← Back
Four families
1055 SUMMIT AVENUE
BRONX · BIN 2115017
💬 Discuss this project
2006Year Built
3Stories
C3Building Class
R7-1Zoning
4,429 sfGross Floor Area
4Units
Rent Stabilized17 Open Violations ▸
Four families · Owner of record: SUMMIT PROPERTY GARDENS 2 LLC · 1,418 sf lot · 3.12 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalGeneral
Roof12p · 1 filing · 20 docs
Floor 310p · 1 filing · 20 docs
Floor 29p · 1 filing · 20 docs
Floor 19p · 1 filing · 20 docs
Cellar17p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SUMMIT PROPERTY GARDENS 2 LLC703/22/2026
KINGS COLLEGE REAL ESTATE503/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/07/2016$751K—— → —$170/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADVANCED ENGINEERING & INSPECT. PLL607/14/2025
BAOBAB ARCHITECTS P.C.507/14/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEVM EXPEDITORS1803/21/2026
ELLIPSES DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRECISION BUILD USA INCGeneral Contractor1203/22/2026
PRECISION BUILDERS USAGeneral Contractor303/21/2026
VILLAGE P & H NY INCFire Protection107/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE2050607/14/2025
Building Lifecycle
All (159)Filed (11)Permit Issued (5)Signed Off (3)Violation (60)Inspection (10)Objection (40)Special Inspection (30)
07/14/2026
Violation issued (HPD, open)
C
07/14/2026
Violation issued (HPD, open)
C
07/14/2026
Violation issued (HPD, open)
B
07/29/2025
Signed off — Alteration CO
MECHANICAL APPLICATION HEREBY FILED AS SUBSEQUENT FILING FOR JOB # X00582126.
X00582126-S5
07/21/2025
Special inspection requirement — Interior lighting power
PAUL MARINO
07/21/2025
Special inspection requirement — Exterior lighting power
PAUL MARINO
07/21/2025
Special inspection requirement — Lighting in dwelling units
PAUL MARINO
07/21/2025
Special inspection requirement — Air barrier - visual inspection
PAUL MARINO
07/21/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
PAUL MARINO
07/21/2025
Special inspection requirement — Fenestration areas
PAUL MARINO
07/21/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
07/21/2025
Special inspection requirement — Fenestration air leakage
PAUL MARINO
07/21/2025
Special inspection requirement — Lighting controls
PAUL MARINO
07/14/2025
Filed — Alteration CO
MECHANICAL APPLICATION HEREBY FILED AS SUBSEQUENT FILING FOR JOB # X00582126.
X00582126-P8
07/14/2025
Filed — Alteration CO
MECHANICAL APPLICATION HEREBY FILED AS SUBSEQUENT FILING FOR JOB # X00582126.
X00582126-P7
05/21/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
PAUL MARINO
05/21/2025
Special inspection requirement — Lighting in dwelling units
PAUL MARINO
05/21/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
05/21/2025
Special inspection requirement — Air barrier - visual inspection
PAUL MARINO
05/21/2025
Special inspection requirement — Lighting controls
PAUL MARINO
05/21/2025
Special inspection requirement — Fenestration air leakage
PAUL MARINO
05/21/2025
Special inspection requirement — Interior lighting power
PAUL MARINO
05/21/2025
Special inspection requirement — Exterior lighting power
PAUL MARINO
05/21/2025
Special inspection requirement — Fenestration areas
PAUL MARINO
03/05/2025
Signed off — Alteration CO
MECHANICAL APPLICATION HEREBY FILED AS SUBSEQUENT FILING FOR JOB # X00582126.
X00582126-S2
03/05/2025
Signed off — Alteration CO
MECHANICAL APPLICATION HEREBY FILED AS SUBSEQUENT FILING FOR JOB # X00582126.
X00582126-S3
03/05/2025
Special inspection requirement — HVAC-R and service water heating equipment
03/05/2025
Special inspection requirement — Final
JAMES SCHAEFER
03/05/2025
Special inspection requirement — Seismic Resistance of Plumbing, Mechanical, Fuel Gas, and Electrical Components
PAUL MARINO
03/05/2025
Special inspection requirement — Mechanical Systems
PAUL MARINO
03/05/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
03/05/2025
Special inspection requirement — HVAC-R and service water heating system controls
02/26/2025
Violation issued (HPD, closed)
A
01/23/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/12/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
09/10/2024
Violation issued (HPD, closed)
B
09/10/2024
Violation issued (HPD, open)
B
09/10/2024
Violation issued (HPD, closed)
B
09/10/2024
Violation issued (HPD, closed)
A
01/19/2024
Violation issued (ECB, closed)
Construction
01/02/2024
Violation issued (HPD, closed)
C
01/02/2024
Violation issued (HPD, closed)
B
01/02/2024
Violation issued (HPD, closed)
A
01/02/2024
Violation issued (HPD, closed)
C
01/02/2024
Violation issued (HPD, closed)
C
09/14/2023
Violation issued (HPD, closed)
C
09/14/2023
Violation issued (HPD, open)
C
09/08/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/24/2023
Violation issued (ECB, closed)
Construction
08/24/2023
Violation issued (ECB, closed)
Construction
08/09/2023
Filed — Alteration CO
MECHANICAL APPLICATION HEREBY FILED AS SUBSEQUENT FILING FOR JOB # X00582126.
X00582126-P6
08/08/2023
Special inspection requirement — Sprinkler Systems
PAUL MARINO
08/08/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
08/07/2023
Filed — Alteration CO
MECHANICAL APPLICATION HEREBY FILED AS SUBSEQUENT FILING FOR JOB # X00582126.
X00582126-P5
08/03/2023
Violation issued (ECB, closed)
Unknown
08/03/2023
Violation issued (ECB, closed)
Construction
07/21/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
07/21/2023
Special inspection requirement — Sprinkler Systems
PAUL MARINO
05/05/2023
Permit issued — Mechanical Systems
X00582126-S5-MS
05/04/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
Latest 60 of 159 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offPRECISION BUILD USA INC05/05/2023
DOB NOWGeneral ConstructionPermit IssuedPRECISION BUILD USA INC05/02/2023
DOB NOWSprinklersSigned-offVILLAGE P & H NY INC01/10/2023
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.10/24/2022
DOB NOWGeneral ConstructionPermit IssuedPRECISION BUILDERS USA09/13/2022
BISPLISSUEDA P PLUMBING&HEATING INC02/26/2007
BISEQISSUEDAQUINO GENERAL CONSTRUCTION INC.12/06/2006
BIS—ISSUEDAQUINO GENERAL CONSTRUCTION INC.09/26/2006
BISEQISSUEDAQUINO GENERAL CONSTRUCTION INC.08/01/2006
1 project · most recent 07/14/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/14/2025Signed-offPRECISION BUILD USA INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MSZ-GL06NA. 6,000 BTU · Fan Coil Indoor ×2
MSZ-GL12NA. 12,000 BTU · Fan Coil Indoor ×1
NTXMMX24A132BA. 25,000 BTU · Heat Pump Outdoor ×1
Ventilation
Nutone AEN110. 50 CFM · Exhaust Fan ×1
QTXEN150. 100 CFM · Kitchen Exhaust ×1
1 project · most recent 07/14/2025
Sprinkler System
FiledStatusContractorScope
07/14/2025Signed-offPARAMOUNT SERVICES, LLCSprinkler System
1 project · most recent 07/14/2025
Water/Sanitary
FiledStatusContractorScope
07/14/2025Signed-offAMERICAN STANDARD P&H CORWater/Sanitary
2 projects · most recent 10/25/2023
General Wiring
FiledStatusContractorScope
10/25/2023Permit IssuedTFK ELECTRIC CORPGeneral Wiring
11/16/2022CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
01/23/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/12/2024Fail-Final CND-Occupancy InspectionFailView ↗
09/08/2023Pass-Final CND-Occupancy InspectionPassView ↗
05/04/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/19/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/05/2023Pass-Final CND-Occupancy InspectionPassView ↗
04/03/2023Fail-Final CND-Occupancy InspectionFailView ↗
03/31/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
12/08/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/08/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 58
DateRequirementInspectorRole
07/21/2025Interior lighting powerPAUL MARINOenergy_progress
07/21/2025Exterior lighting powerPAUL MARINOenergy_progress
07/21/2025Lighting in dwelling unitsPAUL MARINOenergy_progress
07/21/2025Air barrier - visual inspectionPAUL MARINOenergy_progress
07/21/2025Fenestration and door U-factor and product ratingsPAUL MARINOenergy_progress
07/21/2025Fenestration areasPAUL MARINOenergy_progress
07/21/2025HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
07/21/2025Fenestration air leakagePAUL MARINOenergy_progress
07/21/2025Lighting controlsPAUL MARINOenergy_progress
05/21/2025Fenestration and door U-factor and product ratingsPAUL MARINOenergy_progress
05/21/2025Lighting in dwelling unitsPAUL MARINOenergy_progress
05/21/2025HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
05/21/2025Air barrier - visual inspectionPAUL MARINOenergy_progress
05/21/2025Lighting controlsPAUL MARINOenergy_progress
05/21/2025Fenestration air leakagePAUL MARINOenergy_progress
05/21/2025Interior lighting powerPAUL MARINOenergy_progress
05/21/2025Exterior lighting powerPAUL MARINOenergy_progress
05/21/2025Fenestration areasPAUL MARINOenergy_progress
03/05/2025HVAC-R and service water heating equipment—energy_progress
03/05/2025FinalJAMES SCHAEFERprogress
03/05/2025Seismic Resistance of Plumbing, Mechanical, Fuel Gas, and Electrical ComponentsPAUL MARINOspecial
03/05/2025Mechanical SystemsPAUL MARINOspecial
03/05/2025HVAC-R and service water piping design and insulation—energy_progress
03/05/2025HVAC-R and service water heating system controls—energy_progress
08/08/2023Sprinkler SystemsPAUL MARINOspecial
Latest 25 of 58.
▾Documents — 108 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/23/2026X00582126-P7Request digital key ↗
08/23/2026X00582126-P1Request digital key ↗
08/23/2026X00582126-P2Request digital key ↗
Showing 3 of 11 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZoning Exhibit form (1-5)3
08/13/2026X00582126-P8Open ↗
08/13/2026X00582126-P6Open ↗
08/13/2026X00582126-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X00582126-I1Open ↗
▸Seals & Professional Certifications66
▸DOB NOWProgress Inspector Seal & Signature47
08/29/2026X00582126-P2Open ↗
08/29/2026X00582126-P2Open ↗
08/29/2026X00582126-P2Open ↗
Showing 3 of 47 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/13/2026X00582126-S5Open ↗
08/13/2026X00582126-P1Open ↗
08/13/2026X00582126-S2Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/28/2026X00582126-S2Open ↗
08/28/2026X00582126-S2Open ↗
08/25/2026X00582126-S3Open ↗
Showing 3 of 8 on file for this type
▸Safety & Tenant Protection8
▸DOB NOWStreet Tree Checklist5
08/13/2026X00582126-P8Open ↗
08/13/2026X00582126-P6Open ↗
08/13/2026X00582126-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X00582126-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026X00582126-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026X00582126-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026X00582126-I1Open ↗
▸Other Documents18
▸DOB NOWDHCR Document12
08/13/2026X00582126-P1Open ↗
08/13/2026X00582126-P7Open ↗
08/13/2026X00582126-P6Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWProperty Ownership Certification5
08/13/2026X00582126-P1Open ↗
08/13/2026X00582126-P2Open ↗
08/13/2026X00582126-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWFinal Survey1
08/13/2026X00582126-I1Open ↗