← Back
Two family converted from one family
105-50 87 STREET
QUEENS · Ozone Park · BIN 4190407
💬 Discuss this project
1920Year Built
2.5Stories
B3Building Class
R4AZoning
—Gross Floor Area
2Units
Two family converted from one family · 0.52 FAR built · Flood zone X
Locations of Work
Electrical
Roof1 filing · 7 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR103/24/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281103/24/2026
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
08/07/2026
Signed off — Alteration
installation of solar panels, rooftop, railed, grid-tied, 19 modules, 7.79 kw
Q01377460-I1
03/30/2026
Permit issued — Solar
Q01377460-I1-SL
03/24/2026
Filed — Alteration
installation of solar panels, rooftop, railed, grid-tied, 19 modules, 7.79 kw
Q01377460-I1
03/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
03/24/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
03/24/2026
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
03/24/2026
Special inspection requirement — Final
Mina Makar
03/24/2026
Special inspection requirement — Air barrier - visual inspection
Mina Makar
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offMOMENTUM SOLAR03/30/2026
BISOTISSUEDPHILIP TOSCANO02/14/2001
1 project · most recent 03/24/2026
FiledStatusContractorScope
03/24/2026CompleteISLAND ELECTRIC CORP—
1 project · most recent 03/24/2026
FiledStatusContractorScope
03/24/2026Signed-offMOMENTUM SOLAR19 panels, 7.79 kw, 334 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/24/2026Fire-Resistant Penetrations and JointsMina Makarspecial
03/24/2026Structural Stability – Alterations of existing buildingsMina Makarspecial
03/24/2026Energy Code Compliance InspectionsMina Makarprogress
03/24/2026FinalMina Makarprogress
03/24/2026Air barrier - visual inspectionMina Makarenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/29/2026Q01377460-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026Q01377460-I1Open ↗
08/28/2026Q01377460-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/29/2026Q01377460-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026Q01377460-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/29/2026Q01377460-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/29/2026Q01377460-I1Open ↗