← Back
Two stories - detached, small or mid-size
107 PATTEN STREET
STATEN ISLAND · BIN 5088970
💬 Discuss this project
1899Year Built
3Stories
A1Building Class
R1-2Zoning
3,274 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 16,680 sf lot · 0.2 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingGeneral
Permit Issued — active, not yet Signed-off
Floor 2Under Construction13p · 1 filing · 20 docs
Floor 1Under Construction26p · 2 filings · 20 docs
CellarUnder Construction27p · 2 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ROGERS CALVANICO GROUP PLLC1003/20/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
STANTON CONSTRUCTION CORPGeneral Contractor807/08/2026
ADVANCED PLUMBING MECHPlumbing407/08/2026
BERGER QUALITY ELEC'L CONElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738303/20/2026
C&P DESIGN CONSULTANT8472403/20/2026
SRA PLANNING & EXPEDITING5677403/20/2026
Building Lifecycle
All (69)Filed (10)Permit Issued (11)Violation (1)Inspection (13)Objection (4)Special Inspection (30)
08/07/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/04/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/27/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/02/2026
Special inspection requirement — Interior lighting power
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Permanent certificate
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Metering
Stanislav Pilipenko
04/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Final
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Concrete - Cast-In-Place
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
anthony santoro
04/02/2026
Special inspection requirement — Subgrade Inspections
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Structural Steel - Details
WILLIAM MONTAGUE
04/02/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
WILLIAM MONTAGUE
04/02/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Footing and Foundation
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Fire-Resistance Rated Construction
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Energy Code Compliance Inspections
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Structural Wood Frame
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Insulation placement and R values
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Fenestration air leakage
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Stanislav Pilipenko
04/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Stanislav Pilipenko
04/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Duct leakage testing, insulation and design
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Protection of exposed foundation insulation
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Fenestration areas
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Air barrier - visual inspection
Stanislav Pilipenko
04/02/2026
Special inspection requirement — Electric vehicle service equipment requirements
Stanislav Pilipenko
03/25/2026
Permit issued — Plumbing
S00958668-I1-PL
03/24/2026
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
anthony santoro
03/20/2026
Filed — Alteration
OIL TO GAS CONVERSION, INSTALL NEW BOILER AND INDIRECT HW TANK WITH RECONNECTION TO EXISTING DISTRIBUTION IN CELLAR.
S00958668-P1
03/20/2026
Filed — Alteration
PLUMBING APPLICATION FILED IN CONJUNCTION WITH ALTERATION FILING FOR RENOVATION TO BUILDING
S01093499-P5
03/20/2026
Filed — Alteration
PLUMBING APPLICATION FILED IN CONJUNCTION WITH ALTERATION FILING FOR RENOVATION TO BUILDING
S01093499-P4
03/13/2026
Special inspection requirement — HVAC-R and service water heating equipment
Stanislav Pilipenko
03/13/2026
Special inspection requirement — HVAC-R and service water heating system controls
Stanislav Pilipenko
03/13/2026
Special inspection requirement — Maintenance information
Stanislav Pilipenko
01/30/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/23/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/21/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/15/2026
Permit issued — Plumbing
S01093499-S1-PL
01/12/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
11/19/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/10/2025
Filed — Alteration
PLUMBING APPLICATION FILED IN CONJUNCTION WITH ALTERATION FILING FOR RENOVATION TO BUILDING
S01093499-P3
10/10/2025
Filed — Alteration
PLUMBING APPLICATION FILED IN CONJUNCTION WITH ALTERATION FILING FOR RENOVATION TO BUILDING
S01093499-P2
08/07/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/07/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/30/2025
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
05/21/2025
Objection resolved — Addressed
05/20/2025
Objection raised — Scope
05/14/2025
Filed — Alteration
PLUMBING APPLICATION FILED IN CONJUNCTION WITH ALTERATION FILING FOR RENOVATION TO BUILDING
S01093499-P1
05/13/2025
Permit issued — Construction Fence
S01058339-I1-FN
05/13/2025
Permit issued — General Construction
S01093499-I1-FO
05/13/2025
Permit issued — Foundation
S01093499-I1-FO
05/08/2025
Permit issued — General Construction
S01093499-I1-GC-CX
05/07/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/01/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/10/2024
Permit issued — General Construction
S01093499-I1-GC-CX
12/09/2024
Permit issued — Foundation
S01093499-I1-FO
12/05/2024
Permit issued — Plumbing
S00958668-I1-PL
Latest 60 of 69 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedADVANCED PLUMBING MECH03/25/2026
DOB NOWPlumbingPermit IssuedADVANCED PLUMBING MECH01/15/2026
DOB NOWConstruction FencePermit IssuedSTANTON CONSTRUCTION CORP05/13/2025
DOB NOWGeneral ConstructionPermit IssuedSTANTON CONSTRUCTION CORP05/13/2025
DOB NOWFoundationPermit IssuedSTANTON CONSTRUCTION CORP05/13/2025
DOB NOWGeneral ConstructionPermit IssuedSTANTON CONSTRUCTION CORP05/08/2025
DOB NOWGeneral ConstructionPermit IssuedSTANTON CONSTRUCTION CORP12/10/2024
DOB NOWFoundationPermit IssuedSTANTON CONSTRUCTION CORP12/09/2024
DOB NOWPlumbingPermit IssuedADVANCED PLUMBING MECH12/05/2024
DOB NOWPlumbingPermit IssuedADVANCED PLUMBING MECH12/05/2024
DOB NOWConstruction FencePermit IssuedSTANTON CONSTRUCTION CORP05/31/2024
BISOTISSUEDCENTURION SOLAR ENERGY08/24/2020
2 projects · most recent 03/20/2026
Gas Water/Sanitary Storm
FiledStatusContractorScope
03/20/2026Permit IssuedADVANCED PLUMBING MECHGas, Water/Sanitary
03/20/2026Permit IssuedADVANCED PLUMBING MECHGas, Storm, Water/Sanitary
4 projects · most recent 05/11/2026
General Wiring
FiledStatusContractorScope
05/11/2026Permit IssuedCATELLO ELEC'L CONT., INC1 meters, 1 new_meters
09/25/2025Permit IssuedDIDONATO & SONS ELCL CONTGeneral Wiring
12/21/2023Permit IssuedDIDONATO & SONS ELCL CONT—
09/02/2020CompleteBERGER QUALITY ELEC'L CON—
1 project · most recent 03/20/2026
Steel Wood
FiledStatusContractorScope
03/20/2026Permit IssuedADVANCED PLUMBING MECHSteel, Wood
1 project · most recent 05/29/2024
Fence
FiledStatusContractorScope
05/29/2024Permit IssuedSTANTON CONSTRUCTION CORPFence
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
08/07/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/04/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/27/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
01/30/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/23/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/21/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/12/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/19/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/07/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/07/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/30/2025Pass-Final PL - UndergroundPassView ↗
05/07/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/01/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 85
DateRequirementInspectorRole
04/02/2026Electric vehicle service equipment requirementsStanislav Pilipenkoenergy_progress
04/02/2026Permanent certificateStanislav Pilipenkoenergy_progress
04/02/2026HVAC-R and service water heating equipmentStanislav Pilipenkoenergy_progress
04/02/2026MeteringStanislav Pilipenkoenergy_progress
04/02/2026Interior lighting powerStanislav Pilipenkoenergy_progress
04/02/2026FinalStanislav Pilipenkoprogress
04/02/2026Concrete - Cast-In-PlaceStanislav Pilipenkospecial
04/02/2026Subsurface Investigations (Borings/Test Pits)anthony santorospecial
04/02/2026Subgrade InspectionsStanislav Pilipenkospecial
04/02/2026Structural Steel - DetailsWILLIAM MONTAGUEspecial
04/02/2026Structural Stability – Alterations of existing buildingsWILLIAM MONTAGUEspecial
04/02/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationStanislav Pilipenkospecial
04/02/2026Fire-Resistant Penetrations and JointsStanislav Pilipenkospecial
04/02/2026Footing and FoundationStanislav Pilipenkoprogress
04/02/2026Fire-Resistance Rated ConstructionStanislav Pilipenkoprogress
04/02/2026Energy Code Compliance InspectionsStanislav Pilipenkoprogress
04/02/2026Structural Wood FrameStanislav Pilipenkoprogress
04/02/2026Insulation placement and R valuesStanislav Pilipenkoenergy_progress
04/02/2026Fenestration air leakageStanislav Pilipenkoenergy_progress
04/02/2026Fenestration and door U-factor and product ratingsStanislav Pilipenkoenergy_progress
04/02/2026HVAC-R and service water piping design and insulationStanislav Pilipenkoenergy_progress
04/02/2026HVAC-R and service water heating system controlsStanislav Pilipenkoenergy_progress
04/02/2026Duct leakage testing, insulation and designStanislav Pilipenkoenergy_progress
04/02/2026Protection of exposed foundation insulationStanislav Pilipenkoenergy_progress
04/02/2026Fenestration areasStanislav Pilipenkoenergy_progress
Latest 25 of 85.
▾Documents — 125 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/21/2026S01058339-I1Request digital key ↗
08/20/2026S01093499-S1Request digital key ↗
08/20/2026S01093499-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION1
08/21/2020540181792Open ↗
▸BISWORK PERMIT APPLICATION1
08/24/2020540181792Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
10/01/2024540264685Open ↗
▸Zoning, Tax Lot & Property Records14
▸DOB NOWRestrictive Declaration/Easement 16
08/20/2026S01093499-S1Open ↗
08/20/2026S01093499-I1Open ↗
08/20/2026S01093499-P3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram4
08/20/2026S01093499-I1Open ↗
08/20/2026S01093499-P2Open ↗
08/20/2026S01093499-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZoning Exhibit form (1-5)4
08/20/2026S01093499-P1Open ↗
08/20/2026S01093499-I1Open ↗
08/20/2026S01093499-P2Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications43
▸DOB NOWSpecial Inspector Seal & Signature17
09/01/2026S01093499-P2Open ↗
09/01/2026S01093499-P2Open ↗
09/01/2026S01093499-P2Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
09/01/2026S01093499-P2Open ↗
09/01/2026S01093499-P2Open ↗
09/01/2026S01093499-P2Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/20/2026S01093499-S1Open ↗
08/20/2026S01093499-I1Open ↗
08/20/2026S01093499-P3Open ↗
Showing 3 of 10 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
08/22/2024540264685Open ↗
08/21/2020540181792Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
08/21/2020540181792Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/21/2020540181792Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
08/22/2024540264685Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)4
08/20/2026S01093499-I1Open ↗
08/20/2026S01093499-P2Open ↗
08/20/2026S01093499-P1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
08/21/2020540181792Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/20/2026S01093499-S1Open ↗
08/20/2026S01093499-I1Open ↗
08/20/2026S01093499-P3Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/21/2020540181792Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
12/10/2021540181792Open ↗
08/21/2020540181792Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
08/21/2020540181792Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
08/21/2020540181792Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
12/10/2021540181792Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
12/10/2021540181792Open ↗
▸Inspections & Test Reports9
▸DOB NOWSOIL REPORT4
08/20/2026S01093499-P2Open ↗
08/20/2026S01093499-P1Open ↗
08/20/2026S01093499-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY3
08/22/2024540264685Open ↗
12/10/2021540181792Open ↗
08/21/2020540181792Open ↗
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
08/22/2024540264685Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S01093499-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
10/01/2024540264685Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/13/2021540181792Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
08/21/2020540181792Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
12/10/2021540181792Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
08/21/2020540181792Open ↗
▸BISADDITIONAL INFORMATION1
10/01/2024540264685Open ↗
▸Other Documents19
▸DOB NOWSite Survey: Initial4
08/20/2026S01093499-I1Open ↗
08/20/2026S01093499-P2Open ↗
08/20/2026S01093499-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/20/2026S01093499-P1Open ↗
08/20/2026S01093499-I1Open ↗
08/20/2026S01093499-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlot Diagram4
08/20/2026S01093499-I1Open ↗
08/20/2026S01093499-P2Open ↗
08/20/2026S01093499-P1Open ↗
Showing 3 of 4 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION3
10/01/2024540264685Open ↗
09/26/2024540264685Open ↗
08/22/2024540264685Open ↗
▸BISBPP: TOPOGRAPHIC SURVEY1
08/29/2024540264685Open ↗
▸BISDOT WAIVER OF CURB ALIGNMENT1
09/26/2024540264685Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
08/29/2024540264685Open ↗
▸BISTax Abatement Miscellaneous1
12/13/2021540181792Open ↗