← Back
Two stories - detached, small or mid-size
109-40 135 STREET
QUEENS · South Ozone Park · BIN 4250056
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R3-2Zoning
1,470 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 2,500 sf lot · 0.59 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/25/2019$600K—Private party → Private party$408/sf building
05/10/2018$410K—Private party → Private party$279/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALL CITY ENGINEERING PC110/19/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BEYOND COOLING LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALL CITY ENGINEERING PC7115110/19/2021
Building Lifecycle
All (13)Filed (1)Permit Issued (1)Violation (2)Objection (2)Special Inspection (7)
01/19/2024
Violation issued (ECB, closed)
Construction
12/29/2021
Permit issued — Mechanical Systems
Q00612781-I1-MS
10/22/2021
Objection raised — Other
10/22/2021
Objection resolved — Addressed
10/19/2021
Filed — Alteration
Install new AC condenser for single family house, no change in use egress or occupancy.
Q00612781-I1
10/15/2021
Special inspection requirement — Mechanical Systems
ZHAO DENG
10/15/2021
Special inspection requirement — Final
ZHAO DENG
10/15/2021
Special inspection requirement — Energy Code Compliance Inspections
ZHAO DENG
10/15/2021
Special inspection requirement — HVAC-R and service water heating equipment
ZHAO DENG
10/15/2021
Special inspection requirement — Maintenance information
ZHAO DENG
10/15/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
ZHAO DENG
10/15/2021
Special inspection requirement — HVAC-R and service water heating system controls
ZHAO DENG
06/01/2021
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offBEYOND COOLING LLC12/29/2021
1 project · most recent 10/19/2021
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
10/19/2021Signed-offBEYOND COOLING LLCAir Conditioning Systems
Cooling
Gree MULTI30HP230V1CO 28,400 BTU · Heat Pump Outdoor ×1
MULTI36HP230V1CO 34,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 06/14/2023
HVAC Wiring
FiledStatusContractorScope
06/14/2023CompletePURCELL ELEC'L CONTRS LTDHVAC Wiring
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
10/15/2021Mechanical SystemsZHAO DENGspecial
10/15/2021FinalZHAO DENGprogress
10/15/2021Energy Code Compliance InspectionsZHAO DENGprogress
10/15/2021HVAC-R and service water heating equipmentZHAO DENGenergy_progress
10/15/2021Maintenance informationZHAO DENGenergy_progress
10/15/2021HVAC-R and service water piping design and insulationZHAO DENGenergy_progress
10/15/2021HVAC-R and service water heating system controlsZHAO DENGenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026Q00612781-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026Q00612781-I1Open ↗
09/01/2026Q00612781-I1Open ↗
09/01/2026Q00612781-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/27/2026Q00612781-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026Q00612781-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/15/2026Q00612781-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00612781-I1Open ↗