← Back
STATEN ISLAND
1055 Hylan Lh Condominium
1055 HYLAN BOULEVARD · BIN 5047391
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
0 Open ViolationsFDNY Report ↗
Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionCivilGeneral
Permit Issued — active, not yet Signed-off
Roof2p · 1 filing · 3 docs
Floor 1Under Construction29p · 1 filing · 20 docs
CellarUnder Construction34p · 3 filings · 20 docs
Sub-CellarUnder Construction25p · 1 filing · 20 docs
1 job · most recent 10/21/2025
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
10/21/2025Permit IssuedMETRO BUILDERS GROUP LLCAir Conditioning Systems
Cooling
Mitsubishi Electric MXZ-2C20NA2-U1 18,000 BTU · Split System ×1
MXZ-3C30NA2-U1 28,400 BTU · Condensing Unit ×1
PUMY-P60NKMU 60,000 BTU · Vrf Outdoor ×1
Carrier 48FCEA06 2,000 CFM · Fan Coil Indoor ×6
48TCED08 3,400 CFM · Fan Coil Indoor ×2
48TCED09 3,000 CFM · Fan Coil Indoor ×2
1 job · most recent 10/21/2025
Sprinkler System
FiledStatusContractorScope
10/21/2025Signed-offTARGET PIPING NY LLCSprinkler System
1 job · most recent 10/21/2025
Gas Water/Sanitary
FiledStatusContractorScope
10/21/2025Signed-offB&B MECH PLBG & HTG LLCGas, Water/Sanitary
5 jobs · most recent 05/27/2026
General Wiring
FiledStatusContractorScope
05/27/2026CompleteMARTINEZ ELECTRICAL CONT2 meters, 1 new_meters
05/14/2026CompleteBINDER ELT'L SERVICE CORP—
12/17/2023CompleteBINDER ELT'L SERVICE CORPGeneral Wiring
10/01/2023CancelledCAPUTEK ELEC'L SERVICES,—
03/10/2022CompleteBINDER ELT'L SERVICE CORP—
1 job · most recent 10/21/2025
Concrete
FiledStatusContractorScope
10/21/2025Signed-offB&B MECH PLBG & HTG LLCConcrete
Building Lifecycle
All (188)Filed (30)Permit Issued (17)Signed Off (10)Violation (9)Inspection (12)Objection (80)Special Inspection (30)
04/27/2026
Signed off — Alteration
Modification of existing Verizon site on the roof. Replace 3 antennas and 4 RRH units. Install 6 antennas, 2 RRH units, and 2 GPS units. Install 3 cabinets on new platform on roof.
S00872900-I1
11/05/2025
Special inspection requirement — Protection of exposed foundation insulation
ELIAS RASABI
11/05/2025
Special inspection requirement — Subgrade Inspections
ELIAS RASABI
11/05/2025
Special inspection requirement — Metering
ELIAS RASABI
11/05/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ELIAS RASABI
11/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ELIAS RASABI
11/05/2025
Special inspection requirement — Insulation placement and R values
ELIAS RASABI
11/05/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
ELIAS RASABI
11/05/2025
Special inspection requirement — Exterior lighting power
ELIAS RASABI
11/05/2025
Special inspection requirement — Fenestration air leakage
ELIAS RASABI
11/05/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Soorjbally Harilall
11/05/2025
Special inspection requirement — Fenestration areas
ELIAS RASABI
11/05/2025
Special inspection requirement — Concrete - Cast-In-Place
ELIAS RASABI
11/05/2025
Special inspection requirement — Sprayed fire-resistant materials
ELIAS RASABI
11/05/2025
Special inspection requirement — Energy Code Compliance Inspections
ELIAS RASABI
11/05/2025
Special inspection requirement — Maintenance information
ELIAS RASABI
11/05/2025
Special inspection requirement — Lighting controls
ELIAS RASABI
11/05/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
ELIAS RASABI
11/05/2025
Special inspection requirement — Interior lighting power
ELIAS RASABI
10/21/2025
Filed — Alteration CO
Dev Hub consultation 6/28/21 assign to Development HUB. Job filed herewith to convert an existing two story building into a community facility - homeless shelter.
S00534878-B2
10/16/2025
Special inspection requirement — Maintenance information
ELIAS RASABI
10/16/2025
Special inspection requirement — Interior lighting power
ELIAS RASABI
10/16/2025
Special inspection requirement — Lighting controls
ELIAS RASABI
10/16/2025
Special inspection requirement — Subgrade Inspections
ELIAS RASABI
10/16/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Soorjbally Harilall
10/16/2025
Special inspection requirement — Fenestration areas
ELIAS RASABI
10/16/2025
Special inspection requirement — Concrete - Cast-In-Place
ELIAS RASABI
10/16/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ELIAS RASABI
10/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ELIAS RASABI
10/16/2025
Special inspection requirement — Energy Code Compliance Inspections
ELIAS RASABI
10/16/2025
Special inspection requirement — Sprayed fire-resistant materials
ELIAS RASABI
10/16/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
ELIAS RASABI
08/28/2025
Permit issued — Antenna
S00872900-I1-AN
06/10/2025
Objection resolved — Addressed
06/10/2025
Objection resolved — Addressed
06/10/2025
Objection resolved — Addressed
06/10/2025
Objection resolved — Addressed
06/04/2025
Objection raised — Admin
06/04/2025
Objection raised — Scope
06/04/2025
Objection raised — Inspections
06/04/2025
Objection raised — Scope
05/20/2025
Filed — Alteration
Modification of existing Verizon site on the roof. Replace 3 antennas and 4 RRH units. Install 6 antennas, 2 RRH units, and 2 GPS units. Install 3 cabinets on new platform on roof.
S00872900-I1
04/28/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/01/2025
Filed — Alteration CO
Dev Hub consultation 6/28/21 assign to Development HUB. Job filed herewith to convert an existing two story building into a community facility - homeless shelter.
S00534878-B1
12/09/2024
Objection resolved — Addressed
10/23/2024
Objection raised — Other
10/16/2024
Filed — Alteration CO
Dev Hub consultation 6/28/21 assign to Development HUB. Job filed herewith to convert an existing two story building into a community facility - homeless shelter.
S00534878-A9
10/08/2024
Signed off — Alteration
S01055734-I1
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/18/2024
Permit issued — General Construction
S01055734-I1-GC
06/04/2024
Objection raised — Other
06/04/2024
Objection resolved — Addressed
05/29/2024
Filed — Alteration
S01055734-I1
05/10/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/01/2024
Filed — Alteration CO
Dev Hub consultation 6/28/21 assign to Development HUB. Job filed herewith to convert an existing two story building into a community facility - homeless shelter.
S00534878-A8
01/29/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/10/2024
Signed off — Alteration CO
Dev Hub consultation 6/28/21 assign to Development HUB. Job filed herewith to convert an existing two story building into a community facility - homeless shelter.
S00534878-S1
01/08/2024
Filed — Alteration CO
Dev Hub consultation 6/28/21 assign to Development HUB. Job filed herewith to convert an existing two story building into a community facility - homeless shelter.
S00534878-A7
12/25/2023
Filed — Alteration CO
Dev Hub consultation 6/28/21 assign to Development HUB. Job filed herewith to convert an existing two story building into a community facility - homeless shelter.
S00534878-A6
Latest 60 of 188 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
1055 HYLAN OFFICES LL503/22/2026
1055 PARTNERS403/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PDG BUILDING CONSULTANTS LLC LLC5803/21/2026
CONSTRUCTION PERMIT SERVICES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
METRO BUILDERS GROUP LLCGeneral Contractor2506/28/2026
SASENARINE PERSAUDElectrical103/21/2026
TARGET PIPING NY LLCFire Protection106/28/2026
E.T. VANDERBECK INCGeneral Contractor104/09/2026
B&B MECH PLBG & HTG LLCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CITY-WIDE TESTING INC4162510/21/2025
KMB DESIGN GROUP, LLC513105/20/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWAntennaSigned-offE.T. VANDERBECK INC08/28/2025
DOB NOWGeneral ConstructionSigned-offMETRO BUILDERS GROUP LLC07/18/2024
DOB NOWBoiler EquipmentSigned-offJACK PICCINI, INC11/13/2023
DOB NOWMechanical SystemsSigned-offMETRO BUILDERS GROUP LLC11/08/2023
DOB NOWSprinklersSigned-offTARGET PIPING NY LLC06/02/2023
DOB NOWPlumbingSigned-offTARGET PIPING NY LLC06/02/2023
DOB NOWGeneral ConstructionPermit IssuedMETRO BUILDERS GROUP LLC04/24/2023
DOB NOWStructuralSigned-offMETRO BUILDERS GROUP LLC04/24/2023
DOB NOWMechanical SystemsSigned-offMETRO BUILDERS GROUP LLC12/02/2022
DOB NOWGeneral ConstructionPermit IssuedMETRO BUILDERS GROUP LLC12/01/2022
DOB NOWConstruction FenceSigned-offMETRO BUILDERS GROUP LLC11/30/2022
DOB NOWFoundationSigned-offMETRO BUILDERS GROUP LLC11/30/2022
DOB NOWFoundationSigned-offMETRO BUILDERS GROUP LLC08/18/2022
DOB NOWGeneral ConstructionPermit IssuedMETRO BUILDERS GROUP LLC05/03/2022
DOB NOWConstruction FenceSigned-offMETRO BUILDERS GROUP LLC04/27/2022
DOB NOWGeneral ConstructionPermit IssuedMETRO BUILDERS GROUP LLC02/16/2022
DOB NOWConstruction FenceSigned-offMETRO BUILDERS GROUP LLC12/29/2021
BISOTISSUEDSQUAN CONSTRUCTION SERVIC11/25/2015
BISOTISSUEDSQUAN CONSTRUCTION SERVIC11/25/2015
BISMHISSUEDA.E.H BUILDERS CORP06/19/2008
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
04/28/2025Pass-Final CND-Occupancy InspectionPassView ↗
05/10/2024Pass-Final CND-Occupancy InspectionPassView ↗
01/29/2024Pass-Final CND-Occupancy InspectionPassView ↗
12/11/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/11/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
12/11/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/11/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
12/06/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
12/04/2023Pass-Final Boiler Equipment InspectionPassView ↗
10/13/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
10/05/2023Fail-Final General Construction Non-Directive 14FailView ↗
07/26/2023Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
11/05/2025Lighting controlsELIAS RASABIenergy_progress
11/05/2025Subgrade InspectionsELIAS RASABIspecial
11/05/2025Concrete - Cast-In-PlaceELIAS RASABIspecial
11/05/2025Subsurface Investigations (Borings/Test Pits)Soorjbally Harilallspecial
11/05/2025Structural Stability – Alterations of existing buildingsELIAS RASABIspecial
11/05/2025Fire-Resistant Penetrations and JointsELIAS RASABIspecial
11/05/2025Sprayed fire-resistant materialsELIAS RASABIspecial
11/05/2025Energy Code Compliance InspectionsELIAS RASABIprogress
11/05/2025Insulation placement and R valuesELIAS RASABIenergy_progress
11/05/2025Maintenance informationELIAS RASABIenergy_progress
11/05/2025Fenestration areasELIAS RASABIenergy_progress
11/05/2025Protection of exposed foundation insulationELIAS RASABIenergy_progress
11/05/2025HVAC-R and service water piping design and insulationELIAS RASABIenergy_progress
11/05/2025Fenestration air leakageELIAS RASABIenergy_progress
11/05/2025MeteringELIAS RASABIenergy_progress
11/05/2025Exterior lighting powerELIAS RASABIenergy_progress
11/05/2025Interior lighting powerELIAS RASABIenergy_progress
11/05/2025Fenestration and door U-factor and product ratingsELIAS RASABIenergy_progress
10/16/2025Fire-Resistant Penetrations and JointsELIAS RASABIspecial
10/16/2025Insulation placement and R valuesELIAS RASABIenergy_progress
10/16/2025Exterior lighting powerELIAS RASABIenergy_progress
10/16/2025MeteringELIAS RASABIenergy_progress
10/16/2025Fenestration air leakageELIAS RASABIenergy_progress
10/16/2025HVAC-R and service water piping design and insulationELIAS RASABIenergy_progress
10/16/2025Protection of exposed foundation insulationELIAS RASABIenergy_progress
Latest 25 of 150.
▾Documents — 275 on file (BIS + DOB NOW)
▸Plans & Drawings30
▸DOB NOWPlans/Sketch30
08/24/2026S00653070-I1Request digital key ↗
08/22/2026S00946435-I1Request digital key ↗
08/22/2026S00946482-I1Request digital key ↗
Showing 3 of 30 on file for this type
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION5
07/15/2024520468663Open ↗
07/09/2024540263631Open ↗
10/29/2015520253056Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION3
11/30/2015520255321Open ↗
11/30/2015520253056Open ↗
06/19/2008510043908Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
08/14/2025540263631Open ↗
▸Zoning, Tax Lot & Property Records10
▸DOB NOWZD1: DOB Zoning Diagram8
08/13/2026S00534878-I1Open ↗
08/13/2026S00534878-P2Open ↗
08/13/2026S00534878-A4Open ↗
Showing 3 of 8 on file for this type
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
08/01/2024520468663Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00534878-I1Open ↗
▸Seals & Professional Certifications107
▸DOB NOWProgress Inspector Seal & Signature39
09/27/2026S00534878-A7Open ↗
09/27/2026S00534878-A7Open ↗
09/27/2026S00534878-A7Open ↗
Showing 3 of 39 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature30
08/22/2026S00534878-B2Open ↗
08/22/2026S00534878-B1Open ↗
08/22/2026S00534878-A9Open ↗
Showing 3 of 30 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature26
09/27/2026S00534878-A7Open ↗
09/27/2026S00534878-A7Open ↗
09/23/2026S00946435-I1Open ↗
Showing 3 of 26 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
05/24/2016520253056Open ↗
05/24/2016520255321Open ↗
10/29/2015520253056Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/09/2024540263631Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
06/05/2008510043908Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
07/09/2024540263631Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
06/05/2008510043908Open ↗
▸Trade Schedules & Equipment10
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)8
08/13/2026S00534878-A8Open ↗
08/13/2026S00534878-A9Open ↗
08/13/2026S00534878-P2Open ↗
Showing 3 of 8 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT1
08/14/2008510043908Open ↗
▸BISEQUIPMENT USE PERMITS1
08/14/2008510043908Open ↗
▸Safety & Tenant Protection8
▸DOB NOWStreet Tree Checklist8
08/13/2026S00534878-A8Open ↗
08/13/2026S00534878-A7Open ↗
08/13/2026S00534878-A9Open ↗
Showing 3 of 8 on file for this type
▸Environmental & Asbestos29
▸DOB NOWDEP ACP-5: Asbestos Assessment Report26
08/22/2026S00534878-B2Open ↗
08/22/2026S00534878-B1Open ↗
08/22/2026S00534878-A9Open ↗
Showing 3 of 26 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
10/29/2015520255321Open ↗
10/29/2015520253056Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
06/05/2008510043908Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
05/24/2016520253056Open ↗
05/24/2016520255321Open ↗
10/29/2015520253056Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
05/24/2016520253056Open ↗
05/24/2016520255321Open ↗
▸Inspections & Test Reports11
▸DOB NOWSOIL REPORT8
08/13/2026S00534878-I1Open ↗
08/13/2026S00534878-A8Open ↗
08/13/2026S00534878-A9Open ↗
Showing 3 of 8 on file for this type
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
08/14/2025540263631Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026S00534878-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00534878-I1Open ↗
▸Approvals, Objections & Sign-offs8
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
05/24/2016520255321Open ↗
05/24/2016520253056Open ↗
07/30/2008510043908Open ↗
▸BISADMINISTRATIVE OBJECTIONS3
10/29/2015520255321Open ↗
10/29/2015520253056Open ↗
06/05/2008510043908Open ↗
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
08/14/2025540263631Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
08/01/2024520468663Open ↗
▸Cost, Insurance & Ownership8
▸BISCOST AFFIDAVIT6
05/24/2016520253056Open ↗
05/24/2016520255321Open ↗
10/29/2015520253056Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026S00534878-I1Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026S00534878-I1Open ↗
▸Filing & Intake Forms7
▸BISEFILING COVER SHEET4
07/15/2024520468663Open ↗
10/29/2015520253056Open ↗
10/29/2015520255321Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION2
08/14/2025540263631Open ↗
01/25/2016520253056Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
07/09/2024540263631Open ↗
▸Other Documents32
▸DOB NOWPlot Diagram10
08/13/2026S00534878-I1Open ↗
08/13/2026S00534878-A4Open ↗
08/13/2026S00534878-P2Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSite Survey: Initial8
08/13/2026S00534878-I1Open ↗
08/13/2026S00534878-P2Open ↗
08/13/2026S00534878-A4Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION2
08/14/2025540263631Open ↗
08/14/2025540263631Open ↗
▸BISVERIFY DOB PLAN NAMING STANDARD IS MET1
08/01/2024520468663Open ↗
▸BISBPP - DOT Builders Pavement Unit Waiver Request Form1
08/14/2025540263631Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
08/01/2024520468663Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026S00534878-I1Open ↗