| Owner | Filings | Most Recent |
|---|---|---|
| JERRICK ASSOCIATES | 7 | 03/22/2026 |
| SAFETECH ENTERPRISES | 7 | 03/22/2026 |
| 1055 LEXINGTON AVE | 6 | 03/21/2026 |
| 1055 LEXINGTON AVE LLC GREENPOIN | 3 | 03/21/2026 |
| SOLEIL MANAGEMENT | 2 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| EP ENGINEERING LLC | 3 | 07/27/2026 |
| ENV ARCHITECTS, DPC | 2 | 06/11/2026 |
| ASR ENGINEERING PC | 1 | 04/18/2025 |
| PAUL PERDEK, PROF. ENG. PLLC | 1 | 07/08/2024 |
| ALTAGRACIA ESTHER MARTINEZ, R.A. | 1 | 01/08/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| MUNICIPAL BUILDING CONSULTANTS | 1 | 03/21/2026 |
| ADVANCED BUILDERS SERVICES | 1 | 03/21/2026 |
| AE DESIGN SOLUTION | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| SAFETECH ENTERPRISES CORP | General Contractor | 6 | 03/21/2026 |
| GREGORY PAPANTONIOU | Electrical | 2 | 03/21/2026 |
| 5 POINTS REHAB LLC | General Contractor | 2 | 07/08/2026 |
| JERRICK ASSOCIATES INC | General Contractor | 2 | 03/21/2026 |
| RICHARD NEU | Electrical | 1 | 03/21/2026 |
| NY PLUMBING & HEATING COR | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| EP INSPECTIONS AND COMMIS | 7079 | 5 | 07/27/2026 |
| RICHARD H. BALSER ENGINEE | 3028 | 1 | 01/08/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | NY PLUMBING & HEATING COR | 05/12/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | 5 POINTS REHAB LLC | 05/08/2026 |
| DOB NOW | General Construction | Permit Issued | 5 POINTS REHAB LLC | 05/08/2026 |
| DOB NOW | Sidewalk Shed | Permit Issued | SAFETECH ENTERPRISES CORP | 04/18/2025 |
| DOB NOW | Supported Scaffold | Permit Issued | SAFETECH ENTERPRISES CORP | 04/18/2025 |
| DOB NOW | Sidewalk Shed | Signed-off | GE 2A CONSTRUCTION | 07/08/2024 |
| BIS | EQ | ISSUED | JERRICK ASSOCIATES INC | 08/26/2014 |
| BIS | FP | ISSUED | NY FIRE LLC | 03/14/2011 |
| BIS | MH | ISSUED | RETCON MECHANICAL CORP | 12/21/2010 |
| BIS | PL | ISSUED | SAFETY PLMBG & HTG LLC | 12/06/2010 |
| BIS | EQ | ISSUED | JERRICK ASSOCIATES INC | 03/26/2010 |
| BIS | OT | ISSUED | BULADO GENERAL CONTRACTOR | 03/15/2010 |
| BIS | PL | ISSUED | WILLIAM J KENNEDY PLBG INC | 11/13/2006 |
| BIS | MH | ISSUED | KATSELNIK & KATSELNIK GRP | 08/21/2006 |
| BIS | OT | ISSUED | KATSELNIK & KATSELNIK GRP | 08/21/2006 |
| BIS | OT | ISSUED | KATSELNIK & KATSELNIK GRP | 07/19/2006 |
| BIS | FP | ISSUED | ALLIED FIRE CONTROL SERVICES INC | 07/15/1992 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/27/2026 | Permit Issued | 5 POINTS REHAB LLC | Heating and Air Conditioning Systems | Heat / Cool Mitsubishi Electric MXZ-SM96TAM 108,000 BTU · Heat Pump Outdoor ×1 PEFY-P96NMHSU-E 2,900 CFM · Vrf Indoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/27/2026 | Signed-off | NY PLUMBING & HEATING COR | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/09/2026 | Permit Issued | EVS ELECTRIC CORP | General Wiring |
| 04/19/2025 | Permit Issued | RICHARD NEU | — |
| 09/04/2024 | Complete | BOROWIDE ELECT'L CONTR'S | — |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/23/2026 | Fire-Resistant Penetrations and Joints | EVAN PARGANOS | special |
| 07/23/2026 | HVAC-R and service water heating system controls | EVAN PARGANOS | energy_progress |
| 07/23/2026 | HVAC-R and service water heating equipment | EVAN PARGANOS | energy_progress |
| 07/23/2026 | Shutoff dampers | EVAN PARGANOS | energy_progress |
| 07/23/2026 | HVAC-R and service water piping design and insulation | EVAN PARGANOS | energy_progress |
| 07/23/2026 | Maintenance information | EVAN PARGANOS | energy_progress |
| 07/23/2026 | Duct leakage testing, insulation and design | EVAN PARGANOS | energy_progress |
| 07/23/2026 | Final | EVAN PARGANOS | progress |
| 07/23/2026 | Tenant Protection Plan Compliance | EVAN PARGANOS | special |
| 07/23/2026 | Mechanical Systems | EVAN PARGANOS | special |
| 06/11/2026 | Final | EVAN PARGANOS | progress |
| 06/11/2026 | Fire-Resistant Penetrations and Joints | EVAN PARGANOS | special |
| 06/11/2026 | Tenant Protection Plan Compliance | EVAN PARGANOS | special |
| 04/30/2026 | HVAC-R and service water heating system controls | EVAN PARGANOS | energy_progress |
| 04/30/2026 | Fire-Resistant Penetrations and Joints | EVAN PARGANOS | special |
| 04/30/2026 | Post-installed Anchors | EVAN PARGANOS | special |
| 04/30/2026 | HVAC-R and service water piping design and insulation | EVAN PARGANOS | energy_progress |
| 04/30/2026 | HVAC-R and service water heating equipment | EVAN PARGANOS | energy_progress |
| 04/30/2026 | Maintenance information | EVAN PARGANOS | energy_progress |
| 01/04/2024 | Tenant Protection Plan Compliance | — | special |
| 10/24/2023 | Mechanical Systems | Balser Richard | special |
| 10/24/2023 | Electrical motors and elevators | Altagracia Martinez | energy_progress |
| 10/24/2023 | Maintenance information | Altagracia Martinez | energy_progress |
| 10/24/2023 | HVAC-R and service water heating equipment | Altagracia Martinez | energy_progress |
| 10/24/2023 | HVAC-R and service water heating system controls | Altagracia Martinez | energy_progress |