← Back
Elevator cooperative
Oakwood North & South
108-49 63 AVENUE · Forest Hills · BIN 4051521
💬 Discuss this project
1963Year Built
6Stories
D4Building Class
R6Zoning
99,613 sfGross Floor Area
100Units
LL97 CoveredRent Stabilized155 Open Violations 147 unresolved · 8 paperwork only ▸FISP: SWARMP
Elevator cooperative · Owner of record: OAKWOOD NORTH & SOUTH OWNERS CORP · 30,825 sf lot · 3.23 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Permit Issued — active, not yet Signed-off
RoofUnder Construction8p · 1 filing · 7 docs
Floor 1Under Construction3p · 1 filing · 15 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW YORK LADDER & SCAFFOLD507/08/2026
TITAN SERVICES USA106/02/2026
OAKWOOD NORTH SOUTH OWNERS2703/22/2026
FRE MANAGEMENT603/22/2026
DELKAP MANAGEMENT703/21/2026
METRO CONTRACTING NY503/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A D BUILDING SOLUTIONS803/21/2026
DESIGN COMMUNICATION MK103/21/2026
A1 EXPEDITING SERVICE203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A & GV STUCCO CONSTR CORPGeneral Contractor203/21/2026
CUBE BUILDERS GROUP NYGeneral Contractor204/09/2026
NEW YORK LADDER & SCAFFOLDGeneral Contractor207/08/2026
SANDHA GENERAL CONTRACTINElectrical103/21/2026
SEGA ELECTRIC LLCElectrical103/22/2026
ALMA DEVELOPERS LLCGeneral Contractor106/27/2026
TEAMWORK ENTERPRISES INCGeneral Contractor107/08/2026
TITAN SERVICES USA INCGeneral Contractor106/02/2026
CHETRAM, RISHIRAMElectrical103/21/2026
AMC PLBG, HTG & CLNG, INCPlumbing107/08/2026
MOTTES, STEVEElectrical103/21/2026
QUINTANA, DAVIDElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CARUSONE & CHERRES ARCHIT6166105/06/2026
AMINOV DESIGN ENGINEER, P9365505/04/2026
BITOPI CONSULTANTS LLC7036103/30/2026
KOENIGSBERG ENGINEERING,2247103/30/2026
CEYLAN DESIGN AND CONSULT8422102/13/2024
NORMAN C. LOK818108/10/2021
Building Lifecycle
All (155)Filed (12)Permit Issued (9)Signed Off (4)Facade (FISP) (16)Violation (60)Inspection (10)Objection (26)Special Inspection (18)
07/23/2026
Violation issued (HPD, open)
B
07/23/2026
Violation issued (HPD, open)
A
07/23/2026
Violation issued (HPD, open)
B
07/23/2026
Violation issued (HPD, open)
B
07/23/2026
Violation issued (HPD, open)
A
07/15/2026
Violation issued (ECB, open)
Unknown
07/10/2026
Violation issued (ECB, open)
Construction
07/10/2026
Violation issued (ECB, open)
Unknown
07/10/2026
Violation issued (ECB, open)
Construction
07/10/2026
Violation issued (ECB, open)
Construction
07/08/2026
Violation issued (HPD, open)
C
07/08/2026
Violation issued (HPD, open)
C
07/06/2026
Signed off — Alteration
APPLICATION FILED FOR PLUMBING WORK ONLY AT APARTMENT 1A & 1B. EXISTING FIXTURES ARE BEING CAPPED AND REMOVED AND RELOCATED, WORK ALSO INCLUDES INSTALLATION OF NEW PLUMBING AND GAS FIXTURES AND PIPING AS SHOW IN PLANS
Q01268782-I1
07/06/2026
Signed off — Alteration
MECHANICAL WORK FILED TO FURNISH AND INSTALL NEW HVAC EQUIPMENT IN CONJUNCTION TO ALT APPLICATION NUMBER Q01236981-I1
Q01236981-I1
07/06/2026
Signed off — Alteration
MECHANICAL WORK FILED TO FURNISH AND INSTALL NEW HVAC EQUIPMENT IN CONJUNCTION TO ALT APPLICATION NUMBER Q01236981-I1
Q01236981-S1
07/06/2026
Violation issued (ECB, open)
Construction
07/06/2026
Violation issued (ECB, open)
Unknown
07/02/2026
Violation issued (HPD, open)
C
07/02/2026
Violation issued (HPD, open)
A
07/02/2026
Violation issued (HPD, open)
C
06/26/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/16/2026
Permit issued — General Construction
Q01397688-I1-GC
05/20/2026
Violation issued (HPD, open)
C
05/20/2026
Violation issued (HPD, open)
C
05/20/2026
Violation issued (HPD, closed)
C
05/20/2026
Violation issued (HPD, open)
A
05/06/2026
Filed — Alteration
Q01397688-I1
05/06/2026
Violation issued (HPD, open)
A
05/05/2026
Permit issued — General Construction
Q01372728-I1-GC
05/05/2026
Special inspection requirement — Final
GIANMARCO CARUSONE
05/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
JORGE CHERRES
05/05/2026
Special inspection requirement — Fire-Resistance Rated Construction
GIANMARCO CARUSONE
05/04/2026
Filed — Alteration
MECHANICAL WORK FILED TO FURNISH AND INSTALL NEW HVAC EQUIPMENT IN CONJUNCTION TO ALT APPLICATION NUMBER Q01236981-I1
Q01236981-P1
04/02/2026
Permit issued — Sidewalk Shed
Q01375379-I1-SH
03/31/2026
Filed — Alteration
INSTALLATION OF 300PSF SIDEWALK SHED AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CH #33 OF THE NYC CODE 2022. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
Q01375379-I1
03/30/2026
Filed — Alteration
EXTERIOR RESTORATION AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
Q01372728-I1
03/16/2026
Special inspection requirement — Masonry
RICHARD KOENIGSBERG
03/16/2026
Special inspection requirement — Tenant Protection Plan Compliance
KAMRUL AHSAN
03/16/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
RICHARD KOENIGSBERG
03/16/2026
Special inspection requirement — Final
RICHARD KOENIGSBERG
02/25/2026
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
01/28/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
01/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MARK AMINOV
01/15/2026
Violation issued (HPD, open)
C
01/15/2026
Violation issued (HPD, open)
B
01/15/2026
Violation issued (HPD, open)
B
01/15/2026
Violation issued (HPD, open)
B
01/15/2026
Violation issued (HPD, open)
B
01/15/2026
Violation issued (HPD, open)
B
01/15/2026
Violation issued (HPD, closed)
C
01/15/2026
Violation issued (HPD, closed)
C
01/15/2026
Violation issued (HPD, open)
A
01/15/2026
Violation issued (HPD, open)
B
01/15/2026
Violation issued (HPD, closed)
C
01/15/2026
Violation issued (HPD, closed)
A
01/15/2026
Violation issued (HPD, open)
C
01/07/2026
Filed — Alteration
APPLICATION FILED FOR PLUMBING WORK ONLY AT APARTMENT 1A & 1B. EXISTING FIXTURES ARE BEING CAPPED AND REMOVED AND RELOCATED, WORK ALSO INCLUDES INSTALLATION OF NEW PLUMBING AND GAS FIXTURES AND PIPING AS SHOW IN PLANS
Q01268782-P2
12/09/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
12/01/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/28/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
Latest 60 of 155 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offALMA DEVELOPERS LLC06/16/2026
DOB NOWGeneral ConstructionPermit IssuedTEAMWORK ENTERPRISES INC05/05/2026
DOB NOWSidewalk ShedPermit IssuedTITAN SERVICES USA INC04/02/2026
DOB NOWMechanical SystemsPermit IssuedCUBE BUILDERS GROUP NY10/08/2025
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC10/08/2025
DOB NOWGeneral ConstructionSigned-offCUBE BUILDERS GROUP NY10/02/2025
DOB NOWGeneral ConstructionSigned-offA GV STUCCO CONSTR03/13/2024
DOB NOWSidewalk ShedPermit IssuedNEW YORK LADDER & SCAFFOL03/11/2020
DOB NOWSidewalk ShedPermit IssuedNEW YORK LADDER & SCAFFOL11/22/2019
BISOTISSUEDKNS BUILDING REST. INC03/24/2021
BISOTISSUEDKNS BUILDING REST. INC03/23/2020
BISOTISSUEDKNS BUILDING REST. INC02/10/2020
BISEQISSUEDMETRO CONTRACTING NY, INC.02/28/2018
BISOTISSUEDSONS & S CONSTRUCTION INC07/12/2017
BISOTISSUEDSONS & S CONSTRUCTION INC04/13/2017
BISOTISSUEDSONS CONSTRUCTION INC02/06/2017
BISEQISSUEDMETRO CONTRACTING NY, INC.12/19/2016
BISOTISSUEDSONS CONSTRUCTION INC06/29/2012
BISEQISSUEDSONS CONSTRUCTION INC06/29/2012
BISEQISSUEDMETRO CONTRACTING NY, INC.06/14/2012
BISOTISSUEDSONS CONSTRUCTION INC09/15/2011
BISPLISSUEDAUSTIN PLBG & HTG CO.INC03/02/2010
BISOTISSUEDGIM CONSTRUCTION INC03/02/2010
BISBLISSUEDACE-ATLAS PLBING & HTG08/24/2005
BISPLISSUEDACE-ATLAS PLBING & HTG08/24/2005
BISEQISSUEDSPRING SCAFFOLDING INC.06/30/1999
1 project · most recent 05/04/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/04/2026Permit IssuedCUBE BUILDERS GROUP NYHeating and Air Conditioning Systems
Heat / Cool
Tosot TM36D6MO 36,000 BTU · Split System ×1
TM48D6MO 48,000 BTU · Split System ×1
2 projects · most recent 01/07/2026
Gas Water/Sanitary
FiledStatusContractorScope
01/07/2026Signed-offAMC PLBG, HTG & CLNG, INCGas, Water/Sanitary
02/13/2024——Gas, Water/Sanitary
6 projects · most recent 04/15/2026
General Wiring
FiledStatusContractorScope
04/15/2026Permit IssuedTIMOTHY COLEMAN LICENSEDGeneral Wiring
04/02/2026Permit IssuedRICHARD NEU—
04/01/2026Permit IssuedTIMOTHY COLEMAN LICENSEDGeneral Wiring
04/14/2025CompletePOWERONE ELECT'L CONTRGGeneral Wiring
10/02/2023Permit IssuedSEGA ELECTRIC LLCGeneral Wiring
11/06/2019Permit IssuedV. VASS ELECTRIC CORP—
1 project · most recent 03/31/2026
Sidewalk Shed
FiledStatusContractorScope
03/31/2026Permit IssuedTITAN SERVICES USA INCSidewalk Shed
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
06/26/2026Pass-Final General Construction Non-Directive 14PassView ↗
02/25/2026No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
01/28/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
12/09/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
12/01/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/28/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/28/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/28/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/24/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/24/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
05/05/2026FinalGIANMARCO CARUSONEprogress
05/05/2026Fire-Resistant Penetrations and JointsJORGE CHERRESspecial
05/05/2026Fire-Resistance Rated ConstructionGIANMARCO CARUSONEprogress
03/16/2026MasonryRICHARD KOENIGSBERGspecial
03/16/2026Tenant Protection Plan ComplianceKAMRUL AHSANspecial
03/16/2026Structural Stability – Alterations of existing buildingsRICHARD KOENIGSBERGspecial
03/16/2026FinalRICHARD KOENIGSBERGprogress
01/22/2026Fire-Resistant Penetrations and JointsMARK AMINOVspecial
09/08/2025HVAC-R and service water heating system controlsMARK AMINOVenergy_progress
09/08/2025Maintenance informationMARK AMINOVenergy_progress
09/08/2025HVAC-R and service water piping design and insulationMARK AMINOVenergy_progress
09/08/2025HVAC-R and service water heating equipmentMARK AMINOVenergy_progress
08/22/2025Energy Code Compliance InspectionsMARK AMINOVprogress
08/22/2025Mechanical SystemsMARK AMINOVspecial
08/22/2025FinalMARK AMINOVprogress
02/23/2024Fire-Resistant Penetrations and JointsSERDAR CEYLANspecial
02/23/2024Energy Code Compliance InspectionsSERDAR CEYLANprogress
02/13/2024FinalSERDAR CEYLANprogress
▾Documents — 137 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch11
08/27/2026Q00569806-I1Request digital key ↗
08/23/2026Q00999260-I1Request digital key ↗
08/23/2026Q01004740-I1Request digital key ↗
Showing 3 of 11 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed1
08/28/2026Q00256935-I1Request digital key ↗
▸Applications & Permits19
▸BISWORK PERMIT APPLICATION10
11/06/2019421392148Open ↗
03/05/2018440369245Open ↗
07/18/2017421392148Open ↗
Showing 3 of 10 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION9
08/01/2019421392148Open ↗
08/01/2019421392148Open ↗
07/29/2019421392148Open ↗
Showing 3 of 9 on file for this type
▸Seals & Professional Certifications42
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION12
08/06/2019421392148Open ↗
08/05/2019421392148Open ↗
05/25/2018440369245Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/27/2026Q00569806-I1Open ↗
08/23/2026Q01004740-I1Open ↗
08/20/2026Q01236981-S1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/23/2026Q01236981-S1Open ↗
09/19/2026Q00999260-I1Open ↗
08/31/2026Q01268782-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026Q01236981-S1Open ↗
09/23/2026Q01236981-S1Open ↗
09/23/2026Q01236981-S1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/08/2016440369245Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
06/12/2012420579083Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
12/08/2016440369245Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
12/08/2016440369245Open ↗
▸BISProfessional and Owner Certification (POC3)1
06/12/2012420579083Open ↗
▸Trade Schedules & Equipment3
▸BISSELF-CERT PLUMBING NOTICE2
09/14/2010420143455Open ↗
07/07/2010420143455Open ↗
▸BISSCHEDULE B - PLUMBING1
02/23/2010420143455Open ↗
▸Safety & Tenant Protection7
▸BISSTREET TREE CHECKLIST3
12/05/2016421392148Open ↗
06/08/2012420576914Open ↗
09/02/2011420477433Open ↗
▸BISTenant Protection Plan and Notes3
08/05/2019421392148Open ↗
12/05/2016421392148Open ↗
12/08/2016440369245Open ↗
▸DOB NOWTenant Protection Plan1
08/13/2026Q00256935-I1Open ↗
▸Environmental & Asbestos14
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/27/2026Q00569806-I1Open ↗
08/23/2026Q01004740-I1Open ↗
08/20/2026Q01236981-P1Open ↗
Showing 3 of 10 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
12/05/2016421392148Open ↗
06/08/2012420576914Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
09/02/2011420477433Open ↗
02/23/2010420143455Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
08/05/2019421392148Open ↗
08/05/2019421392148Open ↗
12/05/2016421392148Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
07/13/2021421392148Open ↗
01/09/2013420576914Open ↗
01/09/2013420477433Open ↗
▸BISTECHNICAL REPORT: ENERGY1
09/02/2011420477433Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/13/2021421392148Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
07/13/2021421392148Open ↗
12/08/2016440369245Open ↗
▸Approvals, Objections & Sign-offs13
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
07/13/2021421392148Open ↗
05/25/2018440369245Open ↗
01/09/2013420576914Open ↗
Showing 3 of 5 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
06/12/2012420579083Open ↗
06/08/2012420576914Open ↗
09/02/2011420477433Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
11/06/2019421392148Open ↗
05/25/2018440369245Open ↗
03/05/2018440369245Open ↗
▸BISSUPERSEDING LETTER1
04/21/2017421392148Open ↗
▸Cost, Insurance & Ownership8
▸BISCOST AFFIDAVIT8
07/13/2021421392148Open ↗
08/05/2019421392148Open ↗
12/05/2016421392148Open ↗
Showing 3 of 8 on file for this type
▸Filing & Intake Forms8
▸BISEFILING COVER SHEET5
12/05/2016421392148Open ↗
06/12/2012420579083Open ↗
06/08/2012420576914Open ↗
Showing 3 of 5 on file for this type
▸BISADDITIONAL INFORMATION1
08/05/2019421392148Open ↗
▸BISBOROUGH INTAKE FORM1
05/25/2018440369245Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
12/08/2016440369245Open ↗