← Back
Primarily 2 family with 1 store or office
107-02 GUY R BREWER BLVD
QUEENS · BIN 4216011
💬 Discuss this project
1920Year Built
2Stories
S2Building Class
R6DZoning
1,822 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: MAO REALTY GROUP LLC · 2,250 sf lot · 0.81 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar1p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MAO REALTY GROUP LLC503/22/2026
MAO RIALTY GROUP, LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/04/2020$605K—— → —$332/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A&B WORLD CONSULTING111/17/2020
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AP ELECTL SER & MAIN INCElectrical103/22/2026
G.M.A. PLUMBING & HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A&B WORLD CONSULTING, INC5704111/17/2020
Building Lifecycle
All (47)Filed (1)Permit Issued (1)Signed Off (1)Violation (41)Special Inspection (3)
06/26/2026
Signed off — Alteration
Replacement of two (2) Navien NCB-240E Condensing Gas Combination Boilers with associated controls and piping.
Q00428511-I1
12/11/2020
Permit issued — Plumbing
Q00428511-I1-PL
11/17/2020
Filed — Alteration
Replacement of two (2) Navien NCB-240E Condensing Gas Combination Boilers with associated controls and piping.
Q00428511-I1
11/16/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Bomstein
11/16/2020
Special inspection requirement — HVAC and service water heating equipment
Alexander Bomstein
11/16/2020
Special inspection requirement — HVAC and service water heating system controls
Alexander Bomstein
03/08/2019
Violation issued (ECB, closed)
Construction
08/10/2016
Violation issued (HPD, closed)
I
08/05/2016
Violation issued (HPD, closed)
C
07/15/2016
Violation issued (HPD, closed)
B
05/13/2016
Violation issued (HPD, closed)
B
05/13/2016
Violation issued (HPD, closed)
B
05/13/2015
Violation issued (HPD, closed)
B
05/13/2015
Violation issued (HPD, closed)
A
02/25/2015
Violation issued (HPD, closed)
B
02/25/2015
Violation issued (HPD, closed)
B
02/25/2015
Violation issued (HPD, closed)
B
02/25/2015
Violation issued (HPD, closed)
B
02/25/2015
Violation issued (HPD, closed)
B
02/25/2015
Violation issued (HPD, closed)
B
02/25/2015
Violation issued (HPD, closed)
B
02/21/2015
Violation issued (HPD, closed)
B
02/21/2015
Violation issued (HPD, closed)
C
02/21/2015
Violation issued (HPD, closed)
C
02/21/2015
Violation issued (HPD, closed)
C
09/29/2011
Violation issued (HPD, closed)
A
09/29/2011
Violation issued (HPD, closed)
B
09/29/2011
Violation issued (HPD, closed)
B
09/29/2011
Violation issued (HPD, closed)
B
09/29/2011
Violation issued (HPD, closed)
B
09/29/2011
Violation issued (HPD, closed)
B
09/29/2011
Violation issued (HPD, closed)
B
09/29/2011
Violation issued (HPD, closed)
B
09/29/2011
Violation issued (HPD, closed)
B
09/29/2011
Violation issued (HPD, closed)
B
09/29/2011
Violation issued (HPD, closed)
B
04/02/2010
Violation issued (HPD, closed)
B
04/02/2010
Violation issued (HPD, closed)
B
04/02/2010
Violation issued (HPD, closed)
B
04/02/2010
Violation issued (HPD, closed)
B
04/02/2010
Violation issued (HPD, closed)
B
07/10/2009
Violation issued (HPD, closed)
B
07/10/2009
Violation issued (HPD, closed)
B
07/10/2009
Violation issued (HPD, closed)
A
07/10/2009
Violation issued (HPD, closed)
A
07/10/2009
Violation issued (HPD, closed)
B
02/16/2008
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offG.M.A. PLUMBING & HEATING12/11/2020
1 project · most recent 11/17/2020
Gas
FiledStatusContractorScope
11/17/2020Signed-offG.M.A. PLUMBING & HEATINGGas
1 project · most recent 08/25/2020
General Wiring
FiledStatusContractorScope
08/25/2020CompleteAP ELECTL SER & MAIN INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
11/16/2020Fire-Resistant Penetrations and JointsAlexander Bomsteinspecial
11/16/2020HVAC and service water heating equipment Alexander Bomsteinenergy_progress
11/16/2020HVAC and service water heating system controls Alexander Bomsteinenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch - Plumbing1
08/27/2026Q00428511-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026Q00428511-I1Open ↗
08/26/2026Q00428511-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q00428511-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q00428511-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q00428511-I1Open ↗