← Back
Five to six families
1047 SUMMIT AVNUE
BRONX · BIN 2115020
💬 Discuss this project
2006Year Built
3Stories
C2Building Class
R7-1Zoning
8,760 sfGross Floor Area
6Units
Rent Stabilized66 Open Violations ▸FDNY Report ↗
Five to six families · Owner of record: SUMMIT PROPERTY GARDENS 2 LLC · 4,024 sf lot · 2.18 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalGeneral
Floor 315p · 1 filing · 20 docs
Floor 214p · 1 filing · 20 docs
Floor 114p · 1 filing · 20 docs
Cellar22p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SUMMIT PROPERTY GARDENS 2 LLC1203/22/2026
SUMMIT PROPERTY GARDENTS103/22/2026
KINGS COLLEGE REAL ESTATE303/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/07/2016$751K—— → —$86/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BAOBAB ARCHITECTS P.C.607/14/2025
ADVANCED ENGINEERING & INSPECT. PLL407/14/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEVM EXPEDITORS803/21/2026
ELLIPSES DESIGN603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRECISION BUILD USA INCGeneral Contractor603/21/2026
KJK ELECTRIC INCElectrical103/22/2026
VILLAGE P & H NY INCFire Protection107/08/2026
PRECISION BUILDERS USAGeneral Contractor107/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE20501007/14/2025
Building Lifecycle
All (189)Filed (10)Permit Issued (5)Signed Off (3)Violation (60)Inspection (13)Objection (68)Special Inspection (30)
07/29/2025
Signed off — Alteration CO
SPRINKER WORK TYPE FILED AS SUBSEQUENT DOCUMENT TO JOB #X00565161.
X00565161-S3
07/23/2025
Objection resolved — Addressed
07/23/2025
Special inspection requirement — Lighting controls
PAUL MARINO
07/23/2025
Special inspection requirement — Air barrier - visual inspection
PAUL MARINO
07/23/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
07/23/2025
Special inspection requirement — Fenestration areas
PAUL MARINO
07/23/2025
Special inspection requirement — Insulation placement and R values
PAUL MARINO
07/23/2025
Special inspection requirement — Lighting in dwelling units
PAUL MARINO
07/23/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
PAUL MARINO
07/23/2025
Special inspection requirement — Interior lighting power
PAUL MARINO
07/23/2025
Special inspection requirement — Fenestration air leakage
PAUL MARINO
07/23/2025
Special inspection requirement — Exterior lighting power
PAUL MARINO
07/23/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
07/23/2025
Special inspection requirement — Fire-Resistance Rated Construction
PAUL MARINO
07/21/2025
Objection raised — Other
07/14/2025
Filed — Alteration CO
SPRINKER WORK TYPE FILED AS SUBSEQUENT DOCUMENT TO JOB #X00565161.
X00565161-A2
07/14/2025
Filed — Alteration CO
SPRINKER WORK TYPE FILED AS SUBSEQUENT DOCUMENT TO JOB #X00565161.
X00565161-P8
03/05/2025
Signed off — Alteration CO
SPRINKER WORK TYPE FILED AS SUBSEQUENT DOCUMENT TO JOB #X00565161.
X00565161-S2
03/05/2025
Signed off — Alteration CO
SPRINKER WORK TYPE FILED AS SUBSEQUENT DOCUMENT TO JOB #X00565161.
X00565161-S4
03/05/2025
Special inspection requirement — Final
JAMES SCHAEFER
03/05/2025
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
03/05/2025
Special inspection requirement — Heating Systems
PAUL MARINO
03/05/2025
Special inspection requirement — HVAC-R and service water heating equipment
03/05/2025
Special inspection requirement — HVAC-R and service water heating system controls
03/05/2025
Special inspection requirement — Mechanical Systems
PAUL MARINO
03/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
03/05/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
01/23/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/12/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/22/2024
Violation issued (HPD, closed)
B
03/22/2024
Violation issued (HPD, closed)
B
03/22/2024
Violation issued (HPD, closed)
C
03/22/2024
Violation issued (HPD, closed)
B
03/22/2024
Violation issued (HPD, closed)
B
01/25/2024
Objection resolved — Addressed
01/23/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/11/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/26/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
12/19/2023
Objection raised — Scope
12/18/2023
Filed — Alteration CO
SPRINKER WORK TYPE FILED AS SUBSEQUENT DOCUMENT TO JOB #X00565161.
X00565161-P6
12/14/2023
Special inspection requirement — Lighting in dwelling units
PAUL MARINO
12/14/2023
Special inspection requirement — Fenestration air leakage
PAUL MARINO
12/14/2023
Special inspection requirement — Insulation placement and R values
PAUL MARINO
12/14/2023
Special inspection requirement — Lighting controls
PAUL MARINO
12/14/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
PAUL MARINO
12/14/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
12/14/2023
Special inspection requirement — Air barrier - visual inspection
PAUL MARINO
12/14/2023
Special inspection requirement — Fenestration areas
PAUL MARINO
12/14/2023
Special inspection requirement — Interior lighting power
PAUL MARINO
12/14/2023
Special inspection requirement — Exterior lighting power
PAUL MARINO
09/07/2023
Violation issued (HPD, closed)
A
09/07/2023
Violation issued (HPD, open)
B
08/31/2023
Objection resolved — Addressed
08/14/2023
Objection raised — Fire_Protection
08/10/2023
Violation issued (ECB, closed)
Unknown
08/10/2023
Violation issued (ECB, closed)
Construction
08/10/2023
Violation issued (ECB, closed)
Construction
08/09/2023
Filed — Alteration CO
SPRINKER WORK TYPE FILED AS SUBSEQUENT DOCUMENT TO JOB #X00565161.
X00565161-P5
08/03/2023
Violation issued (ECB, closed)
Construction
08/03/2023
Violation issued (ECB, closed)
Unknown
Latest 60 of 189 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offPRECISION BUILD USA INC05/05/2023
DOB NOWGeneral ConstructionPermit IssuedPRECISION BUILD USA INC05/03/2023
DOB NOWSprinklersSigned-offVILLAGE P & H NY INC01/27/2023
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.10/24/2022
DOB NOWGeneral ConstructionPermit IssuedPRECISION BUILDERS USA09/12/2022
BISPLISSUEDA P PLUMBING&HEATING INC02/26/2007
BISEQISSUEDAQUINO GENERAL CONSTRUCTION INC.12/06/2006
BISEQISSUEDAQUINO GENERAL CONSTRUCTION INC.08/01/2006
1 project · most recent 07/14/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/14/2025Signed-offPRECISION BUILD USA INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MSZ-GL06NA. 6,000 BTU · Fan Coil Indoor ×2
MSZ-GL18NA. 12,000 BTU · Fan Coil Indoor ×1
MUZGL18NA. 21,600 BTU · Heat Pump Outdoor ×1
MXZ2C20NA3. 25,500 BTU · Vrf Outdoor ×1
Ventilation
Nutone AEN110. 50 CFM · Exhaust Fan ×1
QTXEN150. 100 CFM · Kitchen Exhaust ×1
1 project · most recent 07/14/2025
Sprinkler System
FiledStatusContractorScope
07/14/2025Signed-offPARAMOUNT SERVICES, LLCSprinkler System
1 project · most recent 07/14/2025
Water/Sanitary
FiledStatusContractorScope
07/14/2025Signed-offAMERICAN STANDARD P&H CORWater/Sanitary
2 projects · most recent 10/25/2023
General Wiring
FiledStatusContractorScope
10/25/2023Permit IssuedTFK ELECTRIC CORPGeneral Wiring
11/16/2022CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
01/23/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/12/2024Pass-Final CND-Occupancy InspectionPassView ↗
01/23/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/11/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/26/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
06/13/2023No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
06/08/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/04/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/19/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/05/2023Pass-Final CND-Occupancy InspectionPassView ↗
03/31/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
12/08/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/08/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 66
DateRequirementInspectorRole
07/23/2025Lighting in dwelling unitsPAUL MARINOenergy_progress
07/23/2025Interior lighting powerPAUL MARINOenergy_progress
07/23/2025Insulation placement and R valuesPAUL MARINOenergy_progress
07/23/2025Fenestration areasPAUL MARINOenergy_progress
07/23/2025Fenestration air leakagePAUL MARINOenergy_progress
07/23/2025Exterior lighting powerPAUL MARINOenergy_progress
07/23/2025HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
07/23/2025Air barrier - visual inspectionPAUL MARINOenergy_progress
07/23/2025Lighting controlsPAUL MARINOenergy_progress
07/23/2025Fenestration and door U-factor and product ratingsPAUL MARINOenergy_progress
07/23/2025Fire-Resistant Penetrations and JointsPAUL MARINOspecial
07/23/2025Fire-Resistance Rated ConstructionPAUL MARINOprogress
03/05/2025Heating SystemsPAUL MARINOspecial
03/05/2025Energy Code Compliance InspectionsPAUL MARINOprogress
03/05/2025FinalJAMES SCHAEFERprogress
03/05/2025HVAC-R and service water piping design and insulation—energy_progress
03/05/2025HVAC-R and service water heating system controls—energy_progress
03/05/2025HVAC-R and service water heating equipment—energy_progress
03/05/2025Fire-Resistant Penetrations and JointsPAUL MARINOspecial
03/05/2025Mechanical SystemsPAUL MARINOspecial
12/14/2023Exterior lighting powerPAUL MARINOenergy_progress
12/14/2023Interior lighting powerPAUL MARINOenergy_progress
12/14/2023Fenestration areasPAUL MARINOenergy_progress
12/14/2023Air barrier - visual inspectionPAUL MARINOenergy_progress
12/14/2023HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
Latest 25 of 66.
▾Documents — 113 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/22/2026X00565161-S2Request digital key ↗
08/22/2026X00565161-A2Request digital key ↗
08/22/2026X00565161-S4Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZoning Exhibit form (1-5)6
08/13/2026X00565161-P2Open ↗
08/13/2026X00565161-P5Open ↗
08/13/2026X00565161-P6Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X00565161-I1Open ↗
▸Seals & Professional Certifications73
▸DOB NOWProgress Inspector Seal & Signature52
08/28/2026X00565161-P6Open ↗
08/28/2026X00565161-P6Open ↗
08/28/2026X00565161-P6Open ↗
Showing 3 of 52 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
09/13/2026X00565161-S4Open ↗
09/13/2026X00565161-S4Open ↗
08/28/2026X00565161-P6Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/22/2026X00565161-A2Open ↗
08/22/2026X00565161-P8Open ↗
08/22/2026X00565161-P6Open ↗
Showing 3 of 10 on file for this type
▸Safety & Tenant Protection9
▸DOB NOWStreet Tree Checklist6
08/22/2026X00565161-A2Open ↗
08/15/2026X00565161-P6Open ↗
08/15/2026X00565161-P5Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X00565161-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026X00565161-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026X00565161-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026X00565161-I1Open ↗
▸Other Documents13
▸DOB NOWDHCR Document12
08/13/2026X00565161-A2Open ↗
08/13/2026X00565161-P5Open ↗
08/13/2026X00565161-P2Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWFinal Survey1
08/13/2026X00565161-I1Open ↗