$5K due
ECB01/29/2025OBSERVED A SIDE WALK SHED INSTALLED AS OHP ON EXPO#3 . DEPARTMENT RECORDS SHOWS SHED PERMIT EXPIRED ON 1/03/2022. AND CONDITIONS OF THE PARAPET NOT MAINTAIN AS PER CODE$6K due
DOB03/20/2024FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB01/10/2024ATOI I OBSERVED CONTRACTOR FAILURE TO COMPLY WITH DM -SEQUENCE.STAGE 35 REFLECTS THAT CONTRACTOR SHALL INSTALL TEMP. SUPPORT FOR 1ST FLOOR SLAB PRIOR TO THE INSTALLATION OF STEEL TRUSS BRACING.TEMP. SUPPORT UND$3K due
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
ECB01/20/2023FAILURE TO INSTITUTE AND MAINTAIN ADEQUATE SAFETY MEASURES.NOTE AT THETIME OF INSPECTION RESPONDING TO COMPLAINT#3798882 WHERE FDNY REQUEST AN INSPECTION DUE TO A WORKER WHO FELL FROM THE STRUCTURE.INSPECTION R$25K due
ECB01/13/2023FAILURE TO INSTITUTE AND MAINTAIN ADEQUATE SAFETY MEASURES.NOTE-AT THETIME OF INSPECTION RESPONDING TO A COMPLAINT 3798882 WHERE FDNY REQUEST ON INSPECTION DUE TO A WORKER FELL FROM THE STRUCTURE.INSPECTION REV$25K due
ECB12/21/2022INADEQUATE LIGHTING-BC3307.6.4.8 I OBSERVED 2 STORY CLOSED JOBSITE UNDERGOING FULL DEMOLITION, WITH SIDEWALK SHED(SWS) AT EXP1 AND 4 HAVING INADEQUATE LIGHTING(LIGHTS ARE OFF). THIS DARK CONDITION OF POOR VISIB$2K due
ECB08/15/2022NOTE: OBSERVED A SIDEWALK SHED AT EXP1, 2, 3, 4 & PEDESTRIAN WALKING UNDER IT. ALSO OBSERVED SIDEWALK SHED HAVE MISSING SCREWCAPS SEVERAL AREA CREATING SHARP EDGE(3307.6.5.6) & CUT HAZARD CONDITION FOR PEDESTRI$2K due
ECB08/10/2022AT THE TIME OF MY INSPECTION OBSERVED APPROXIMATELY 60 FEET OF SIDEWALK SHED AT EXP#1 AND 90 FEET OF SIDEWALK SHED AT EXP#4 WAS NOT PROVIDED WITH LIGHTING AS REQUIRE ON UNDERSIDE. FAILURE TO PROVIDE AND MAINT$2K due
ECB04/05/2022PEDESTRIAN PROTECTION DOESNT MEET CODE SPECS.NOTE:ATO MY INSP OBSERVEDSWS W/NO LIGHTING PROVIDED UNDERSIDE TO PROTECT SAFETY OF PEDESTRIANS ACCESSING SWS DURING DARK HRS.THIS CREATES HAZARDOUS CONDITION FOR PED$1K due
ECB03/23/2022PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.AT THE TIME OFMY INSPECTION OF A SIDEWALK SHED I OBSERVED THAT THERE WERE NO UNDERSIDE LIGHTING PROVIDED TO PROTECT THE SAFETY OF THE PEDESTRIANS USING DA$1K due
ECB02/22/2022BC3314.1 UNSAFE SUPPORTED SCF NOTE ATOI I OBSERVED SUPPORTED SCF IN PLACE W/FOLLOWING UNSAFE&HAZARDOUS CONDITIONS (1)DEBRIS NETTING LOOSE&DAMAGED(2)PLANKS NOT SECURED ON UPPER LEVEL CREATING HAZARDOUS CONDITION$2K due
ECB02/17/2022BC3314.1 UNSAFE SUPPORTED SCAFFOLD.NOTE:AT TIME OF INSPECTION OBSERVED SUPPORTED PIPE SCAFFOLD IN PLACE DEBRIS NETTING LOOSE & DAMANGED CREATING UNSAFE CONDITION FOR PEDESTRIANS FALLING MATERIALS DEBRIS ALL ARE$1K due
ECB01/18/2022BC 3307.6.4.8 LIGHTING NOTE:AT THE TIME OF MY INSPECTION I OBSERVED APPROXIMATELY 15 FEET OF SIDEWALK SHED AT EXPOSURE ONE WAS NOT PROVIDED WITH LIGHTING AS REQUIRE ON UNDERSIDE FAILURE TO PROVIDE AND MAINTAIN$1K due
ECB10/19/2021LIGHTING.NOTE-ATOI I OBSERVED LIGHTING FOR SWS WASNT OPERATING&WAS VERY DARK.THIS CREATES UNSAFE CONDITION FOR PEDESTRIANS (TRIP,FALL,ROBBERY).UNDERSIDE OF SWSS SHALL BE ILLUMINATED@ALL TIMES EITHER BY DAYLIGHT$3K due
DOB10/18/2021FAILURE TO MAINTAIN PROPERTY IN A SAFE AND CODE COMPLIANT MANNER, PART IAL DEMOLITION PERFORMED UNDER #321995249 CONTRARY TO APPROVED DRAWING WORK CEASED ON 5/27/21 AFTER WORKER FATALITY AT SITE.FILED B00608717 TO REMEDY AND SAFEGUARD P/DEMO OPERATIOS,COMPLY WITH CODE AND IMMEDIATELY MAINTAIN AND SFAEGUARD-PROPERTY ++
ECB10/16/2021BC3314.8 INADEQUATE DEBRIS NETTING.AT TIME OF INSPECTION RESPONDING TO COMPLAINT OBSERVED SUPPORTED PIPE SCAFFOLD ERECTED ON TOP OF SIDEWALK SHED AND OBSERVED AT EXP #1 & #2 DEBRIS NETTING HAD LARGE OPENING AND$2K due
ECB07/23/2021BC3301.1.1.2-FIRE CODE NOTE AT THE TIME OF MY INSPECTION OF A 2 STORY DEMO SITE IN PROGRESS I OBSERVED INADEQUATE STORAGE OF GASOLINE CREATING A HAZARDOUS CONDITION ON SITE GAS CAN WAS NOT STORED IN A SAFE MANN$2K due
ECB07/23/2021BC3303.7.3.1-TEMPORARY LIGHTING FOR CONSTRYCTION SITES NOTE AT THE TIME OF MY INSPECTION OF A 2 STORY DEMO SITE I OBSERVED THERE WAS NO TEMPORARY LIGHTING THROUGHOUT SITE CREATING A UNSAFE CONDITION FOR 1ST RES$1K due
ECB07/23/2021PERMIT HOLDER FAILED TO ENSURE WORKERS RECEIVE SITE SAFETY ORIENTATION. NOTE-AT THE TIME OF INSPECTION RESPONDING TO COMPLAINT OF A WORKER FELL FROM STRUCTURE. INSPECTION REVEALS THAT THERE WAS NO SITE SAFETY O$2K due
ECB07/23/2021BC3301.6-DESIGN ,SIZES AND CAPACITY OF MATERIALS STRUCTURES TEMPRARY CONSTRUCTION AND EQUIPMENT NOTE AT THE TIME OF MY INSEPCTION FO A 2 STORY DEMO SITE I OBSERVED FALL PROTECTION CABLES ATTACHED TO SUPPORTED P$2K due
ECB07/23/2021BC 3301.1.2 FIRE CODE NOTE:AT THE TIME OF INSPECTION OF A 2 STORY DEMOSITE IN PROGRESS UPON INSPECTION I OBSERVED GAS/DIESEL GENERATOR INSIDE SITE ON THE 1ST FLOOR.THERE WERE NO FDNY PERMITS FOR THIS GENERATOR$2K due
ECB07/23/2021STORAGE ON THE TOP OF SIDEWLAK SHED NOTE AT THE TIME OF MY INSPECTION OF A 2 STORY DEMO SITE I OBSERVED AS WALKING THE SIDEWALK SHED THAT WAS IN PLACE CONSTRUCTION MATERIAL SCAFFOLD EQUIPMENT AND DEBRIS$1K due
ECB07/23/2021FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS NOTE AT THE TIME OF MY INSPECTION OF A 2 STORY DEMO SITE I OBSERVED LARG EPILE APPROX 30 CUBIS YARDS OF COMBUSTIBLE MATEIRAL STORED$2K due
ECB07/23/2021BC 3315.2 PLATFORMS NOTE:AT THE TIME OF INSPECTION I OBSERVED PLATFORMOVER LARGE OPENING IN FLOOR ON THE SECOND FLOOR.THERE WAS NO DESIGN DRAWINGS ONSITE FOR THIS PLATFORM NO SIGNAGE,GUARDRAILS TO ENCLOSE AREA$2K due
ECB07/23/2021FAILURE TO COMMUNICATE REQURIED INFORMATION TO WORKERS DURING PRE SHIFT SAFETY MEETING NOTE AT THE TIME OF MY INSPECTION RESPONDING TO A COMPLAINT OF A WORKERS FELL FRON STRUCTURE INSPECTION REVEALS THERE WAS N$2K due
ECB07/23/2021BC3314.1-UNSAFE SUPPORTED PIPE SCAFFOLD NOTE AT THE TIME OF MY INSPECTION I OBSERVED AS I WALKED THE SUPPORTED PIPE SCAFFOLD THAT WAS IN PLACE THERE WERE MISSING GUARDRAILS AND MISSING DIAGONAL BRACING CREATING$2K due
ECB07/23/2021FAILURE TO ENSURE EACH WORKER IS IN COMPLIANCE WITH BC 33212.1 NOTE:ATTHE TIME OF INSPECTION OF A 2 STORY DEMO SITE IN PROGRESS UPON REQUESTFOR SST TRAINING CARD FOR WORKER REY LICONA AND PLOOF OF SST TRAINING$5K due
ECB05/27/2021BC3301.13.1-SITE SAFETY PLAN NOTE AT THE TIME OF MY INSPECTION FO A 2 STORY DMEO SITE RESPONDING TO A COMPLAINT OF WORKER FELL FROM STRUCTURE NOTE UPON REQUEST FOR SITE SAFETY PLAN TO COMPETTENT PERSON ON SITE$2K due
DOB05/27/2021FAILURE TO SAFETY MEASURES DURING LEVEL DEMO OPERATIONS WORKER WORKING ON ROOF LEVEL PERFORMING DEMO OPERATIONS WAS NOT SECURED TO LIFE LINE AND FELL FROM ROOF LEVEL TO GROUND CAOSING FATAL INJURY
ECB05/27/2021FAILURE TO PROMPTLY NOTIFY THE DEPT OF AN ACCIDENT THAT OCCURED ON A CONSTRUCTION SITE.NOTE A THE TIME OF INSPECTION RESPONDING TO COMPLAINTREPORTED BY FDNY 3798882.INSPECTION REVEALS THAT THE PERMIT HOLDER DID$25K due
ECB05/27/2021FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY BC CHAPTER 33NOTE:AT THE TIME OF INSPECTION OF A 2 STORY DEMO SITE IN PROGRESS UPONREQUEST FOR APPROVED DEMO PLANS FROM COMPETENT PERSON OF SITE ELISEO L$2K due
ECB05/27/2021FAILURE TO INSTITUTE AND MAINTAIN SAFETY EQUIPMENT MEASURES AND TEMPORARY CONSTRUCTION NO GUARD RAILS NOTE AT THE TIME OF MY INSPECTION OF A 2 STORY DEMO SITE I OBSERVED MULTIPLE LOCATIONS WHERE GUARDRAILS WERE$5K due
ECB05/07/2021PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS-NO UNDERSIDE LIGHTING FOR SWS. AT THE TIME OF MY INSPECTION OF A SIDEWALK SHED AT THE ABOVE ADRESS,I OBSERVED THAT THERE WERE NO UNDERSIDE LIGHTING PROVID$1K due
ECB08/15/2025OBSERVED PROPOSED 7-STORY MIXED-USE BUILDING, SITE INACTIVE. FENCE INTACT BUT LACKING ADEQUATE POSTED PERMITS AND INFORMATION PANELS. VIEWING PANELS ON FENCE WERE BLOCKED/OBSCURED, VIOLATING BC 3307.7 -( GC# 29Nothing owed — awaiting certificate of correction
ECB07/23/2021CONSTRUCTION SUPERINTENDENT FAILED TO IMMEDIATELY NOTIFY THE DEPARTMENT OF CONDITIONS.NOTE:AT THE TIME OF INSPECTION RESPONDING TO A COMPLAINT(3798882)NOTIFIED BY THE FDNY THAT A WORKER FELL FROM THE STRUCTURENothing owed — awaiting certificate of correction
ECB07/23/2021CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER RULE.THE FOLLOWING HAZARDOUS AND UNSAFE CONDITIONS WAS OBSRVED AND ISSUED ON THIS DATE(1)INADEQUATE SAFETY MEASURES FOR DEMO OPERATIONS(2)NO SITE SAFENothing owed — awaiting certificate of correction