← Back
Office only, 1 story
107 NORFOLK STREET
MANHATTAN · BIN 1004292
💬 Discuss this project
1920Year Built
1Stories
O1Building Class
R7AZoning
2,500 sfGross Floor Area
1Units
6 Open Violations 0 unresolved · 6 paperwork only ▸FDNY Report ↗
Office only, 1 story · Owner of record: LO-HO, LLC · 2,500 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction47p · 1 filing · 20 docs
Floor 1Under Construction64p · 1 filing · 20 docs
CellarUnder Construction69p · 2 filings · 20 docs
1 job · most recent 07/20/2026
Associated Ducts and Piping Heating and Air Conditioning Systems Others Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/20/2026Permit IssuedDNP BUILDERS LLCAssociated Ducts and Piping, Heating and Air Conditioning Systems, Others, Ventilation Systems
Heat / Cool
Daikin FXDQ24MVJU 24,000 BTU · Vrf Indoor ×12
FXDQ18MVJU 18,000 BTU · Vrf Indoor ×6
FXZQ18MVJU9 18,000 BTU · Vrf Indoor ×6
RXTQ36TAVJU 34,200 BTU · Vrf Outdoor ×6
FXAQ07PVJU 7,500 BTU · Vrf Indoor ×3
FXAQ12PVJU 12,000 BTU · Vrf Indoor ×2
FXDQ12MVJU 12,000 BTU · Vrf Indoor ×3
FXSQ24TAVJU 24,000 BTU · Vrf Indoor ×3
REYQ144XATJA 144,000 BTU · Vrf Outdoor ×3
FTXV09AVJU9 9,000 BTU · Fan Coil Indoor ×1
FTXV12AVJU9 12,000 BTU · Fan Coil Indoor ×1
Ventilation
Greenheck G-095-VG 225 CFM · Exhaust Fan ×6
Captiveaire CAS-HVAC3-I.500-24MF-20T 5,500 CFM · Rooftop Unit ×3
Smog-Hog PSG-11-3 1,200 CFM ×3
Other
Captiveaire KVE 2,300 CFM · Kitchen Exhaust ×6
166-MISC-PSP 1,220 BTU · Makeup Air ×3
A1-D.250-15D 1,220 CFM · Makeup Air ×3
CH 400 BTU · Kitchen Exhaust ×3
USBI15DD-RM 1,525 CFM · Exhaust Fan ×3
USBI18DD-RM 2,300 CFM · Exhaust Fan ×3
Greenheck USF-10-B6 400 BTU · Exhaust Fan ×3
USF-12-B6 1,550 CFM · Exhaust Fan ×3
Halton KVM 1,525 CFM · Kitchen Exhaust ×3
1 job · most recent 07/20/2026
Sprinkler System
FiledStatusContractorScope
07/20/2026Permit IssuedFIVE BORO ASSOCIATES INCSprinkler System
1 job · most recent 07/20/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/20/2026Permit IssuedSOLUTION MECH CONTNG LLCGas, Storm, Water/Sanitary
3 jobs · most recent 12/17/2025
General Wiring
FiledStatusContractorScope
12/17/2025Permit IssuedENNELL GRP ELECTRIC CORP—
12/04/2024Permit IssuedENNELL GRP ELECTRIC CORPGeneral Wiring
01/18/2024Permit IssuedSHELBY ELECTRICAL CORP—
1 job · most recent 07/20/2026
Steel
FiledStatusContractorScope
07/20/2026Permit IssuedDNP BUILDERS LLCSteel
Building Lifecycle
All (112)Filed (18)Permit Issued (17)Signed Off (3)Violation (8)Inspection (8)Objection (28)Special Inspection (30)
08/21/2026
Objection resolved — Resolved
08/13/2026
Objection raised — Other
08/05/2026
Objection resolved — Addressed
08/04/2026
Objection raised — Other
08/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALEXIS SCHLESSINGERMAN
08/04/2026
Special inspection requirement — Post-installed Anchors
ALEXIS SCHLESSINGERMAN
08/04/2026
Special inspection requirement — Sprinkler Systems
ALEXIS SCHLESSINGERMAN
07/20/2026
Filed — Alteration CO
Filed herewith Sprinkler and piping work throughout as per plans filed. Filed in conjunction with Alt CO #M00891488. No change in occupancy, use or egress.
M00891488-A2
07/16/2026
Filed — Alteration CO
Filed herewith Sprinkler and piping work throughout as per plans filed. Filed in conjunction with Alt CO #M00891488. No change in occupancy, use or egress.
M00891488-A4
07/16/2026
Filed — Alteration CO
Filed herewith Sprinkler and piping work throughout as per plans filed. Filed in conjunction with Alt CO #M00891488. No change in occupancy, use or egress.
M00891488-A5
06/18/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
ALEXIS SCHLESSINGERMAN
06/18/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALEXIS SCHLESSINGERMAN
06/18/2026
Special inspection requirement — Energy Code Compliance Inspections
ALEXIS SCHLESSINGERMAN
06/18/2026
Special inspection requirement — HVAC-R and service water heating equipment
ALEXIS SCHLESSINGERMAN
06/18/2026
Special inspection requirement — HVAC-R and service water heating system controls
ALEXIS SCHLESSINGERMAN
06/18/2026
Special inspection requirement — Post-installed Anchors
ALEXIS SCHLESSINGERMAN
06/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALEXIS SCHLESSINGERMAN
06/17/2026
Special inspection requirement — Sprinkler Systems
ALEXIS SCHLESSINGERMAN
06/17/2026
Special inspection requirement — Post-installed Anchors
ALEXIS SCHLESSINGERMAN
06/12/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/04/2026
Permit issued — Mechanical Systems
M00891488-S1-MS
06/04/2026
Permit issued — General Construction
M00891488-I1-GC
04/16/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/24/2026
Permit issued — Mechanical Systems
M00891488-S1-MS
03/24/2026
Permit issued — General Construction
M00891488-I1-GC
03/05/2026
Objection resolved — Addressed
02/09/2026
Objection raised — Cost
02/03/2026
Filed — Alteration CO
Filed herewith Sprinkler and piping work throughout as per plans filed. Filed in conjunction with Alt CO #M00891488. No change in occupancy, use or egress.
M00891488-A1
01/23/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/05/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/26/2025
Permit issued — Plumbing
M00891488-S2-PL
11/26/2025
Permit issued — Sprinklers
M00891488-S3-EW-SP
11/05/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/29/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/21/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
08/21/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/21/2025
Special inspection requirement — Energy Code Compliance Inspections
ALEXIS SCHLESSINGERMAN
08/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALEXIS SCHLESSINGERMAN
08/21/2025
Special inspection requirement — Insulation placement and R values
ALEXIS SCHLESSINGERMAN
08/21/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
ALEXIS SCHLESSINGERMAN
08/21/2025
Special inspection requirement — Air barrier - visual inspection
ALEXIS SCHLESSINGERMAN
08/21/2025
Special inspection requirement — Fenestration areas
ALEXIS SCHLESSINGERMAN
08/21/2025
Special inspection requirement — Protection of exposed foundation insulation
ALEXIS SCHLESSINGERMAN
08/21/2025
Special inspection requirement — Fenestration air leakage
ALEXIS SCHLESSINGERMAN
08/21/2025
Special inspection requirement — Fire-Resistance Rated Construction
ALEXIS SCHLESSINGERMAN
08/14/2025
Objection resolved — Addressed
08/08/2025
Objection resolved — Addressed
08/04/2025
Objection raised — Scope
07/24/2025
Signed off — Alteration CO
Filed herewith Sprinkler and piping work throughout as per plans filed. Filed in conjunction with Alt CO #M00891488. No change in occupancy, use or egress.
M00891488-S5
07/23/2025
Special inspection requirement — Fire-Resistance Rated Construction
ALEXIS SCHLESSINGERMAN
07/23/2025
Special inspection requirement — HVAC-R and service water heating system controls
ALEXIS SCHLESSINGERMAN
07/23/2025
Special inspection requirement — Energy Code Compliance Inspections
ALEXIS SCHLESSINGERMAN
07/23/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
ALEXIS SCHLESSINGERMAN
07/23/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALEXIS SCHLESSINGERMAN
07/23/2025
Special inspection requirement — Duct leakage testing, insulation and design
ALEXIS SCHLESSINGERMAN
07/23/2025
Special inspection requirement — Final
ALEXIS SCHLESSINGERMAN
07/23/2025
Special inspection requirement — Maintenance information
ALEXIS SCHLESSINGERMAN
07/23/2025
Special inspection requirement — Mechanical Systems
ALEXIS SCHLESSINGERMAN
07/02/2025
Filed — Alteration CO
Filed herewith Sprinkler and piping work throughout as per plans filed. Filed in conjunction with Alt CO #M00891488. No change in occupancy, use or egress.
M00891488-P8
06/30/2025
Objection resolved — Addressed
Latest 60 of 112 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WILLIAM GOTTLIEB MANAGEMENT4809/15/2026
KORNDOERFER CONSULTANTS303/22/2026
OWNER OF 107 NORFOLK ST403/22/2026
OWNER OF 107 NORFOLK AVE103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TANG STUDIO ARCHITECT LLC707/20/2026
TSF ENGINEERING, PC907/16/2026
HANSEN ENGINEERING, PC204/09/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.1503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DNP BUILDERS LLCGeneral Contractor1207/08/2026
ELYSIUM CONSTRUCTION INCGeneral Contractor307/08/2026
KUNCZE, JAMESElectrical203/21/2026
VALLARIO, CHRISTOPHERElectrical203/21/2026
FIVE BORO ASSOCIATES INCFire Protection207/08/2026
SOLUTION MECH CONTNG LLCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SOCOTEC ENGINEERING49831407/20/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedDNP BUILDERS LLC06/04/2026
DOB NOWGeneral ConstructionPermit IssuedDNP BUILDERS LLC06/04/2026
DOB NOWMechanical SystemsPermit IssuedDNP BUILDERS LLC03/24/2026
DOB NOWGeneral ConstructionPermit IssuedDNP BUILDERS LLC03/24/2026
DOB NOWPlumbingPermit IssuedSOLUTION MECH CONTNG LLC11/26/2025
DOB NOWSprinklersPermit IssuedFIVE BORO ASSOCIATES INC11/26/2025
DOB NOWStructuralPermit IssuedDNP BUILDERS LLC03/21/2025
DOB NOWGeneral ConstructionPermit IssuedDNP BUILDERS LLC03/21/2025
DOB NOWMechanical SystemsPermit IssuedDNP BUILDERS LLC03/21/2025
DOB NOWConstruction FenceSigned-offDNP BUILDERS LLC03/19/2025
DOB NOWConstruction FenceSigned-offDNP BUILDERS LLC12/04/2024
DOB NOWMechanical SystemsPermit IssuedDNP BUILDERS LLC12/03/2024
DOB NOWSprinklersPermit IssuedFIVE BORO ASSOCIATES INC11/21/2024
DOB NOWPlumbingPermit IssuedSOLUTION MECH CONTNG LLC11/21/2024
DOB NOWGeneral ConstructionPermit IssuedDNP BUILDERS LLC10/17/2024
DOB NOWGeneral ConstructionSigned-offELYSIUM CONSTRUCTION INC12/21/2023
DOB NOWGeneral ConstructionSigned-offELYSIUM CONSTRUCTION INC05/03/2023
BISPLISSUEDQMB PLUMBING & HEATING INC10/19/2012
BISOTISSUEDA & J GENERAL CONST GROUP10/09/2012
BISEQISSUEDA & J GENERAL CONST GROUP10/09/2012
BISOTISSUEDA & J GENERAL CONST GROUP10/09/2012
BISOTISSUEDJEPOL CONSTRUCTION INC01/12/2012
BISOTISSUEDJEPOL CONSTRUCTION INC02/01/2011
BISEQISSUEDINTERSYSTEMS CORPORATION01/18/2011
BIS—ISSUEDH & H BUILDING CONSULTANTS07/07/2003
BISEQISSUEDH.H. BUILDING CONSUL04/27/2001
BIS—ISSUEDH & H BUILDING CONSULTANTS04/25/2001
BIS—ISSUEDYES, WE DO GENERAL CONTRACTORS08/05/1999
BISPLISSUEDALJER PLBG & HTG CORP03/11/1998
BISOTISSUEDYES WE DO02/23/1998
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
06/12/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/16/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/23/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/05/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/05/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/29/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/21/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
08/21/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 88
DateRequirementInspectorRole
08/04/2026Sprinkler SystemsALEXIS SCHLESSINGERMANspecial
08/04/2026Post-installed AnchorsALEXIS SCHLESSINGERMANspecial
08/04/2026Fire-Resistant Penetrations and JointsALEXIS SCHLESSINGERMANspecial
06/18/2026Fire-Resistant Penetrations and JointsALEXIS SCHLESSINGERMANspecial
06/18/2026HVAC-R and service water piping design and insulationALEXIS SCHLESSINGERMANenergy_progress
06/18/2026Energy Code Compliance InspectionsALEXIS SCHLESSINGERMANprogress
06/18/2026Post-installed AnchorsALEXIS SCHLESSINGERMANspecial
06/18/2026HVAC-R and service water heating system controlsALEXIS SCHLESSINGERMANenergy_progress
06/18/2026HVAC-R and service water heating equipmentALEXIS SCHLESSINGERMANenergy_progress
06/17/2026Post-installed AnchorsALEXIS SCHLESSINGERMANspecial
06/17/2026Fire-Resistant Penetrations and JointsALEXIS SCHLESSINGERMANspecial
06/17/2026Sprinkler SystemsALEXIS SCHLESSINGERMANspecial
08/21/2025Insulation placement and R valuesALEXIS SCHLESSINGERMANenergy_progress
08/21/2025Fire-Resistant Penetrations and JointsALEXIS SCHLESSINGERMANspecial
08/21/2025Energy Code Compliance InspectionsALEXIS SCHLESSINGERMANprogress
08/21/2025Fire-Resistance Rated ConstructionALEXIS SCHLESSINGERMANprogress
08/21/2025Fenestration air leakageALEXIS SCHLESSINGERMANenergy_progress
08/21/2025Protection of exposed foundation insulationALEXIS SCHLESSINGERMANenergy_progress
08/21/2025Fenestration areasALEXIS SCHLESSINGERMANenergy_progress
08/21/2025Air barrier - visual inspectionALEXIS SCHLESSINGERMANenergy_progress
08/21/2025Fenestration and door U-factor and product ratingsALEXIS SCHLESSINGERMANenergy_progress
07/23/2025Mechanical SystemsALEXIS SCHLESSINGERMANspecial
07/23/2025Chimneys and ventsALEXIS SCHLESSINGERMANspecial
07/23/2025HVAC-R and service water piping design and insulationALEXIS SCHLESSINGERMANenergy_progress
07/23/2025Duct leakage testing, insulation and designALEXIS SCHLESSINGERMANenergy_progress
Latest 25 of 88.
▾Documents — 149 on file (BIS + DOB NOW)
▸Plans & Drawings21
▸DOB NOWPlans/Sketch21
08/31/2026M00858465-I1Request digital key ↗
08/29/2026M00927253-I1Request digital key ↗
08/23/2026M00891488-P8Request digital key ↗
Showing 3 of 21 on file for this type
▸Applications & Permits13
▸BISWORK PERMIT APPLICATION7
10/22/2012120964821Open ↗
10/11/2012120964821Open ↗
10/11/2012120964821Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION6
10/09/2012121347818Open ↗
08/15/2012120964821Open ↗
03/20/2012120964821Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications55
▸DOB NOWDPL-1: Design Professional Seal & Signature19
08/29/2026M00927253-I1Open ↗
08/23/2026M00891488-P5Open ↗
08/23/2026M00891488-P4Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWProgress Inspector Seal & Signature17
09/28/2026M00891488-P8Open ↗
09/28/2026M00891488-P8Open ↗
09/01/2026M00891488-P9Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
09/28/2026M00891488-P8Open ↗
09/01/2026M00891488-A4Open ↗
09/01/2026M00891488-P9Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
03/20/2012120964821Open ↗
02/21/2012120964821Open ↗
10/15/2010120496061Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
01/26/2011120579720Open ↗
10/15/2010120496061Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
01/26/2011120579720Open ↗
10/15/2010120496061Open ↗
▸Trade Schedules & Equipment3
▸BISSELF-CERT PLUMBING NOTICE2
12/07/2012120964821Open ↗
11/23/2012120964821Open ↗
▸BISSCHEDULE B - PLUMBING1
02/21/2012120964821Open ↗
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist6
08/23/2026M00891488-P7Open ↗
08/23/2026M00891488-P1Open ↗
08/23/2026M00891488-S4Open ↗
Showing 3 of 6 on file for this type
▸BISSRO MD ANTI-HARASSMENT CHECKLIST1
01/26/2011120579720Open ↗
▸Environmental & Asbestos33
▸DOB NOWDEP ACP-5: Asbestos Assessment Report19
08/29/2026M00927253-I1Open ↗
08/23/2026M00891488-P7Open ↗
08/23/2026M00891488-P5Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWOER: Notice to Proceed9
08/23/2026M00891488-P7Open ↗
08/23/2026M00891488-P4Open ↗
08/23/2026M00891488-P1Open ↗
Showing 3 of 9 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
02/21/2012120964821Open ↗
02/21/2012120964821Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP 20-21-5)1
02/03/2011120496061Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
01/26/2011120579720Open ↗
▸DOB NOWOER: Notice of Satisfaction1
08/13/2026M00927253-I1Open ↗
▸Energy Compliance2
▸BISTR8: Energy Code Progress Inspections1
10/04/2012120964821Open ↗
▸BISTECHNICAL REPORT: ENERGY1
02/21/2012120964821Open ↗
▸Approvals, Objections & Sign-offs3
▸BISADMINISTRATIVE OBJECTIONS3
02/21/2012120964821Open ↗
01/26/2011120579720Open ↗
10/15/2010120496061Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
03/20/2012120964821Open ↗
02/21/2012120964821Open ↗
10/15/2010120496061Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET4
03/20/2012120964821Open ↗
02/21/2012120964821Open ↗
01/26/2011120579720Open ↗
Showing 3 of 4 on file for this type
▸Other Documents5
▸DOB NOWProperty Ownership Certification4
08/23/2026M00891488-I1Open ↗
08/23/2026M00891488-P9Open ↗
08/23/2026M00891488-P1Open ↗
Showing 3 of 4 on file for this type
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
09/26/2012120964821Open ↗