← Back
One family attached or semi-detached
1073 EAST 3 STREET
BROOKLYN · Mapleton-Midwood (West) · BIN 3170748
💬 Discuss this project
1930Year Built
2Stories
A5Building Class
R3-1Zoning
1,248 sfGross Floor Area
1Units
One family attached or semi-detached · Owner of record: 1073 EAST 3RD ST LLC · 2,000 sf lot · 0.62 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanical
Floor 230p · 1 filing · 20 docs
Floor 130p · 1 filing · 20 docs
Cellar31p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/29/2021$1.1M—Private party → Private party$865/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GARFINKEL ARCHITECT, PLLC203/09/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&T CONSULTANTS LLCGeneral Contractor603/21/2026
PLATINUM BUILDERS INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AZ PROFESSIONAL ENGINEERI766203/09/2023
Building Lifecycle
All (50)Filed (2)Permit Issued (3)Objection (20)Special Inspection (25)
06/30/2025
Permit issued — Mechanical Systems
B00762355-I1-GC
05/12/2023
Permit issued — General Construction
B00762355-I1-GC
04/20/2023
Permit issued — Structural
B00762355-I1-GC
03/09/2023
Filed — Alteration CO
Extend the existing 2 story building at all floors. Add new Attic
B00762355-P1
03/09/2023
Special inspection requirement — Concrete - Cast-In-Place
VIJAY KUMAR
03/09/2023
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
VIJAY KUMAR
03/09/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
VIJAY KUMAR
03/09/2023
Special inspection requirement — Masonry
VIJAY KUMAR
03/09/2023
Special inspection requirement — Mechanical Systems
VIJAY KUMAR
03/09/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
VIJAY KUMAR
03/09/2023
Special inspection requirement — Subgrade Inspections
VIJAY KUMAR
03/09/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Daniel Boss
03/09/2023
Special inspection requirement — Energy Code Compliance Inspections
VIJAY KUMAR
03/09/2023
Special inspection requirement — Final
VIJAY KUMAR
03/09/2023
Special inspection requirement — Fire-Resistance Rated Construction
VIJAY KUMAR
03/09/2023
Special inspection requirement — Footing and Foundation
VIJAY KUMAR
03/09/2023
Special inspection requirement — Structural Wood Frame
VIJAY KUMAR
03/09/2023
Special inspection requirement — Interior lighting power
VIJAY KUMAR
03/09/2023
Special inspection requirement — HVAC-R and service water heating system controls
VIJAY KUMAR
03/09/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
VIJAY KUMAR
03/09/2023
Special inspection requirement — Permanent certificate
03/09/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
VIJAY KUMAR
03/09/2023
Special inspection requirement — Air barrier - visual inspection
VIJAY KUMAR
03/09/2023
Special inspection requirement — Protection of exposed foundation insulation
03/09/2023
Special inspection requirement — Insulation placement and R values
VIJAY KUMAR
03/09/2023
Special inspection requirement — Fenestration areas
VIJAY KUMAR
03/09/2023
Special inspection requirement — Electric vehicle service equipment requirements
VIJAY KUMAR
03/09/2023
Special inspection requirement — Fenestration air leakage
VIJAY KUMAR
03/09/2023
Special inspection requirement — HVAC-R and service water heating equipment
VIJAY KUMAR
02/23/2023
Objection raised — Other
02/23/2023
Objection resolved — Addressed
02/23/2023
Objection raised — Other
02/23/2023
Objection resolved — Addressed
02/23/2023
Objection raised — Other
02/23/2023
Objection resolved — Addressed
02/09/2023
Objection raised — Other
02/09/2023
Objection resolved — Addressed
02/09/2023
Objection raised — Other
02/09/2023
Objection resolved — Addressed
02/09/2023
Objection raised — Other
02/09/2023
Objection resolved — Addressed
09/19/2022
Objection raised — Other
09/19/2022
Objection resolved — Addressed
09/14/2022
Objection raised — Other
09/14/2022
Objection resolved — Addressed
09/14/2022
Objection raised — Other
09/14/2022
Objection resolved — Addressed
09/02/2022
Objection raised — Other
09/02/2022
Objection resolved — Addressed
08/09/2022
Filed — Alteration CO
Extend the existing 2 story building at all floors. Add new Attic
B00762355-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedPLATINUM BUILDERS INC06/30/2025
DOB NOWGeneral ConstructionPermit IssuedL&T CONSULTANTS LLC05/12/2023
DOB NOWStructuralPermit IssuedL&T CONSULTANTS LLC04/20/2023
1 project · most recent 03/09/2023
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/09/2023Permit IssuedPLATINUM BUILDERS INCAir Conditioning Systems, Ventilation Systems
Cooling
Carrier 4 UNITS MODEL # FB4CN4048, I UNIT MODEL# FB4CN4036 15 tons · Ahu ×8
Ventilation
Panasonic Model # 695 80 CFM · Exhaust Fan ×4
Model # FV-0510VS1 80 CFM · Exhaust Fan ×4
General Electric Model # JVX5305SJSS 100 CFM · Kitchen Exhaust ×2
1 project · most recent 03/09/2023
Concrete Masonry Wood
FiledStatusContractorScope
03/09/2023Permit IssuedPLATINUM BUILDERS INCConcrete, Masonry, Wood
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
03/09/2023Concrete - Cast-In-PlaceVIJAY KUMARspecial
03/09/2023Excavations - Sheeting, Shoring, and BracingVIJAY KUMARspecial
03/09/2023Fire-Resistant Penetrations and JointsVIJAY KUMARspecial
03/09/2023MasonryVIJAY KUMARspecial
03/09/2023Mechanical SystemsVIJAY KUMARspecial
03/09/2023Structural Stability – Alterations of existing buildingsVIJAY KUMARspecial
03/09/2023Subgrade InspectionsVIJAY KUMARspecial
03/09/2023Subsurface Investigations (Borings/Test Pits)Daniel Bossspecial
03/09/2023Energy Code Compliance InspectionsVIJAY KUMARprogress
03/09/2023FinalVIJAY KUMARprogress
03/09/2023Fire-Resistance Rated ConstructionVIJAY KUMARprogress
03/09/2023Footing and FoundationVIJAY KUMARprogress
03/09/2023Structural Wood FrameVIJAY KUMARprogress
03/09/2023Interior lighting powerVIJAY KUMARenergy_progress
03/09/2023HVAC-R and service water heating system controlsVIJAY KUMARenergy_progress
03/09/2023Fenestration and door U-factor and product ratingsVIJAY KUMARenergy_progress
03/09/2023Permanent certificate—energy_progress
03/09/2023HVAC-R and service water piping design and insulationVIJAY KUMARenergy_progress
03/09/2023Air barrier - visual inspectionVIJAY KUMARenergy_progress
03/09/2023Protection of exposed foundation insulation—energy_progress
03/09/2023Insulation placement and R valuesVIJAY KUMARenergy_progress
03/09/2023Fenestration areasVIJAY KUMARenergy_progress
03/09/2023Electric vehicle service equipment requirementsVIJAY KUMARenergy_progress
03/09/2023Fenestration air leakageVIJAY KUMARenergy_progress
03/09/2023HVAC-R and service water heating equipmentVIJAY KUMARenergy_progress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026B00762355-P1Request digital key ↗
08/15/2026B00762355-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026B00762355-P1Open ↗
08/13/2026B00762355-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026B00762355-I1Open ↗
08/13/2026B00762355-P1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00762355-P1Open ↗
08/13/2026B00762355-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026B00762355-P1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/13/2026B00762355-I1Open ↗
08/13/2026B00762355-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B00762355-I1Open ↗
08/13/2026B00762355-P1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/13/2026B00762355-P1Open ↗
08/13/2026B00762355-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026B00762355-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00762355-I1Open ↗
▸Other Documents9
▸DOB NOWSite Survey: Initial2
08/13/2026B00762355-I1Open ↗
08/13/2026B00762355-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B00762355-P1Open ↗
08/13/2026B00762355-I1Open ↗
▸DOB NOWPlot Diagram2
08/13/2026B00762355-I1Open ↗
08/13/2026B00762355-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/13/2026B00762355-I1Open ↗
08/13/2026B00762355-P1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00762355-I1Open ↗