← Back
Two family frame
107-33 132 STREET
QUEENS · BIN 4625699
💬 Discuss this project
1940Year Built
2Stories
B2Building Class
R3-2Zoning
2,268 sfGross Floor Area
2Units
Rent Stabilized9 Open Violations 8 unresolved · 1 paperwork only ▸
Two family frame · Owner of record: 14920 17TH AVENUE LLC · 7,360 sf lot · 0.31 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction9p · 1 filing · 20 docs
Floor 1Under Construction9p · 1 filing · 20 docs
CellarUnder Construction11p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
14920 17TH AVENUE603/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/30/2024$920K—— → —$406/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
D&E BUILD EVERGREEN INC.309/19/2025
PETER CHO ARCHITECTS, PLLC109/19/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METRO DESIGN CONSULTANTS INC803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NCR CONSTRUCTION INCGeneral Contractor204/09/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TRIANGLE INSPECTION & TES7495209/19/2025
Building Lifecycle
All (64)Filed (4)Permit Issued (3)Inspection (5)Objection (22)Special Inspection (30)
06/26/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
04/22/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
04/22/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
04/22/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/22/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/16/2026
Permit issued — Plumbing
Q01261896-S2-PL
03/09/2026
Permit issued — Structural
Q01261896-I1-GC-CX
02/24/2026
Permit issued — Construction Fence
Q01261896-S1-FN
01/22/2026
Objection resolved — Addressed
01/22/2026
Objection resolved — Addressed
01/14/2026
Objection resolved — Addressed
01/14/2026
Objection resolved — Addressed
12/09/2025
Objection resolved — Addressed
12/09/2025
Objection resolved — Addressed
12/09/2025
Objection resolved — Addressed
12/09/2025
Objection resolved — Addressed
12/09/2025
Objection resolved — Addressed
12/09/2025
Objection resolved — Addressed
12/09/2025
Objection resolved — Addressed
10/09/2025
Objection raised — Zoning
10/09/2025
Objection raised — Zoning
10/09/2025
Objection raised — Zoning
10/08/2025
Objection raised — Scope
10/08/2025
Objection raised — Admin
10/06/2025
Objection raised — Zoning
10/06/2025
Objection raised — Structural
10/06/2025
Objection raised — Zoning
10/06/2025
Objection raised — Scope
10/06/2025
Objection raised — Structural
10/06/2025
Objection raised — Admin
09/19/2025
Filed — New Building
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q01261896-I1.
Q01261896-S3
09/19/2025
Filed — New Building
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q01261896-I1.
Q01261896-I1
09/19/2025
Filed — New Building
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q01261896-I1.
Q01261896-S1
09/19/2025
Filed — New Building
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q01261896-I1.
Q01261896-S2
07/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Rajasekhar Sakhamuri
07/26/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Rajasekhar Sakhamuri
07/26/2025
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
07/26/2025
Special inspection requirement — Energy Code Compliance Inspections
Rajasekhar Sakhamuri
07/26/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Rajasekhar Sakhamuri
07/26/2025
Special inspection requirement — HVAC-R and service water heating system controls
Rajasekhar Sakhamuri
07/26/2025
Special inspection requirement — Maintenance information
Rajasekhar Sakhamuri
07/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Structural Steel - Details
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Mechanical Systems
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Energy Code Compliance Inspections
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Fire-Resistance Rated Construction
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Structural Wood Frame
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Final
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Footing and Foundation
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Duct leakage testing, insulation and design
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Metering
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Electric vehicle service equipment requirements
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Concrete - Cast-In-Place
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Air barrier — testing
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Interior lighting power
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Insulation placement and R values
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Maintenance information
Rajasekhar Sakhamuri
07/25/2025
Special inspection requirement — Air barrier - visual inspection
Rajasekhar Sakhamuri
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedINFINITI ESC PLUMBING COR04/16/2026
DOB NOWStructuralPermit IssuedNCR CONSTRUCTION INC03/09/2026
DOB NOWConstruction FencePermit IssuedNCR CONSTRUCTION INC02/24/2026
1 job · most recent 09/19/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/19/2025Permit IssuedNCR CONSTRUCTION INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Cooper & Hunter CH-N60LCU-230VO 60,000 BTU · Condensing Unit ×2
Heating
Cooper & Hunter CH-60AHU 60,000 BTU · Ahu ×2
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×5
Delta Breeze SMT150 150 CFM · Exhaust Fan ×2
1 job · most recent 09/19/2025
Storm Water/Sanitary
FiledStatusContractorScope
09/19/2025Permit IssuedINFINITI ESC PLUMBING CORStorm, Water/Sanitary
1 job · most recent 06/17/2026
General Wiring
FiledStatusContractorScope
06/17/2026Permit IssuedMETROPOLITAN ELEC OF NY IGeneral Wiring
1 job · most recent 09/19/2025
Steel Wood
FiledStatusContractorScope
09/19/2025Permit IssuedINFINITI ESC PLUMBING CORSteel, Wood
1 job · most recent 09/19/2025
Fence
FiledStatusContractorScope
09/19/2025Permit IssuedINFINITI ESC PLUMBING CORFence
1 job · most recent 09/19/2025
Earthwork
FiledStatusContractorScope
09/19/2025Permit IssuedINFINITI ESC PLUMBING COREarthwork
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
06/26/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/22/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
04/22/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/22/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/22/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 40
DateRequirementInspectorRole
07/26/2025Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
07/26/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationRajasekhar Sakhamurispecial
07/26/2025Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
07/26/2025Energy Code Compliance InspectionsRajasekhar Sakhamuriprogress
07/26/2025HVAC-R and service water piping design and insulationRajasekhar Sakhamurienergy_progress
07/26/2025HVAC-R and service water heating system controlsRajasekhar Sakhamurienergy_progress
07/26/2025Maintenance informationRajasekhar Sakhamurienergy_progress
07/26/2025HVAC-R and service water heating equipmentRajasekhar Sakhamurienergy_progress
07/25/2025Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
07/25/2025Structural Steel - DetailsRajasekhar Sakhamurispecial
07/25/2025Mechanical SystemsRajasekhar Sakhamurispecial
07/25/2025Energy Code Compliance InspectionsRajasekhar Sakhamuriprogress
07/25/2025Fire-Resistance Rated ConstructionRajasekhar Sakhamuriprogress
07/25/2025Structural Wood FrameRajasekhar Sakhamuriprogress
07/25/2025FinalRajasekhar Sakhamuriprogress
07/25/2025Footing and FoundationRajasekhar Sakhamuriprogress
07/25/2025Duct leakage testing, insulation and designRajasekhar Sakhamurienergy_progress
07/25/2025MeteringRajasekhar Sakhamurienergy_progress
07/25/2025Electric vehicle service equipment requirementsRajasekhar Sakhamurienergy_progress
07/25/2025HVAC-R and service water piping design and insulationRajasekhar Sakhamurienergy_progress
07/25/2025Concrete - Cast-In-PlaceRajasekhar Sakhamurispecial
07/25/2025Air barrier — testing Rajasekhar Sakhamurienergy_progress
07/25/2025Interior lighting powerRajasekhar Sakhamurienergy_progress
07/25/2025Insulation placement and R valuesRajasekhar Sakhamurienergy_progress
07/25/2025Maintenance informationRajasekhar Sakhamurienergy_progress
Latest 25 of 40.
▾Documents — 58 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/18/2026Q01261896-S3Request digital key ↗
08/18/2026Q01261896-S2Request digital key ↗
08/18/2026Q01261896-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01261896-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01261896-I1Open ↗
▸Seals & Professional Certifications44
▸DOB NOWProgress Inspector Seal & Signature26
09/28/2026Q01261896-I1Open ↗
09/28/2026Q01261896-I1Open ↗
09/28/2026Q01261896-I1Open ↗
Showing 3 of 26 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature14
09/28/2026Q01261896-I1Open ↗
09/28/2026Q01261896-I1Open ↗
09/28/2026Q01261896-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/18/2026Q01261896-S3Open ↗
08/18/2026Q01261896-S2Open ↗
08/18/2026Q01261896-S1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q01261896-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01261896-I1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01261896-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q01261896-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification1
08/18/2026Q01261896-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01261896-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01261896-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q01261896-I1Open ↗