← Back
Two family frame
107-01 110 STREET
QUEENS · BIN 4203245
💬 Discuss this project
1930Year Built
2Stories
B2Building Class
R4BZoning
2,252 sfGross Floor Area
2Units
0 Open Violations
Two family frame · 2,335 sf lot · 0.96 FAR built · Flood zone X
Locations of Work
Electrical
Roof1 filing · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/08/2025$975K—— → —$433/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR105/28/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
POWER SURGE ELECTRIC, INCElectrical203/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281105/28/2026
Building Lifecycle
All (13)Filed (1)Permit Issued (1)Violation (4)Special Inspection (7)
08/28/2026
Permit issued — Solar
Q01408224-I1-SL
05/28/2026
Filed — Alteration
Installation of solar panels, rooftop, grid tied, railed, 14 modules, 5.74 KW
Q01408224-I1
05/28/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
05/28/2026
Special inspection requirement — Adhesive-Based Solar Pedestal Bonding Systems
Mina Makar
05/28/2026
Special inspection requirement — Post-installed Anchors
Mina Makar
05/28/2026
Special inspection requirement — Air barrier - visual inspection
Mina Makar
05/27/2026
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
05/27/2026
Special inspection requirement — Final
Mina Makar
05/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
01/13/2025
Violation issued (HPD, closed)
B
01/13/2025
Violation issued (HPD, closed)
B
01/13/2025
Violation issued (HPD, closed)
B
06/30/2005
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedMOMENTUM SOLAR08/28/2026
2 projects · most recent 05/28/2026
General Wiring
FiledStatusContractorScope
05/28/2026CompleteISLAND ELECTRIC CORP—
08/07/2025CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
1 project · most recent 05/28/2026
FiledStatusContractorScope
05/28/2026Permit IssuedMOMENTUM SOLAR14 panels, 5.74 kw, 2,335 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
05/28/2026Structural Stability – Alterations of existing buildingsMina Makarspecial
05/28/2026Adhesive-Based Solar Pedestal Bonding SystemsMina Makarspecial
05/28/2026Post-installed AnchorsMina Makarspecial
05/28/2026Air barrier - visual inspectionMina Makarenergy_progress
05/27/2026Energy Code Compliance InspectionsMina Makarprogress
05/27/2026FinalMina Makarprogress
05/27/2026Fire-Resistant Penetrations and JointsMina Makarspecial
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026Q01408224-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWSpecial Inspector Seal & Signature3
08/25/2026Q01408224-I1Open ↗
08/25/2026Q01408224-I1Open ↗
08/25/2026Q01408224-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026Q01408224-I1Open ↗
08/25/2026Q01408224-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026Q01408224-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/16/2026Q01408224-I1Open ↗