| Owner | Filings | Most Recent |
|---|---|---|
| 1073 TIFFANY LLC | 1 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 04/16/2021 | $490K | — | 1073 TIFFANY BX LLC → 1073 TIFFANY LLC | $69/sf building |
| 01/05/2016 | $280K | — | — → — | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| NODE ARCHITECTURE,ENGINEERING, CONS | 10 | 04/14/2022 |
| SYED ENGINEERING, P.C. | 1 | 02/16/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| NODE ENGINEERING CONSULTING | 10 | 03/21/2026 |
| CONSOLIDATED SCAFFOLD BRIDGE | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| WALL TO WALL CONSTRUCTIO* | General Contractor | 14 | 07/08/2026 |
| BOND CONSTRUCTION INC | General Contractor | 5 | 07/08/2026 |
| CONSOLIDATED SCAFFOLDING | General Contractor | 3 | 03/21/2026 |
| V. VASS ELECTRIC CORP | Electrical | 1 | 03/22/2026 |
| LLOYD G DRUMMOND PLBG&GEN | Fire Protection | 1 | 07/08/2026 |
| LLOYD G DRUMMOND PLBG&GEN | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| INTERNATIONAL GEOTEHCNICA | 1795 | 5 | 04/14/2022 |
| NODE ARCHITECTURE,ENGINEE | 6799 | 7 | 04/14/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | WALL TO WALL CONSTRUCTIO* | 04/25/2024 |
| DOB NOW | General Construction | Permit Issued | WALL TO WALL CONSTRUCTIO* | 04/27/2023 |
| DOB NOW | General Construction | Permit Issued | WALL TO WALL CONSTRUCTIO* | 02/21/2023 |
| DOB NOW | Mechanical Systems | Signed-off | WALL TO WALL CONSTRUCTIO* | 02/15/2023 |
| DOB NOW | Protection and Mechanical Methods | Signed-off | WALL TO WALL CONSTRUCTIO* | 02/15/2023 |
| DOB NOW | Construction Fence | Signed-off | WALL TO WALL CONSTRUCTIO* | 08/18/2022 |
| DOB NOW | General Construction | Permit Issued | WALL TO WALL CONSTRUCTIO* | 08/17/2022 |
| DOB NOW | General Construction | Permit Issued | WALL TO WALL CONSTRUCTIO* | 07/13/2022 |
| DOB NOW | Sprinklers | Signed-off | LLOYD G. DRUMMOND | 03/31/2022 |
| DOB NOW | Plumbing | Signed-off | LLOYD G DRUMMOND PLBG&GEN | 03/30/2022 |
| DOB NOW | Sidewalk Shed | Signed-off | CONSOLIDATED SCAFFOLDING | 02/17/2022 |
| DOB NOW | Structural | Signed-off | BOND CONSTRUCTION INC | 02/01/2022 |
| DOB NOW | Foundation | Signed-off | BOND CONSTRUCTION INC | 11/19/2021 |
| DOB NOW | Construction Fence | Signed-off | BOND CONSTRUCTION INC | 08/23/2021 |
| BIS | — | ISSUED | GATEWAY DEMOLITION CORP. | 09/15/1994 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 03/10/2022 | Permit Issued | WALL TO WALL CONSTRUCTIO* | Heating and Air Conditioning Systems | Heat / Cool Mitsubishi Electric MSZ-GL09NA/ NTTXWST12A112AA 399 CFM · Split System ×16 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/11/2023 | Complete | DENNISON ELECTRIC CORP | General Wiring |
| 02/17/2022 | Complete | V. VASS ELECTRIC CORP | — |
| Date | Type | Result | Report |
|---|---|---|---|
| 01/30/2026 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 05/22/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 02/14/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 02/14/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 08/13/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 09/11/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 05/26/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 05/05/2023 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 05/27/2022 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 05/06/2022 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 05/06/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 04/01/2022 | Protection of exposed foundation insulation | Radomir Delic | energy_progress |
| 04/01/2022 | Metering | Radomir Delic | energy_progress |
| 04/01/2022 | Maintenance information | Radomir Delic | energy_progress |
| 03/03/2022 | Duct leakage testing, insulation and design | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 03/03/2022 | HVAC-R and service water heating system controls | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 03/03/2022 | Shutoff dampers | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 03/03/2022 | Final | Radomir Delic | progress |
| 03/03/2022 | Fire-Resistant Penetrations and Joints | Radomir Delic | special |
| 03/03/2022 | Mechanical Systems | MICHAEL KARANTINIDIS, P.E. | special |
| 03/03/2022 | Energy Code Compliance Inspections | MICHAEL KARANTINIDIS, P.E. | progress |
| 03/03/2022 | Heating Systems | MICHAEL KARANTINIDIS, P.E. | special |
| 03/03/2022 | HVAC-R and service water heating equipment | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 03/03/2022 | Maintenance information | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 03/03/2022 | HVAC-R and service water piping design and insulation | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 01/25/2022 | Masonry | Radomir Delic | special |
| 01/25/2022 | Structural Cold-Formed Steel | Radomir Delic | special |
| 10/13/2021 | Concrete - Cast-In-Place | Radomir Delic | special |
| 10/13/2021 | Excavations - Sheeting, Shoring, and Bracing | Radomir Delic | special |
| 10/13/2021 | Subgrade Inspections | Radomir Delic | special |
| 10/13/2021 | Subsurface Conditions – Fill Placement & In-Place Density | MICHAEL KARANTINIDIS, P.E. | special |
| 07/20/2021 | Insulation placement and R values | Radomir Delic | energy_progress |
| 07/20/2021 | Lighting in dwelling units | Radomir Delic | energy_progress |
| 07/20/2021 | Fenestration air leakage | Radomir Delic | energy_progress |
| 07/20/2021 | Fenestration areas | Radomir Delic | energy_progress |
| 07/20/2021 | Lighting controls | Radomir Delic | energy_progress |