← Back
BuildNYC
Over six families without stores
Oak Hall
105 CARLTON AVENUE · Fort Greene · BIN 3257033
💬 Discuss this project
1930Year Built
5Stories
C1Building Class
R6BZoning
81,625 sfGross Floor Area
140Units
LL97 CoveredRent Stabilized9 Active Violations ▸FDNY Report ↗
Over six families without stores · Owner of record: Pastoral & Educational Services · 27,500 sf lot · 2.97 FAR built · Flood zone X
Locations of Work
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 5Brooklyn Gardens Non-Profit Renovation1 filing · 5 docs
Floor 4Brooklyn Gardens Non-Profit Renovation1 filing · 5 docs
Floor 3Brooklyn Gardens Non-Profit Renovation1 filing · 5 docs
Floor 2Brooklyn Gardens Non-Profit Renovation1 filing · 5 docs
Floor 1Brooklyn Gardens Non-Profit Renovation1 filing · 5 docs
CellarBrooklyn Gardens Non-Profit Renovation1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Brooklyn Community Housing903/22/2026
BCHS210/26/2026
Pastoral & Educational Services103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Urban Architectural Initiatives RA112/18/2025
Edwin Deguzman1—
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB Building Consulting203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Heller Electric CoElectrical103/21/2026
Atn ElectricElectrical103/21/2026
Willdan Electrical of NYElectrical103/22/2026
Building Lifecycle
05/26/2026
Boiler inspection report filed
Initial · no defects · Accepted
05/18/2026
Atoi observed lack of sprinkler coverage on floors 1 through 5 in lounge areas and laundry rooms. Obstructed sprinkler heads in hallways. Per bc…
ECB violation · open
05/18/2026
Class 2 recurring condition: 1) emergency phone inoperative - two-way communication system not functional. Passengers cannot contact authorized…
ECB violation · closed
05/18/2026
Failure to maintain building in code-compliant manner. At time of inspection, observed hole penetrations throughout 5TH floor, 1ST floor in the…
ECB violation · open
05/18/2026
Failure to complie with commissioners order to file a certificate of correction with the deparetment of buildings, for violation # 39148041K. File…
ECB violation · open
165 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISFPISSUEDMaster Fire Systems12/07/2015
BISEQISSUEDPhoenix Bridging12/21/2005
BISEQISSUEDPhoenix Bridging12/06/2005
BISBLISSUEDGJ Plumbing04/15/2002
BISPLISSUEDGJ Plumbing04/15/2002
BISMHISSUEDAwl Industries04/12/2001
BISPLISSUEDCalray Gas Heating12/09/1996
BISEQISSUEDJerrick Waterproofing07/31/1996
BISFSISSUEDD&S Plumbing & Heating11/21/1990
BISPLISSUEDD&S Plumbing & Heating11/21/1990
6 projects · most recent 08/09/2022
General Wiring
FiledStatusContractorScope
08/09/2022CompleteOmd Electrical—
08/09/2021CompleteWilldan Electrical of NY—
05/25/2021CompleteWilldan Electrical of NY—
05/18/2021CompleteWilldan Electrical of NY—
02/13/2020CompleteWilldan Electrical of NY—
04/11/2019CompleteWilldan Electrical of NYGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
12/16/2025Exterior Insulation and Finish Systems (EIFS)—special
12/16/2025Tenant Protection Plan Compliance—special
08/13/2025Energy Code Compliance Inspections—progress
08/13/2025Fire-Resistance Rated Construction—progress
08/13/2025Air barrier - visual inspection—energy_progress
08/13/2025Fire-Resistant Penetrations and Joints—special
08/13/2025Lighting in dwelling units—energy_progress
08/13/2025Masonry—special
36 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account