← Back
Two family converted from one family
108-50 66 AVENUE
QUEENS · Forest Hills · BIN 4051828
💬 Discuss this project
1940Year Built
2Stories
B3Building Class
R4Zoning
2,280 sfGross Floor Area
2Units
1 Open Violation ▸
Two family converted from one family · 2,000 sf lot · 1.14 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 15 docs
Floor 2Under Construction1p · 1 filing · 15 docs
Floor 1Under Construction1p · 1 filing · 15 docs
CellarUnder Construction3p · 1 filing · 15 docs
Site & exteriorUnder Construction1p · 1 filing · 15 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ISHAC DESIGN ARCHITECTS PC102/06/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LGML GROUP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MID-STATE CONSTRUCTION CGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ISHAC DESIGN ARCHITECTS P3918102/06/2025
Building Lifecycle
All (33)Filed (1)Permit Issued (1)Violation (1)Inspection (6)Objection (16)Special Inspection (8)
04/21/2026
Violation issued (ECB, open)
Construction
04/13/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/25/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/11/2026
Permit issued — General Construction
Q01176677-I1-GC
03/04/2026
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments)
Certified
View inspection ↗
02/19/2026
Objection resolved — Addressed
01/08/2026
Special inspection requirement — Electric vehicle service equipment requirements
NABIL ISHAC
01/08/2026
Special inspection requirement — Fenestration air leakage
NABIL ISHAC
01/08/2026
Special inspection requirement — Energy Code Compliance Inspections
NABIL ISHAC
01/08/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
NABIL ISHAC
01/08/2026
Special inspection requirement — Permanent certificate
NABIL ISHAC
11/24/2025
Objection raised — Energy
11/24/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/10/2025
Special inspection requirement — Insulation placement and R values
NABIL ISHAC
11/10/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NABIL ISHAC
10/30/2025
Objection raised — Inspections
10/30/2025
Objection raised — Zoning
09/02/2025
Objection resolved — Addressed
09/02/2025
Objection resolved — Addressed
08/04/2025
Objection resolved — Addressed
05/26/2025
Inspection — Certified StandPipe - SD - Alarm Sys 64/09 - Finish
Certified
View inspection ↗
05/26/2025
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
05/23/2025
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
03/24/2025
Objection raised — Zoning
03/10/2025
Objection resolved — Addressed
02/20/2025
Objection raised — Admin
02/20/2025
Objection raised — Scope
02/20/2025
Objection raised — Admin
02/20/2025
Objection raised — Structural
02/06/2025
Filed — Alteration CO
Application filed for a conversion of a two-family dwelling into a one family dwelling with 1 accessory Open Parking
Q01176677-I1
02/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NABIL ISHAC
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMID-STATE CONSTRUCTION C03/11/2026
BISPLISSUEDWAGNER ZIV PLUMBING & HEATING CO03/16/2005
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
04/13/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/25/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/04/2026Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments)CertifiedView ↗
05/26/2025Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
05/26/2025Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
05/23/2025Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
01/08/2026Electric vehicle service equipment requirementsNABIL ISHACenergy_progress
01/08/2026Fenestration air leakageNABIL ISHACenergy_progress
01/08/2026Energy Code Compliance InspectionsNABIL ISHACprogress
01/08/2026Fenestration and door U-factor and product ratingsNABIL ISHACenergy_progress
01/08/2026Permanent certificateNABIL ISHACenergy_progress
11/10/2025Insulation placement and R valuesNABIL ISHACenergy_progress
11/10/2025Structural Stability – Alterations of existing buildingsNABIL ISHACspecial
02/05/2025Fire-Resistant Penetrations and JointsNABIL ISHACspecial
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026Q01176677-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01176677-I1Open ↗
▸DOB NOWRestrictive Declaration/Easement 11
08/13/2026Q01176677-I1Open ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature6
08/22/2026Q01176677-I1Open ↗
08/22/2026Q01176677-I1Open ↗
08/22/2026Q01176677-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/22/2026Q01176677-I1Open ↗
08/22/2026Q01176677-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01176677-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01176677-I1Open ↗
▸Other Documents2
▸DOB NOWFinal Survey1
08/21/2026Q01176677-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026Q01176677-I1Open ↗