Licensed parking lot
1051 SHERMAN AVENUE
BRONX · Concourse-Concourse Village · BIN 2814319
💬 Discuss this project
0Year Built
—Stories
G6Building Class
R7-1Zoning
0 sfGross Floor Area
0Units
2 Open Violations 1 unresolved · 1 paperwork only ▸
Licensed parking lot · Owner of record: MASJID NUR-AL ISLAM INC. · 6,942 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureGeneralOther
Permit Issued — active, not yet Signed-off
Filed — no permit issued4 filings · 15 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BRONX SHERIDAN AVENUE ASSOCIATES103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VERSATILE ENGINEERING, P.C.302/07/2024
RSLN ARCHITECTURE PLLC601/13/2023
LMW ENGINEERING GROUP LLC310/07/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RSLN ARCHITECTURE1203/21/2026
MASJID NUR AL ISLAM203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AK PREMIER CONTRACTINGGeneral Contractor2507/08/2026
AK PREMIER CONTR CORPGeneral Contractor1207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MJE CONSULTING ENGINEERIN8522610/10/2022
Building Lifecycle
All (150)Filed (12)Permit Issued (23)Violation (5)Objection (80)Special Inspection (30)
03/18/2026
Permit issued — Structural
X00785025-S3-ST
03/18/2026
Permit issued — Support of Excavation
X00785025-S1-SE
03/18/2026
Permit issued — General Construction
X00785025-I1-GC
03/18/2026
Permit issued — Foundation
X00785025-S2-FO
03/18/2026
Permit issued — Construction Fence
X00785025-S6-FN
02/09/2026
Violation issued (ECB, closed)
Construction
09/18/2025
Permit issued — General Construction
X00785025-I1-GC
09/16/2025
Permit issued — Foundation
X00785025-S2-FO
09/16/2025
Permit issued — Construction Fence
X00785025-S6-FN
09/16/2025
Permit issued — Structural
X00785025-S3-ST
09/16/2025
Permit issued — Support of Excavation
X00785025-S1-SE
08/29/2025
Violation issued (ECB, closed)
Construction
08/28/2025
Violation issued (ECB, closed)
Construction
12/05/2024
Permit issued — Construction Fence
X00785025-S6-FN
07/16/2024
Permit issued — Support of Excavation
X00785025-S1-SE
07/16/2024
Permit issued — General Construction
X00785025-I1-GC
07/12/2024
Permit issued — Foundation
X00785025-S2-FO
07/12/2024
Permit issued — Structural
X00785025-S3-ST
07/12/2024
Permit issued — Mechanical Systems
X00785025-S4-MS
05/24/2024
Permit issued — General Construction
X00785025-I1-GC
05/20/2024
Permit issued — Foundation
X00785025-S2-FO
05/20/2024
Permit issued — Structural
X00785025-S3-ST
05/20/2024
Permit issued — Mechanical Systems
X00785025-S4-MS
05/15/2024
Permit issued — Support of Excavation
X00785025-S1-SE
03/29/2024
Permit issued — Construction Fence
X00785025-S6-FN
02/16/2024
Permit issued — Construction Fence
X00785025-S6-FN
02/13/2024
Objection resolved — Addressed
02/12/2024
Objection raised — Other
02/07/2024
Filed — New Building
Mechanical work in conjunction with New Building Application
X00785025-S6
06/28/2023
Violation issued (ECB, open)
Construction
03/09/2023
Objection resolved — Addressed
03/09/2023
Special inspection requirement — Maintenance information
Evodia Ibrahim
03/09/2023
Special inspection requirement — Lighting in dwelling units
Evodia Ibrahim
03/09/2023
Special inspection requirement — Energy Code Compliance Inspections
Evodia Ibrahim
03/09/2023
Special inspection requirement — Fenestration areas
Evodia Ibrahim
03/09/2023
Special inspection requirement — Air barrier - visual inspection
Evodia Ibrahim
03/09/2023
Special inspection requirement — Vestibules
Evodia Ibrahim
03/09/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Evodia Ibrahim
03/09/2023
Special inspection requirement — Air barrier — testing
Evodia Ibrahim
03/09/2023
Special inspection requirement — Fire-Resistance Rated Construction
Evodia Ibrahim
03/09/2023
Special inspection requirement — Exterior lighting power
Evodia Ibrahim
03/09/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Evodia Ibrahim
03/09/2023
Special inspection requirement — Protection of exposed foundation insulation
Evodia Ibrahim
03/09/2023
Special inspection requirement — Insulation placement and R values
Evodia Ibrahim
03/09/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Evodia Ibrahim
03/09/2023
Special inspection requirement — Metering
Evodia Ibrahim
03/09/2023
Special inspection requirement — Interior lighting power
Evodia Ibrahim
03/09/2023
Special inspection requirement — Electrical motors and elevators
Evodia Ibrahim
03/09/2023
Special inspection requirement — Fenestration air leakage
Evodia Ibrahim
03/09/2023
Special inspection requirement — Lighting controls
Evodia Ibrahim
03/07/2023
Objection raised — Fire_Protection
03/07/2023
Objection resolved — Addressed
01/17/2023
Objection raised — Other
01/13/2023
Filed — New Building
Mechanical work in conjunction with New Building Application
X00785025-P1
01/13/2023
Special inspection requirement — Air barrier — testing
01/13/2023
Special inspection requirement — Exterior lighting power
01/13/2023
Special inspection requirement — Fenestration areas
01/13/2023
Special inspection requirement — Energy Code Compliance Inspections
01/13/2023
Special inspection requirement — Fire-Resistance Rated Construction
01/13/2023
Special inspection requirement — Lighting controls
Latest 60 of 150 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedAK PREMIER CONTR CORP03/18/2026
DOB NOWSupport of ExcavationPermit IssuedAK PREMIER CONTR CORP03/18/2026
DOB NOWGeneral ConstructionPermit IssuedAK PREMIER CONTR CORP03/18/2026
DOB NOWFoundationPermit IssuedAK PREMIER CONTR CORP03/18/2026
DOB NOWConstruction FencePermit IssuedAK PREMIER CONTR CORP03/18/2026
DOB NOWGeneral ConstructionPermit IssuedAK PREMIER CONTR CORP09/18/2025
DOB NOWFoundationPermit IssuedAK PREMIER CONTR CORP09/16/2025
DOB NOWConstruction FencePermit IssuedAK PREMIER CONTR CORP09/16/2025
DOB NOWStructuralPermit IssuedAK PREMIER CONTR CORP09/16/2025
DOB NOWSupport of ExcavationPermit IssuedAK PREMIER CONTR CORP09/16/2025
DOB NOWConstruction FencePermit IssuedAK PREMIER CONTRACTORS12/05/2024
DOB NOWSupport of ExcavationPermit IssuedAK PREMIER CONTRACTORS07/16/2024
DOB NOWGeneral ConstructionPermit IssuedAK PREMIER CONTRACTORS07/16/2024
DOB NOWFoundationPermit IssuedAK PREMIER CONTRACTORS07/12/2024
DOB NOWStructuralPermit IssuedAK PREMIER CONTRACTORS07/12/2024
DOB NOWMechanical SystemsPermit IssuedAK PREMIER CONTRACTORS07/12/2024
DOB NOWGeneral ConstructionPermit IssuedAK PREMIER CONTRACTORS05/24/2024
DOB NOWFoundationPermit IssuedAK PREMIER CONTRACTORS05/20/2024
DOB NOWStructuralPermit IssuedAK PREMIER CONTRACTORS05/20/2024
DOB NOWMechanical SystemsPermit IssuedAK PREMIER CONTRACTORS05/20/2024
DOB NOWSupport of ExcavationPermit IssuedAK PREMIER CONTRACTORS05/15/2024
DOB NOWConstruction FencePermit IssuedAK PREMIER CONTRACTORS03/29/2024
DOB NOWConstruction FencePermit IssuedAK PREMIER CONTRACTORS02/16/2024
1 project · most recent 02/07/2024
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/07/2024Permit IssuedAK PREMIER CONTR CORPHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Trane Horizon (OAK/N Rev 5) - outdoor Air Unit. OAND360D3-D1C400LN-A1H00CB7JL2G52F0B500 337 BTU · Rooftop Unit ×1
Ventilation
Greenheck USF-16, G-140HP-VG, SP-LP0511 (2) 4,500 CFM · Exhaust Fan ×4
1 project · most recent 02/07/2024
Concrete Masonry
FiledStatusContractorScope
02/07/2024Permit IssuedAK PREMIER CONTR CORPConcrete, Masonry
1 project · most recent 02/07/2024
Fence
FiledStatusContractorScope
02/07/2024Permit IssuedAK PREMIER CONTR CORPFence
▾Special Inspection Requirements (DOB NOW) — 72
DateRequirementInspectorRole
03/09/2023Lighting controlsEvodia Ibrahimenergy_progress
03/09/2023Air barrier — testing Evodia Ibrahimenergy_progress
03/09/2023Fenestration and door U-factor and product ratingsEvodia Ibrahimenergy_progress
03/09/2023Fenestration areasEvodia Ibrahimenergy_progress
03/09/2023Lighting in dwelling unitsEvodia Ibrahimenergy_progress
03/09/2023VestibulesEvodia Ibrahimenergy_progress
03/09/2023Insulation placement and R valuesEvodia Ibrahimenergy_progress
03/09/2023Protection of exposed foundation insulationEvodia Ibrahimenergy_progress
03/09/2023Maintenance informationEvodia Ibrahimenergy_progress
03/09/2023Exterior lighting powerEvodia Ibrahimenergy_progress
03/09/2023Exterior Insulation and Finish Systems (EIFS)Evodia Ibrahimspecial
03/09/2023MeteringEvodia Ibrahimenergy_progress
03/09/2023Fire-Resistant Penetrations and JointsEvodia Ibrahimspecial
03/09/2023Interior lighting powerEvodia Ibrahimenergy_progress
03/09/2023Energy Code Compliance InspectionsEvodia Ibrahimprogress
03/09/2023Fire-Resistance Rated ConstructionEvodia Ibrahimprogress
03/09/2023Air barrier - visual inspectionEvodia Ibrahimenergy_progress
03/09/2023Electrical motors and elevatorsEvodia Ibrahimenergy_progress
03/09/2023Fenestration air leakageEvodia Ibrahimenergy_progress
01/13/2023Fire-Resistant Penetrations and Joints—special
01/13/2023Fire-Resistance Rated Construction—progress
01/13/2023Exterior lighting power—energy_progress
01/13/2023Air barrier — testing —energy_progress
01/13/2023Fenestration areas—energy_progress
01/13/2023Lighting controls—energy_progress
Latest 25 of 72.
▾Documents — 158 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch8
08/23/2026X00785025-S6Request digital key ↗
08/23/2026X00785025-S1Request digital key ↗
08/23/2026X00785025-S2Request digital key ↗
Showing 3 of 8 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly4
08/23/2026X08023390-I1Request digital key ↗
08/23/2026X08023392-I1Request digital key ↗
08/23/2026X08023391-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits20
▸BISPLAN / WORK APPROVAL APPLICATION14
08/26/2022240334321Open ↗
04/29/2021240208583Open ↗
12/23/2020220151886Open ↗
Showing 3 of 14 on file for this type
▸BISPLACE OF ASSEMBLY4
05/21/2018220648841Open ↗
05/15/2018220648459Open ↗
05/15/2018220649225Open ↗
Showing 3 of 4 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation1
08/26/2022240334321Open ↗
▸DOB NOWDEP Stormwater Construction Permit1
08/13/2026X00785025-I1Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026X00785025-P1Open ↗
08/13/2026X00785025-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026X00785025-P1Open ↗
08/13/2026X00785025-I1Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
12/02/2008210081392Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X00785025-I1Open ↗
▸Seals & Professional Certifications72
▸DOB NOWProgress Inspector Seal & Signature36
09/02/2026X08023390-I1Open ↗
09/02/2026X00785025-S2Open ↗
09/02/2026X00785025-S2Open ↗
Showing 3 of 36 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature16
09/02/2026X00785025-S2Open ↗
09/02/2026X00785025-S2Open ↗
09/02/2026X00785025-S2Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/23/2026X08023392-I1Open ↗
08/23/2026X00785025-S6Open ↗
08/23/2026X00785025-S1Open ↗
Showing 3 of 12 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
05/21/2018220648841Open ↗
05/15/2018220648459Open ↗
05/15/2018220649225Open ↗
Showing 3 of 4 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
08/26/2022240334321Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/02/2008210081392Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/26/2022240334321Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
12/02/2008210081392Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026X00785025-I1Open ↗
08/13/2026X00785025-P1Open ↗
▸BISSCHEDULE B - PLUMBING1
12/23/2020220151886Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/13/2026X00785025-I1—
▸Safety & Tenant Protection7
▸BISSTREET TREE CHECKLIST2
12/19/2022240334321Open ↗
01/12/2009210081392Open ↗
▸DOB NOWStreet Tree Checklist2
08/13/2026X00785025-I1Open ↗
08/13/2026X00785025-P1Open ↗
▸BISBPP: STREET TREES SITE PLAN1
12/19/2022240334321Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026X00785025-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X00785025-I1Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
12/02/2008210081392Open ↗
▸Inspections & Test Reports3
▸BISSOIL REPORT1
12/30/2015220151886Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026X00785025-S2Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026X00785025-S2Open ↗
▸Approvals, Objections & Sign-offs15
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter12
08/13/2026X00785025-S6Open ↗
08/13/2026X00785025-I1Open ↗
08/13/2026X08023392-I1Open ↗
Showing 3 of 12 on file for this type
▸BISADMINISTRATIVE OBJECTIONS1
12/11/2008210081392Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
12/23/2020220151886Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
09/18/2017220151886Open ↗
▸Filing & Intake Forms8
▸BISEFILING COVER SHEET4
06/14/2018220653889Open ↗
04/14/2017220151886Open ↗
12/30/2015220151886Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION2
01/20/2023240334321Open ↗
12/23/2019220151886Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
08/26/2022240334321Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
08/26/2022240334321Open ↗
▸Other Documents10
▸BISBPP - SUPPORTING DOCUMENTATION2
08/26/2022240334321Open ↗
08/26/2022240334321Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026X00785025-I1Open ↗
08/13/2026X00785025-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026X00785025-I1Open ↗
08/13/2026X00785025-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/23/2026X00785025-I1Open ↗
08/15/2026X00785025-P1Open ↗
▸BISBPP: TOPOGRAPHIC SURVEY1
12/19/2022240334321Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026X00785025-S1Open ↗