← Back
Two stories - detached, small or mid-size
1078 WARING AVENUE
BRONX · BIN 2050208
💬 Discuss this project
1935Year Built
2.5Stories
A1Building Class
R4AZoning
2,028 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,200 sf lot · 0.63 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 11p · 1 filing · 12 docs
Basement3p · 1 filing · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AR CONSTRUCTION MGMT603/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/19/2023$825K—Private party → Private party$407/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW AGE ENGINEERING PLLC212/08/2025
NORMAN C. LOK, PE111/26/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
W J PROFESSIONAL EXPEDITING COMPANY603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KURT EBINGER ELEC CONSTElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW AGE ENGINEERING PLLC7746212/08/2025
Building Lifecycle
All (14)Filed (3)Objection (9)Special Inspection (2)
02/08/2026
Objection resolved — Addressed
02/06/2026
Objection resolved — Resolved
02/06/2026
Objection resolved — Resolved
01/09/2026
Objection resolved — Addressed
12/12/2025
Objection raised — Plumbing
12/12/2025
Objection raised — Admin
12/12/2025
Objection raised — Mechanical
12/08/2025
Filed — Alteration CO
FILING FOR MECHANICAL WORK FOR DAYCARE SPACE IN BASEMENT AS PER PLANS FILED HEREWITH.
X01260795-S4
12/08/2025
Filed — Alteration CO
FILING FOR MECHANICAL WORK FOR DAYCARE SPACE IN BASEMENT AS PER PLANS FILED HEREWITH.
X01260795-S3
12/04/2025
Objection raised — Zoning
12/04/2025
Objection raised — Zoning
12/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
12/04/2025
Special inspection requirement — Tenant Protection Plan Compliance
Stephen Shishko
11/26/2025
Filed — Alteration CO
FILING FOR MECHANICAL WORK FOR DAYCARE SPACE IN BASEMENT AS PER PLANS FILED HEREWITH.
X01260795-I1
Nothing on file for this building.
1 job · most recent 12/08/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
12/08/2025——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MSZ-GS09NA 10,900 BTU · Fan Coil Indoor ×2
MXZ-2C20NA1 21,600 BTU · Vrf Outdoor ×1
Ventilation
Mitsubishi Electric LGHF-300RVX-E 225 CFM · Erv ×1
1 job · most recent 01/25/2022
FiledStatusContractorScope
01/25/2022Permit IssuedKURT EBINGER ELEC CONST1 meters
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
12/04/2025Fire-Resistant Penetrations and JointsStephen Shishkospecial
12/04/2025Tenant Protection Plan ComplianceStephen Shishkospecial
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026X01260795-S4Request digital key ↗
08/17/2026X01260795-S3Request digital key ↗
08/17/2026X01260795-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026X01260795-S4Open ↗
08/17/2026X01260795-S3Open ↗
08/17/2026X01260795-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026X01260795-S4Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/17/2026X01260795-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/17/2026X01260795-S4Open ↗
08/17/2026X01260795-I1Open ↗
08/17/2026X01260795-S3Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/17/2026X01260795-I1Open ↗