← Back
Primarily 2 family with 1 store or office
105-40 CROSS BAY BOULEVARD
QUEENS · Ozone Park · BIN 4191010
💬 Discuss this project
1920Year Built
2Stories
S2Building Class
R6BZoning
1,152 sfGross Floor Area
3Units
12 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: 10540 CROSSBAY LLC · 1,508 sf lot · 0.76 FAR built · Flood zone X
Locations of Work
Architecture
Floor 11p · 1 filing · 10 docs
Cellar1p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
10540 CROSSBAY1207/08/2026
OWNER OF 105-10 CROSSBAY103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SELF EMPLOYED202/18/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Younes Abouyaala PE103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CJ HEATING & MECHANICAL CPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519202/18/2022
Building Lifecycle
All (31)Filed (2)Permit Issued (2)Signed Off (2)Violation (15)Inspection (3)Special Inspection (7)
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/17/2025
Violation issued (ECB, closed)
Boilers
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/20/2022
Signed off — Alteration
Q00546362-I1
12/20/2022
Signed off — Alteration
Q00546362-S1
09/28/2022
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
09/27/2022
Permit issued — Boiler Equipment
Q00546362-S1-BE
09/16/2022
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
02/18/2022
Filed — Alteration
Q00546362-S1
12/14/2021
Inspection — Fail-Final Boiler Equipment Inspection
Fail
View inspection ↗
10/28/2021
Permit issued — Boiler Equipment
Q00546362-I1-BE
07/01/2021
Filed — Alteration
Q00546362-I1
06/24/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
06/24/2021
Special inspection requirement — Heating Systems
Younes Abouyaala
06/24/2021
Special inspection requirement — Lowest Floor Elevation
Younes Abouyaala
06/24/2021
Special inspection requirement — Permanent certificate
Younes Abouyaala
06/24/2021
Special inspection requirement — HVAC-R and service water heating equipment
Younes Abouyaala
06/24/2021
Special inspection requirement — HVAC-R and service water heating system controls
Younes Abouyaala
06/24/2021
Special inspection requirement — Maintenance information
Younes Abouyaala
05/15/2014
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/31/2009
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/02/2008
Violation issued (ECB, closed)
Construction
01/03/2008
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/19/2007
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/06/2006
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/31/2005
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2000
Violation issued (ECB, closed)
Boilers
06/28/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentSigned-offCJ HEATING & MECHANICAL C09/27/2022
DOB NOWBoiler EquipmentSigned-offCJ HEATING & MECHANICAL C10/28/2021
BISPLISSUEDCJ HEATING & MECHANICAL C10/27/2021
BISPLISSUEDCJ HEATING & MECHANICAL C01/14/2020
BISPLISSUEDCJ HEATING & MECHANICAL C12/28/2018
BISPLISSUEDPLBG P & H INC11/13/2017
BISOTISSUEDN/A05/16/2017
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
09/28/2022Pass-Final Boiler Equipment InspectionPassView ↗
09/16/2022Pass-Final Boiler Equipment InspectionPassView ↗
12/14/2021Fail-Final Boiler Equipment InspectionFailView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
06/24/2021Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
06/24/2021Heating SystemsYounes Abouyaalaspecial
06/24/2021Lowest Floor ElevationYounes Abouyaalaprogress
06/24/2021Permanent certificateYounes Abouyaalaenergy_progress
06/24/2021HVAC-R and service water heating equipmentYounes Abouyaalaenergy_progress
06/24/2021HVAC-R and service water heating system controlsYounes Abouyaalaenergy_progress
06/24/2021Maintenance informationYounes Abouyaalaenergy_progress
▾Documents — 52 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026Q00546362-S1Request digital key ↗
08/27/2026Q00546362-I1Request digital key ↗
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION4
01/02/2020440444306Open ↗
12/13/2019440444306Open ↗
10/23/2017440444306Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION4
01/21/2020440444306Open ↗
01/02/2019440444306Open ↗
11/13/2017440444306Open ↗
Showing 3 of 4 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
07/13/2017421474005Open ↗
▸Seals & Professional Certifications12
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
10/23/2017440444306Open ↗
05/24/2017421474005Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
07/13/2017421474005Open ↗
05/24/2017421474005Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/27/2026Q00546362-S1Open ↗
08/27/2026Q00546362-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026Q00546362-I1Open ↗
08/23/2026Q00546362-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/23/2017440444306Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
05/24/2017421474005Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/23/2017440444306Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q00546362-I1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
01/02/2020440444306Open ↗
12/13/2019440444306Open ↗
▸BISSCHEDULE B - PLUMBING1
10/23/2017440444306Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
10/23/2017440444306Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/27/2026Q00546362-S1Open ↗
08/27/2026Q00546362-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/23/2017440444306Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
07/13/2017421474005Open ↗
05/24/2017421474005Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
12/21/2022440444306Open ↗
07/13/2017421474005Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
12/21/2022440444306Open ↗
10/23/2017440444306Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/23/2017440444306Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00546362-I1Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
12/21/2022440444306Open ↗
10/23/2017440444306Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
12/22/2022440444306Open ↗
07/13/2017421474005Open ↗
▸BISSUPERSEDING LETTER1
01/02/2019440444306Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
12/21/2022440444306Open ↗
10/23/2017440444306Open ↗
07/13/2017421474005Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms5
▸BISADDITIONAL INFORMATION2
03/10/2020440444306Open ↗
01/07/2020440444306Open ↗
▸BISEFILING COVER SHEET1
05/24/2017421474005Open ↗
▸BISBOROUGH INTAKE FORM1
12/13/2019440444306Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/23/2017440444306Open ↗