HPD05/11/2026§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT A43, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/11/2026§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT A43, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/13/2026HMC- §272024 PROVIDE AND MAINTAIN A PURE AND WHOLESOME WATER SUPPLY THAT WAS FOUND DISCOLORED AT HOT WATER FIXTURES IN THE BATHTUB IN THE BATHROOM LOCATED AT APT 65, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'', 2nd FROM SOUTH AT WEST
ECB12/18/2025NOTED: EXP 3, REAR YARD UPPER RETAINING WALL, MISSING STONES W/ VERTICAL CRACKS EXTENDING FULL LENGTH OF THE WALL, & STEP-CRACKS. ADDITIONALLY, BROKEN RAILING, MISSING SECTIONS, LEANING & IN DANGER OF COLLAPSE,$12K due
ECB12/18/2025NOTED: AT EXPOSURE 3 RETAINING WALL, ABOUT 10' (H) X 164' (L), PARTIAL COLLAPSE, WHERE STONE SEVERELY DETERIORATED, MISSING IN SEVERAL LOCATIONS, AND A VERTICAL DISPLACED CRACK ABOUT 5" AT CORNER OF EXP 3 & 4 T$12K due
DOB12/18/2025NOTED: AT EXPOSURE 3 RETAINING WALL, ABOUT 10' (H) X 164' (L), PARTIAL COLLAPSE, WHERE STONE SEVERELY DETERIORATED, MISSING IN SEVERAL LOCATIONS, AND A VERTICAL DISPLACED CRACK ABOUT 5 AT CORNER OF EXP 3 & 4 THE ENTIRE HEIGHT OF WALL, ALL IN DANGER OF FURTHER COLLAPSE, CAUSING AN IMMEDIATE DANGER TO BOTH PUBLIC AND PROPERTY.
ECB09/09/2025OBSERVED 8 GAS-FIRED DRYERS INSTALLED IN BASEMENT, WITHOUT SPRINKLER SYSTEM AS PER 903.2.11.13 BC LAUNDRY DRYING AREAS AN AUTOMATIC SPRINKLER SYSTEM SHALL BE INSTALLED IN SPACES IN WHICH TWO OR MORE CLOTHES DRY$1K due
ECB09/09/2025GAS IS BEING SUPPLIED TO 8 CLOTHES DRYERS FROM METER LABELED DRYERS , GAS VALVES FOR ALL DRYERS ARE OPEN AND ACTIVE . NO PERMIT FOR INSTALLATION FOR PIPING TO LAUNDRY ROOM. THEREFORE NO CERTIFICATION FROM DOB T$2K due
ECB09/09/2025OBSERVED FUTURE CONNECTION ON GAS PIPING INSTALLED FROM GAS METER TO CLOTHES DRYERS IN BASEMENT. FUTURE CONNECTIONS ARE PROHIBITED AS PER FGC 404.15. ALSO OBSERVED DRYER EXHAUST PENETRATING THREW WALL , OPENED$1K due
ECB09/09/2025OBSERVED GAS, WATER AND WASTE PIPING INSTALLED, CONNECTING 8 ACTIVE WASHING MACHINES AND 8 GAS FIRED CLOTHES DRYERS. NO PERMIT ON FILE WITH DOB FOR CREATION OF LAUNDRY ROOM IN BASEMENT/ CELLAR., OBTAIN ALL PERM$1K due
ECB02/25/20251RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103-09(E)(2) AND (5). TO DATE, THE DEPARTMENT HAS NOT RECIEVED A RETAINING WALL CONDITION ASSESS$1K due
ECB02/03/2025CLASS 1: PLUNGER REMOVED FROM DOOR RESTRICTOR RENDERING IT INOPERATIVE. INSTALL PLUNGER & RETEST (CU). CLASS 2: CAR DOOR HAS LARGE GAPS ADJUST DOOR TO REMOVE. BRAILLE TAGS & EVACUATION SIGNS MISSING PROVIDE REQ$1K due
HPD01/04/2025§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
HPD11/11/2024§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT A33, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''A''
HPD07/24/2024§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOOR [COURTYARD TO VESTIBULE] AT 1ST STORY
HPD07/24/2024§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT 1ST FIRE ESCAPE FROM NORTH AT BUILDING FRONT AT 5TH STORY BALCONY
DOB05/02/2024FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
HPD10/23/2023§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOOR
HPD10/20/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT B63, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD10/20/2023§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE KITCHEN LOCATED AT APT B63, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD10/19/2022§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT C33, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD10/19/2022§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT C33, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD09/22/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE AT PUBLIC HALL, 3rd STORY
HPD06/08/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT C43, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
ECB12/02/2022FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, ON THE BACK LEFT SIDE OF THE BUILDING I OBSERVED MULTIPLE CONSTRUCTION BAGS OF DEBRIS AND MATERIALS THAT HAVE NOT BEEN REMOVEDNothing owed — awaiting certificate of correction