← Back
Two stories - detached, small or mid-size
109-32 PARK LANE SOUTH
QUEENS · Richmond Hill · BIN 4192258
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R2Zoning
2,084 sfGross Floor Area
1Units
2 Open Violations 0 unresolved · 2 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · 3,500 sf lot · 0.6 FAR built · Flood zone X
Locations of Work
Architecture
Floor 11p · 1 filing · 10 docs
Site & exterior1p · 1 filing · 10 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SUNG HO SHIN ARCHITECT, PC105/27/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
G-BROTHERS CONTRACTING COGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SUNG HO SHIN ARCHITECT2997105/27/2021
Building Lifecycle
All (13)Filed (1)Permit Issued (1)Signed Off (1)Violation (3)Inspection (1)Special Inspection (6)
11/12/2021
Signed off — Alteration
INSTALL EXTERIOR DOOR, STOOP, AND STAIR TO HAVE ACCESS FROM EXISTING KITCHEN TO REAR YARD. NO CHANGE IN USE, OCCUPANCY, OR EGRESS IS INVOLVED UNDER THIS APPLICATION.
Q00529350-I1
10/20/2021
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/24/2021
Permit issued — General Construction
Q00529350-I1-GC
05/27/2021
Filed — Alteration
INSTALL EXTERIOR DOOR, STOOP, AND STAIR TO HAVE ACCESS FROM EXISTING KITCHEN TO REAR YARD. NO CHANGE IN USE, OCCUPANCY, OR EGRESS IS INVOLVED UNDER THIS APPLICATION.
Q00529350-I1
05/26/2021
Special inspection requirement — Concrete - Cast-In-Place
SUNG HO SHIN
05/26/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
SUNG HO SHIN
05/26/2021
Special inspection requirement — Energy Code Compliance Inspections
SUNG HO SHIN
05/26/2021
Special inspection requirement — Fenestration air leakage
SUNG HO SHIN
05/26/2021
Special inspection requirement — Fenestration areas
SUNG HO SHIN
05/26/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
SUNG HO SHIN
09/05/1998
Violation issued (ECB, closed)
Quality of Life
09/05/1998
Violation issued (ECB, open)
Quality of Life
08/25/1998
Violation issued (ECB, open)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offG-BROTHERS CONTRACTING CO08/24/2021
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
10/20/2021Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
05/26/2021Concrete - Cast-In-PlaceSUNG HO SHINspecial
05/26/2021Fire-Resistant Penetrations and JointsSUNG HO SHINspecial
05/26/2021Energy Code Compliance InspectionsSUNG HO SHINprogress
05/26/2021Fenestration air leakageSUNG HO SHINenergy_progress
05/26/2021Fenestration areasSUNG HO SHINenergy_progress
05/26/2021Fenestration and door U-factor and product ratingsSUNG HO SHINenergy_progress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/27/2026Q00529350-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature4
08/26/2026Q00529350-I1Open ↗
08/26/2026Q00529350-I1Open ↗
08/26/2026Q00529350-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026Q00529350-I1Open ↗
08/26/2026Q00529350-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/27/2026Q00529350-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/27/2026Q00529350-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00529350-I1Open ↗