Primarily 2 family with 1 store or office
1080 ROGERS AVENUE
BROOKLYN · East Flatbush-Erasmus · BIN 3119116
💬 Discuss this project
1930Year Built
3Stories
S2Building Class
R6Zoning
3,000 sfGross Floor Area
3Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: 1080 ROGERS LLC · 2,000 sf lot · 1.5 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneralOther
Roof31p · 2 filings · 20 docs
Floor 519p · 1 filing · 20 docs
Floor 428p · 1 filing · 20 docs
Floor 332p · 1 filing · 20 docs
Floor 228p · 1 filing · 20 docs
Floor 123p · 1 filing · 20 docs
Cellar33p · 1 filing · 20 docs
Site & exterior19p · 2 filings · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SMART CONSULTING NY204/09/2026
APEX GROUP NY1004/09/2026
SMART CONSULTING NY.CORP203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/04/2024$875K—Private party → 1080 ROGERS LLC$292/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC210/06/2025
RIMKUS308/16/2025
JRS CONSULTING206/20/2025
SIMON JIANG106/10/2025
GRID DRAFTING AND CONSULTING LLC105/29/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMG GROUP USA503/21/2026
ADVANCED BUILDERS SERVICES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ABOVE BUILDER GROUP LLCGeneral Contractor904/09/2026
APEX GROUP NY CORPGeneral Contractor304/09/2026
DAVRY ELECTRIC INCElectrical103/22/2026
RIGHTWAY PLBG AND HTG INCFire Protection107/08/2026
TRISTATE FIRE SPRINK INCFire Protection107/08/2026
BEST MECHANICAL SVCS INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHAHRISH SHUVO ENGINEERIN8524510/06/2025
Building Lifecycle
All (126)Filed (9)Permit Issued (12)Signed Off (7)Violation (35)Inspection (9)Objection (24)Special Inspection (30)
07/27/2026
Signed off — Alteration CO
Structural plans filed in conjunction with Alt-co job #B01099843-S3
B01099843-I1
04/01/2026
Signed off — Alteration CO
Structural plans filed in conjunction with Alt-co job #B01099843-S3
B01099843-S1
02/23/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/19/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/11/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/05/2026
Violation issued (FDNY_ORDER, closed)
01/21/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/20/2026
Objection resolved — Addressed
01/20/2026
Objection resolved — Addressed
01/19/2026
Signed off — Alteration
Filling for Construction Fence
B01186509-I1
01/06/2026
Objection resolved — Addressed
12/29/2025
Signed off — Alteration CO
Structural plans filed in conjunction with Alt-co job #B01099843-S3
B01099843-S2
12/29/2025
Signed off — Alteration CO
Structural plans filed in conjunction with Alt-co job #B01099843-S3
B01099843-S3
12/23/2025
Objection resolved — Addressed
12/23/2025
Objection resolved — Addressed
12/17/2025
Objection resolved — Addressed
12/15/2025
Signed off — Alteration
INSTALLATION OF HEAVY DUTY SIDEWALK SHED AND SUPPORTED SCAFFOLDING AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION. WORK SHALL COMPLY WITH CH. 33 OF THE 2022 BUILDING CODE.
B01249717-I1
12/15/2025
Signed off — Alteration
B01251492-I1
12/03/2025
Objection raised — Scope
11/20/2025
Objection resolved — Addressed
11/14/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
11/05/2025
Permit issued — Structural
B01099843-S3-ST
10/22/2025
Permit issued — General Construction
B01099843-I1-GC-CX
10/17/2025
Objection raised — Zoning
10/17/2025
Objection raised — Structural
10/17/2025
Objection raised — Structural
10/17/2025
Objection raised — Zoning
10/17/2025
Objection raised — Energy
10/17/2025
Objection raised — Structural
10/13/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/06/2025
Filed — Alteration CO
Structural plans filed in conjunction with Alt-co job #B01099843-S3
B01099843-P1
10/06/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Shahrish Shuvo
10/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
10/06/2025
Special inspection requirement — Sprayed fire-resistant materials
Shahrish Shuvo
10/06/2025
Special inspection requirement — Structural Cold-Formed Steel
Shahrish Shuvo
10/06/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
10/06/2025
Special inspection requirement — Structural Steel - Details
Shahrish Shuvo
10/06/2025
Special inspection requirement — Energy Code Compliance Inspections
Shahrish Shuvo
10/06/2025
Special inspection requirement — Final
Shahrish Shuvo
10/06/2025
Special inspection requirement — Fire-Resistance Rated Construction
Shahrish Shuvo
10/06/2025
Special inspection requirement — Preliminary
Shahrish Shuvo
10/06/2025
Special inspection requirement — Interior lighting power
Shahrish Shuvo
10/06/2025
Special inspection requirement — Air barrier - visual inspection
Shahrish Shuvo
10/06/2025
Special inspection requirement — Fenestration air leakage
Shahrish Shuvo
10/06/2025
Special inspection requirement — Lighting controls
Shahrish Shuvo
10/06/2025
Special inspection requirement — Fenestration areas
Shahrish Shuvo
10/06/2025
Special inspection requirement — Exterior lighting power
Shahrish Shuvo
10/06/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Shahrish Shuvo
10/06/2025
Special inspection requirement — Lighting in dwelling units
Shahrish Shuvo
10/06/2025
Special inspection requirement — Insulation placement and R values
Shahrish Shuvo
10/06/2025
Special inspection requirement — Metering
Shahrish Shuvo
10/06/2025
Special inspection requirement — Maintenance information
Shahrish Shuvo
09/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/12/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
09/12/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/20/2025
Permit issued — Plumbing
B01099843-S1-EW-SP
08/16/2025
Filed — Alteration
INSTALLATION OF HEAVY DUTY SIDEWALK SHED AND SUPPORTED SCAFFOLDING AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION. WORK SHALL COMPLY WITH CH. 33 OF THE 2022 BUILDING CODE.
B01249717-P1
08/14/2025
Violation issued (ECB, closed)
Construction
08/14/2025
Violation issued (ECB, closed)
Construction
08/14/2025
Violation issued (ECB, closed)
Construction
Latest 60 of 126 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offABOVE BUILDER GROUP LLC11/05/2025
DOB NOWGeneral ConstructionPermit IssuedABOVE BUILDER GROUP LLC10/22/2025
DOB NOWPlumbingSigned-offTRISTATE FIRE SPRINK INC08/20/2025
DOB NOWSprinklersSigned-offBEST MECHANICAL SVCS INC08/11/2025
DOB NOWSprinklersSigned-offRIGHTWAY PLBG AND HTG INC08/11/2025
DOB NOWMechanical SystemsSigned-offABOVE BUILDER GROUP LLC07/23/2025
DOB NOWProtection and Mechanical MethodsSigned-offAPEX GROUP NY CORP07/09/2025
DOB NOWSupported ScaffoldSigned-offAPEX GROUP NY CORP07/07/2025
DOB NOWSupported ScaffoldSigned-offAPEX GROUP NY CORP07/07/2025
DOB NOWStructuralSigned-offABOVE BUILDER GROUP LLC07/03/2025
DOB NOWGeneral ConstructionPermit IssuedABOVE BUILDER GROUP LLC06/20/2025
DOB NOWConstruction FenceSigned-offABOVE BUILDER GROUP LLC06/17/2025
1 project · most recent 10/06/2025
Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/06/2025Signed-offABOVE BUILDER GROUP LLCHeating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Heat / Cool
Tosot TWH18AG25A2DI 18,000 BTU · Heat Pump Outdoor ×10
TWH09AC25A2DI 9,100 BTU · Split System ×6
TWH12AG25A2DI 12,000 BTU · Fan Coil Indoor ×1
Daikin Daikin -4MXS36WMVJU9 23,200 BTU · Heat Pump Outdoor ×6
Daikin -4MXM36AVJU9 34,000 BTU · Heat Pump Outdoor ×1
Daikin -RXF18AXVJU 18,000 BTU · Heat Pump Outdoor ×1
Daikin 4MXM36AVJU9 28,400 BTU · Condensing Unit ×1
Heating
Berko VFK404F 10,230 BTU · Fan Coil Indoor ×3
Ventilation
Broan A-80 80 CFM · Exhaust Fan ×2
696N 50 CFM · Exhaust Fan ×1
BUEZ230BL 75 CFM · Exhaust Fan ×1
Greenheck G-095-VG 600 CFM · Exhaust Fan ×2
__Junk__ ACD 24 1 BTU ×1
1 project · most recent 10/06/2025
Sprinkler System
FiledStatusContractorScope
10/06/2025Signed-offTRISTATE FIRE SPRINK INCSprinkler System
1 project · most recent 10/06/2025
Storm Water/Sanitary
FiledStatusContractorScope
10/06/2025Signed-offBEST MECHANICAL SVCS INCStorm, Water/Sanitary
3 projects · most recent 07/09/2026
General Wiring
FiledStatusContractorScope
07/09/2026CompleteDAVRY ELECTRIC INCGeneral Wiring
07/06/2025CompleteDAVRY ELECTRIC INC—
07/01/2025CompleteHIGH QUALITY ELEC.OF NYC—
1 project · most recent 10/06/2025
Steel Wood
FiledStatusContractorScope
10/06/2025Signed-offABOVE BUILDER GROUP LLCSteel, Wood
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
02/23/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/19/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/11/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/21/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/14/2025Fail-Final CND-Occupancy InspectionFailView ↗
10/13/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/19/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/12/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
09/12/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 30
DateRequirementInspectorRole
10/06/2025Exterior Insulation and Finish Systems (EIFS)Shahrish Shuvospecial
10/06/2025Fire-Resistant Penetrations and JointsShahrish Shuvospecial
10/06/2025Sprayed fire-resistant materialsShahrish Shuvospecial
10/06/2025Structural Cold-Formed SteelShahrish Shuvospecial
10/06/2025Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
10/06/2025Structural Steel - DetailsShahrish Shuvospecial
10/06/2025Energy Code Compliance InspectionsShahrish Shuvoprogress
10/06/2025FinalShahrish Shuvoprogress
10/06/2025Fire-Resistance Rated ConstructionShahrish Shuvoprogress
10/06/2025PreliminaryShahrish Shuvoprogress
10/06/2025Interior lighting powerShahrish Shuvoenergy_progress
10/06/2025Air barrier - visual inspectionShahrish Shuvoenergy_progress
10/06/2025Fenestration air leakageShahrish Shuvoenergy_progress
10/06/2025Lighting controlsShahrish Shuvoenergy_progress
10/06/2025Fenestration areasShahrish Shuvoenergy_progress
10/06/2025Exterior lighting powerShahrish Shuvoenergy_progress
10/06/2025Fenestration and door U-factor and product ratingsShahrish Shuvoenergy_progress
10/06/2025Lighting in dwelling unitsShahrish Shuvoenergy_progress
10/06/2025Insulation placement and R valuesShahrish Shuvoenergy_progress
10/06/2025MeteringShahrish Shuvoenergy_progress
10/06/2025Maintenance informationShahrish Shuvoenergy_progress
06/12/2025Shutoff dampersShahrish Shuvoenergy_progress
06/12/2025HVAC-R and service water heating equipmentShahrish Shuvoenergy_progress
06/12/2025Maintenance informationShahrish Shuvoenergy_progress
06/12/2025Fire-Resistant Penetrations and JointsShahrish Shuvospecial
Latest 25 of 30.
▾Documents — 51 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/21/2026B01186509-I1Request digital key ↗
08/21/2026B01099843-I1Request digital key ↗
08/21/2026B01099843-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026B01099843-P1Open ↗
08/13/2026B01099843-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026B01099843-I1Open ↗
08/13/2026B01099843-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/13/2026B01099843-I1Open ↗
08/13/2026B01099843-P1Open ↗
▸Seals & Professional Certifications17
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/21/2026B01099843-I1Open ↗
08/21/2026B01099843-P1Open ↗
08/21/2026B01099843-S3Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/23/2026B01099843-S2Open ↗
09/23/2026B01099843-S2Open ↗
08/28/2026B01099843-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026B01099843-S2Open ↗
08/28/2026B01099843-P1Open ↗
08/28/2026B01099843-P1Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist2
08/13/2026B01099843-P1Open ↗
08/13/2026B01099843-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B01099843-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B01099843-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/21/2026B01099843-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/21/2026B01099843-P1Open ↗
08/21/2026B01099843-S3Open ↗
08/21/2026B01099843-S2Open ↗
Showing 3 of 5 on file for this type
▸Other Documents9
▸DOB NOWPlot Diagram2
08/13/2026B01099843-I1Open ↗
08/13/2026B01099843-P1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026B01099843-I1Open ↗
08/13/2026B01099843-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B01099843-I1Open ↗
08/13/2026B01099843-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/21/2026B01099843-I1Open ↗
08/21/2026B01099843-P1Open ↗
▸DOB NOWFinal Survey1
08/21/2026B01099843-I1Open ↗